Danfoss AB-QM Pressure Independent Control Valve (PICV) DN 15-250
Description
Overview
The Danfoss AB-QM is a pressure independent control valve (PICV) that combines two functions in one body: a differential pressure controller and a control valve with an adjustable flow limiter. The built-in pressure controller keeps the differential pressure across the control part constant, so the valve always has full authority and automatically limits flow to the value set on the dial. Fitted with an actuator, it controls temperature at terminal units such as fan coils, air handling units, chilled beams, induction units and heat exchangers; without an actuator, it acts as an automatic flow limiter. The range covers DN 15 to DN 250, for flows from 200 l/h up to 500 m³/h.
Seven Star LLC supplies the Danfoss AB-QM, its actuators and installation accessories to MEP contractors, consultants and facility managers across Oman and the GCC, with engineering support in Muscat. In chilled water systems, which carry most of the cooling load in Gulf buildings, poor hydronic balance shows up as overflowing terminal units near the pump, starved units at the end of the line, low delta-T at the chillers and more pumps running than designed. A correctly sized PICV addresses all of these at source.
Operating Principle
Inside the valve, a diaphragm-operated pressure controller senses the pressure before and after the control cone and adjusts its own opening to hold that differential constant. Whatever the pump head or the opening and closing of other circuits, the pressure drop across the control valve therefore stays the same, and the flow through the Danfoss AB-QM depends only on the stroke position set by the actuator and on the maximum flow preset on the dial. The control part has a linear characteristic, which an actuator such as NovoCon S or AME 110 can convert to equal percentage for water-to-air applications.
Because the valve limits flow on its own, a system built with Danfoss AB-QM valves is balanced at every load, not only at full design load. Danfoss specifies a control range of 1:1000, and regardless of the setting the valve can modulate below 1 % of set flow. At the minimum differential pressure, the valve reaches at least 90 % of nominal flow. The practical consequences are stable room temperature with minimal hysteresis, no hunting at part load, and pumping energy that matches the actual demand.
Engineering Design of the Danfoss AB-QM
Threaded Danfoss AB-QM 4.0 valves from DN 15 LF to DN 32 HF have DZR brass bodies, EPDM membranes and O-rings, PPSU guide parts and stainless steel springs, with a 4 mm stroke and PN 25 rating. They are available with external thread to ISO 228/1 (G¾A to G1½A) or internal thread to ISO 7/1 (Rp½ to Rp1¼), and with or without test plugs. Threaded DN 40 and DN 50 and all flanged sizes use grey iron EN-GJL-250 bodies, PN 16 rating and longer strokes of 10 to 36 mm. Flanged connections follow EN 1092-2.
The flow setting of the Danfoss AB-QM is always visible on the valve, and the test plugs allow the actual flow to be verified with a measuring instrument during commissioning or troubleshooting. Medium temperature is +2 to +95 °C for DN 15 to 32 and +2 to +120 °C for larger sizes, with operation down to -20 °C possible when the spindle is protected by vapour-tight insulation. Danfoss tested the valves with 50 % ethylene and propylene glycol, and the AB-QM 4.0 range has EPP insulation shells available for DN 15 to 32.
Key Features
The Danfoss AB-QM brings control and balancing together in one component:
- Integrated differential pressure controller gives 100 % valve authority at every load.
- Automatic flow limitation removes the need for separate static balancing valves.
- Sizes from DN 15 LF to DN 250 HF, with nominal flows from 200 l/h to 500,000 l/h.
- Setting range of 10 to 100 % on AB-QM 4.0 threaded valves and 40 to 100 % on DN 40 and above, with the setting always visible.
- Test plugs on the AB-QM 4.0 for on-site flow verification.
- Linear characteristic with a control range of 1:1000 and modulation below 1 % of set flow.
- Leakage class IV to IEC 60534-4 with recommended actuators on threaded DN 15 to 32, and shut-off to ISO 5208 class A.
- Compatible with the NovoCon S digital actuator for BACnet or Modbus control and data.
Industrial Applications
The Danfoss AB-QM is specified for the chilled water side of commercial towers, hotels, hospitals, malls, universities and government buildings, where hundreds of fan coil units and air handling units must each receive their design flow. In Muscat and across the GCC, many of these buildings are connected to district cooling plants that charge for low delta-T, so the ability of a PICV to stop overflow at part load has a direct cost impact. Data centres and pharmaceutical facilities use the same valves on precision cooling coils that need stable flow regardless of other loads.
For larger plant applications, flanged Danfoss AB-QM valves up to DN 250 regulate flow to chillers, secondary heat exchangers and energy transfer stations. Seven Star LLC supplies the Danfoss AB-QM together with matching actuators, union and welding tailpieces, and the official data sheet, and can help translate a terminal unit schedule into valve sizes and flow settings for projects in Muscat, Sohar, Duqm and Salalah.
