Brand: ABB
ABB ACS880-01-169A-3 Wall-Mounted Drive 90 kW 169 A
Description
What the ACS880-01-169A-3 is
The ACS880-01-169A-3 is an ABB ACS880-01 wall-mounted single drive for 380 to 415 V supplies. The power stage delivers 169 A (90 kW typical motor power) in frame R7. Typical jobs are large process fans and pumps and main drives of heavy machinery. Direct torque control, a built-in harmonic choke and Safe Torque Off come with the drive, which keeps the surrounding cabinet simple.
Technical specifications
| Parameter | Specification |
|---|---|
| Type designation | ACS880-01-169A-3 |
| Product family | ACS880 industrial drives, -01 = wall-mounted single drive |
| Supply voltage | 3-phase 380 to 415 V (400 V table) |
| Nominal rating | 90 kW, 169 A |
| Heavy-duty use | 75 kW, 145 A |
| Maximum output current | 247 A |
| Frame size | R7 |
| IP21 height, width, depth, weight | 880 mm with cable box (600 mm without), 284 mm, 365 mm, 53 kg |
| IP55 size (H x W x D) | 880 x 284 x 423 mm; 54 kg |
| Sound level | 67 dB(A) |
| Heat dissipation | 2042 W |
| Cooling air flow | 450 m3/h |
| Brake chopper | A selectable internal option, order code +D150 |
| Standard brake resistor | SAFUR125F500 (4 ohm, 3600 kJ, 9 kW continuous) |
| Minimum brake resistance | 3.3 ohm for 90 kW braking power |
| Sine filter type | B84143V0162S229 (rated 153 A) |
Sizing and installing the ACS880-01-169A-3
Two duty classes apply: light overload at 161 A and 90 kW, heavy duty at 145 A and 75 kW. Maximum output current is 247 A. Choose light overload for variable-torque loads such as pumps and fans, and heavy duty for constant-torque machines with high breakaway torque. Always size from the motor nameplate current at your voltage and check the ambient temperature and altitude against the hardware manual.
Wall space needed for IP21 is 284 mm by 880 mm (cable box included), 365 mm deep, with a weight of 53 kg. The IP55 version for dusty and wet places is 880 x 284 x 423 mm and 54 kg. The drive loses about 2042 W, needs 450 m3/h of cooling air and runs at 67 dB(A).
Braking, filters and options
For braking, the chopper is a selectable internal option, order code +D150. ABB lists the SAFUR125F500 resistor of 4 ohm and 3600 kJ at 90 kW, and a minimum resistance of 3.3 ohm. Order +E202 for a C2 filter, +E200 for C3 or +E201 for IT networks; the standard drive meets C4 on grounded networks. For long cables, submersible pumps or noise reduction, ABB lists the B84143V0162S229 sine filter (153 A, 75 kW).
The ZCU control unit provides 6 digital inputs, 2 digital inputs/outputs, 2 analog inputs, 2 analog outputs, 3 relay outputs, STO and an isolated RS485 port. Three option slots take fieldbus adapters, I/O extensions, feedback modules and a safety functions module.
Related ABB products: ABB ACQ580-01-062A-4 Water Drive 30 kW 62 A, ABB ACS580-01-106A-4 AC Drive 55 kW 106 A, ABB ACQ580-01-206A-4 Water Drive 110 kW 206 A, ABB ACQ580-01-363A-4 Water Drive 200 kW 363 A, ABB ACQ580-01-490A-4 Water Drive 250 kW 490 A and ABB ACS580-01-062A-4 AC Drive 30 kW 62 A.
Documents and quotation
The ratings, dimensions, brake and filter data were read from the ACS880 single drives catalogue 3AUA0000098111, which is linked, and ABB’s page for the ACS880-01-169A-3. To request the ACS880-01-169A-3, send Seven Star LLC your motor data and supply details; availability comes with the quotation. Before ordering, check the full type code with options, the motor rating, enclosure, filters, braking duty and site conditions. Other sizes are listed in AC drives, and a smaller general purpose family is on the ABB ACS580 page.
Datasheets & Documents
- Catalog ABB ACS880 single drives catalog (3AUA0000098111) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
Related products
Frequently Asked Questions
ABB lists 169 A nominal (90 kW), 161 A (90 kW) for light overload, 145 A (75 kW) for heavy duty and 247 A maximum output current.
It is frame R7: 880 mm high with cable entry box, 284 mm wide, 365 mm deep and 53 kg; the IP55 version is 880 x 284 x 423 mm and 54 kg.
The brake chopper is a selectable internal option, order code +D150; the catalogue lists SAFUR125F500 (4 ohm) and a minimum resistance of 3.3 ohm.
The catalogue gives 2042 W of heat dissipation, 450 m3/h of air flow and 67 dB(A) noise.
The catalogue lists +E202 for C2, +E200 for C3 and +E201 for ungrounded networks; category C4 is standard on 380 to 500 V ACS880-01 drives.