Brand: Schneider Electric
Schneider Electric RSB1A160P7 Harmony RSB 16 A Interface Relay
Description
RSB1A160P7 interface relay, 1 CO, 16 A, 230 V AC coil
The RSB1A160P7 is a Schneider Electric product listed in the datasheet as: interface plug-in relay, Harmony electromechanical relays, 16A, 1CO, 230V AC distribution facility. The RSB1A160P7 is a Harmony interface plug-in relay with one changeover contact at 16 A and a 230 V AC coil. Its one-pole, high-current design fits loads such as heaters, small contactors and solenoids. Seven Star LLC supplies the RSB1A160P7 in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference: RSB is the interface relay series, 1 the one contact, A160 the 16 A version, P7 the 230 V AC coil.
Technical specifications of the RSB1A160P7
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / RSB1A160P7 |
| Description | interface plug-in relay, Harmony electromechanical relays, 16A, 1CO, 230V AC distribution facility |
| Range of Product | Harmony Electromechanical Relays |
| Series name | RSB series |
| Product or Component Type | Plug-in relay |
| Relay Type | Interface relay |
| Contacts type and composition | 1 C/O |
| Status LED | Without |
| [Uc] control circuit voltage | 230 V AC 50/60 Hz |
| Control Type | Without lockable test button |
| [Ithe] conventional enclosed | 16 A -40 to 40 °C |
| Average resistance | 33000 Ohm AC 20 °C ± 10 % |
| [Ue] rated operational voltage | 184 to 345 V AC 50/60 Hz |
| [Uimp] rated impulse withstand | 3.6 kV IEC 61000-4-5 |
| [Ie] rated operational current | 16 A AC-1/DC-1 NO IEC; 8 A AC-1/DC-1 NC IEC |
| [Ui] rated insulation voltage | 400 V IEC 60947 |
| Maximum switching voltage | 300 V DC IEC |
| Drop-out voltage threshold | >= 0.15 Uc AC |
| Load current | 16 A 250 V AC; 16 A 28 V DC |
| minimum switching current | 10 mA |
| Maximum switching capacity | 4000 VA/448 W |
| minimum switching voltage | 12 V |
| Minimum switching capacity | 120 mW 10 mA, 12 V |
| Operating time | 20 ms operating; 20 ms reset |
| Mechanical durability | 10000000 cycles |
| Electrical durability | 100000 cycles, 16 A at 250 V, AC-1 NO; 100000 cycles, 8 A at 250 V, AC-1 NC |
| Safety reliability data | B10d = 100000 |
| Operating rate | <= 600 cycles/hour under load; <= 18000 cycles/hour no-load |
| Average coil consumption | 0.75 VA AC |
| Removable legend | Without |
| Protection category | RT I |
| Operating position | Any position |
| Test levels | Level A group mounting |
| Contacts material | Silver alloy (AgNi) |
| Shape of pin | Flat (PCB type) |
| Net Weight | 0.014 kg |
| Compatibility code | RSB |
| Dielectric strength | 1000 V AC between contacts; 2500 V AC between poles; 5000 V AC between coil and contact |
| Vibration resistance | ± 1 mm (f= 10 to 55 Hz) conforming to IEC 60068-2-6 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| Ambient air temperature (operation or storage, as listed) | -40 to 70 °C AC |
| Standards | IEC 61810-1; CSA C22.2 No 14; UL 508 |
Single heavy contact data of the RSB1A160P7
Rated operational voltage: 184 to 345 V AC 50/60 Hz. Rated operational current: 16 A AC-1/DC-1 NO IEC; 8 A AC-1/DC-1 NC IEC. Coil or control voltage: 230 V AC 50/60 Hz. Contacts: 1 C/O. Mechanical durability: 10000000 cycles. Electrical durability: 100000 cycles, 16 A at 250 V, AC-1 NO; 100000 cycles, 8 A at 250 V, AC-1 NC.
One 16 A contact is a good fit for a heater or a solenoid. The datasheet lists switching capacity and the minimum load, which matters for low-current signals.
Compared with RXM relays and the RSB1A160P7
RXM relays have more poles but lower ratings. RSB relays with one pole carry a larger current. Pick RSB for a heavy single load and RXM for multi-signal interfacing.
Selection checklist for the RSB1A160P7
- One C/O contact, 16 A.
- Coil: 230 V AC.
- Socket.
- Load type.
- Contact life.
- Mounting.
Fitting and care of the RSB1A160P7
Seat in the socket, secure with the clip and test with the load disconnected. Ensure the load current does not exceed the rating.
Check contact wear on heavy loads.
Typical applications of the RSB1A160P7 in Oman and the GCC
In Oman and the GCC it serves in heater control, small valve solenoids and as a contact multiplier in AC panels.
Dimensions, environment and approvals of the RSB1A160P7
The RSB1A160P7 weighs 0.014 kg. Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.
Ambient temperature limits in the datasheet: -40 to 70 °C AC. Ingress protection: IP40 conforming to IEC 60529. Vibration resistance: ± 1 mm (f= 10 to 55 Hz) conforming to IEC 60068-2-6. Shock resistance: 10 gn 11 ms not operating IEC 60068-2-27; 5 gn 11 ms in operation IEC 60068-2-27. Standards listed: IEC 61810-1; CSA C22.2 No 14; UL 508. Certifications listed for this reference: UL; CSA; EAC.
For loads near the 16 A limit of the RSB1A160P7, the quality of the socket and cable is as important as the relay. A socket with screw terminals rated for 16 A and a cable of adequate cross-section prevent heating at the connection, which is a more common cause of failure than the relay itself. Check the inrush of the load: lamps, capacitive loads and some power supplies draw many times their rated current at switch-on and weld contacts if the relay is chosen only by steady current. If the load is an electric heater, the relay is well suited, but with frequent switching a solid-state alternative may last longer. Where the relay is controlled from a 230 V AC supply, take care with the touch hazard on the coil terminals and use finger-safe sockets. Always keep a clean, dry cabinet; humidity and salt dust in coastal plants corrode relay pins faster than the rated life suggests.
Information to send with an RFQ for the RSB1A160P7
- Full reference and quantity required
- Existing equipment, panel or rack it must fit
- Supply voltage, load or signal details of the application
- Required delivery location and timing
- Whether a spare, a replacement or a new installation
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.
Datasheets & Documents
- Datasheet Schneider Electric RSB1A160P7 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric RSB1A160P7 Harmony RSB 16 A
Answers from our engineering team on installation, compatibility and integration.
01What is the net weight of the RSB1A160P7?
The datasheet gives 0.014 kg.
02What ingress protection does the RSB1A160P7 list?
Stated as IP40 conforming to IEC 60529.
03Which standards does the RSB1A160P7 list?
Listed: IEC 61810-1; CSA C22.2 No 14; UL 508.
04Which product range does the RSB1A160P7 belong to?
The datasheet lists the range as Harmony Electromechanical Relays.
05What mechanical durability does the RSB1A160P7 list?
Stated as 10000000 cycles.