Technical Specifications
The data below for the Danfoss AB-QM is taken from the Danfoss data sheet AI309581732428en-030601 (2026.01):
| Parameter | Specification |
|---|---|
| Model | Danfoss AB-QM 4.0 (threaded DN 15-32) and AB-QM (DN 40-250) |
| Nominal flow | 200 l/h (DN 15 LF) to 500,000 l/h (DN 250 HF) |
| Setting range | 10-100 % (AB-QM 4.0 DN 15-32); 40-100 % (DN 40-250) |
| Differential pressure | Δp min 16 to 60 kPa by size; Δp max 600 kPa (DN 15-100), 800 kPa (DN 125-250) |
| Pressure stage | PN 25 (DN 15-32 threaded); PN 16 (DN 40-250) |
| Control characteristic | Linear, convertible to equal percentage by actuator; control range 1:1000 |
| Medium temperature | +2 to +95 °C (DN 15-32); +2 to +120 °C (DN 40-250) |
| Connections | External thread ISO 228/1, internal thread ISO 7/1, flanges EN 1092-2 |
| Body material | DZR brass (DN 15-32); grey iron EN-GJL-250 (DN 40-250) |
| Stroke | 4 mm (DN 15-32) to 36 mm (DN 200-250) |
| Medium | Water and water mixtures for closed heating and cooling systems |
How to Order
To request a quotation for the Danfoss AB-QM, send Seven Star LLC the terminal unit schedule with design flows, pipe sizes, available differential pressure, control signal or BMS protocol and preferred connection type. Our Muscat team will confirm valve sizes and actuators, advise on stock and lead time for Oman and the GCC, and provide the official Danfoss data sheet. Other Danfoss products on our site include the Danfoss MBS 3000 pressure transmitter and the Danfoss VLT AutomationDrive FC 302, and chilled water energy can be measured with the pFlow E5 ultrasonic energy meter.
Related buying guides: Valves supplier in Oman for MEP projects: chilled water, plumbing and fire protection valves; PICV supplier in Oman: pressure independent control valves and FCU valve kits.
Datasheets & Documents
- Datasheet Danfoss AB-QM 4.0 / AB-QM PICV DN 15-250 Data Sheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Frequently requested Danfoss models: Danfoss 132B0101 VLT Control Panel LCP 12, Danfoss VLT AutomationDrive FC 302 Variable Frequency Drive, Danfoss MBS 3000 General Purpose Pressure Transmitter, Danfoss EVR 25 Servo-Operated Solenoid Valve, Danfoss ICV Pilot-Operated Industrial Refrigeration Valve.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
FAQ
Questions about the Danfoss AB-QM Pressure Independent Control Valve
Answers from our engineering team on installation, compatibility and integration.
01Why use a Danfoss AB-QM instead of a two-way valve with a separate balancing valve?
The AB-QM contains a differential pressure controller that keeps the pressure across its control part constant, so the valve has full authority and limits flow to the set value whatever happens elsewhere in the system. This removes the need for separate static balancing valves and the commissioning time spent adjusting them, and it prevents overflow at terminal units that wastes pumping energy.
02What sizes and flows does the Danfoss AB-QM range cover?
Threaded valves run from DN 15 LF (200 l/h) to DN 50 (12,500 l/h) with external ISO 228/1 or internal ISO 7/1 threads. Flanged valves to EN 1092-2 PN 16 run from DN 50 to DN 250 HF, with a nominal flow of up to 500,000 l/h, which is 500 m³/h.
03What differential pressure does the Danfoss AB-QM need to work correctly?
Each size has a minimum differential pressure, from 16 kPa on the small threaded valves to 60 kPa on the high-flow flanged versions, at which it reaches at least 90 percent of nominal flow. The maximum is 600 kPa for DN 15 to 100 and 800 kPa for DN 125 to 250. The pump and index circuit should be designed to provide at least the minimum value at the most remote valve.
04Which actuators can drive the Danfoss AB-QM?
For DN 15 to 32 the data sheet lists the NovoCon S digital actuator with BACnet MS/TP or Modbus RTU, the AME 110 NL and NLX modulating actuators, AMV 110/120 three-point actuators, AME 13 spring-return actuators, AME 113 actuators with battery safety function, and ABNM and TWA-Q thermal actuators. Larger sizes use NovoCon M or AME 435 QM and the corresponding larger actuators.
05Can Seven Star LLC supply Danfoss AB-QM valves for a chilled water project in Oman?
Seven Star LLC supplies Danfoss AB-QM valves, actuators and accessories to MEP contractors and facility owners in Oman and the GCC. We help select valve size and flow setting from the terminal unit schedule, and provide the official data sheet and support from Muscat.