Schneider Electric RSB1A160P7 Harmony RSB 16 A Interface Relay

Description

RSB1A160P7 interface relay, 1 CO, 16 A, 230 V AC coil

The RSB1A160P7 is a Schneider Electric product listed in the datasheet as: interface plug-in relay, Harmony electromechanical relays, 16A, 1CO, 230V AC distribution facility. The RSB1A160P7 is a Harmony interface plug-in relay with one changeover contact at 16 A and a 230 V AC coil. Its one-pole, high-current design fits loads such as heaters, small contactors and solenoids. Seven Star LLC supplies the RSB1A160P7 in Oman and the GCC as an independent supplier based in Muscat.

Reading the reference: RSB is the interface relay series, 1 the one contact, A160 the 16 A version, P7 the 230 V AC coil.

Technical specifications of the RSB1A160P7

Parameter Specification
Manufacturer / part number Schneider Electric / RSB1A160P7
Description interface plug-in relay, Harmony electromechanical relays, 16A, 1CO, 230V AC distribution facility
Range of Product Harmony Electromechanical Relays
Series name RSB series
Product or Component Type Plug-in relay
Relay Type Interface relay
Contacts type and composition 1 C/O
Status LED Without
[Uc] control circuit voltage 230 V AC 50/60 Hz
Control Type Without lockable test button
[Ithe] conventional enclosed 16 A -40 to 40 °C
Average resistance 33000 Ohm AC 20 °C ± 10 %
[Ue] rated operational voltage 184 to 345 V AC 50/60 Hz
[Uimp] rated impulse withstand 3.6 kV IEC 61000-4-5
[Ie] rated operational current 16 A AC-1/DC-1 NO IEC; 8 A AC-1/DC-1 NC IEC
[Ui] rated insulation voltage 400 V IEC 60947
Maximum switching voltage 300 V DC IEC
Drop-out voltage threshold >= 0.15 Uc AC
Load current 16 A 250 V AC; 16 A 28 V DC
minimum switching current 10 mA
Maximum switching capacity 4000 VA/448 W
minimum switching voltage 12 V
Minimum switching capacity 120 mW 10 mA, 12 V
Operating time 20 ms operating; 20 ms reset
Mechanical durability 10000000 cycles
Electrical durability 100000 cycles, 16 A at 250 V, AC-1 NO; 100000 cycles, 8 A at 250 V, AC-1 NC
Safety reliability data B10d = 100000
Operating rate <= 600 cycles/hour under load; <= 18000 cycles/hour no-load
Average coil consumption 0.75 VA AC
Removable legend Without
Protection category RT I
Operating position Any position
Test levels Level A group mounting
Contacts material Silver alloy (AgNi)
Shape of pin Flat (PCB type)
Net Weight 0.014 kg
Compatibility code RSB
Dielectric strength 1000 V AC between contacts; 2500 V AC between poles; 5000 V AC between coil and contact
Vibration resistance ± 1 mm (f= 10 to 55 Hz) conforming to IEC 60068-2-6
IP degree of protection IP40 conforming to IEC 60529
Ambient air temperature (operation or storage, as listed) -40 to 70 °C AC
Standards IEC 61810-1; CSA C22.2 No 14; UL 508

Single heavy contact data of the RSB1A160P7

Rated operational voltage: 184 to 345 V AC 50/60 Hz. Rated operational current: 16 A AC-1/DC-1 NO IEC; 8 A AC-1/DC-1 NC IEC. Coil or control voltage: 230 V AC 50/60 Hz. Contacts: 1 C/O. Mechanical durability: 10000000 cycles. Electrical durability: 100000 cycles, 16 A at 250 V, AC-1 NO; 100000 cycles, 8 A at 250 V, AC-1 NC.

One 16 A contact is a good fit for a heater or a solenoid. The datasheet lists switching capacity and the minimum load, which matters for low-current signals.

Compared with RXM relays and the RSB1A160P7

RXM relays have more poles but lower ratings. RSB relays with one pole carry a larger current. Pick RSB for a heavy single load and RXM for multi-signal interfacing.

Selection checklist for the RSB1A160P7

  • One C/O contact, 16 A.
  • Coil: 230 V AC.
  • Socket.
  • Load type.
  • Contact life.
  • Mounting.

Fitting and care of the RSB1A160P7

Seat in the socket, secure with the clip and test with the load disconnected. Ensure the load current does not exceed the rating.

Check contact wear on heavy loads.

Typical applications of the RSB1A160P7 in Oman and the GCC

In Oman and the GCC it serves in heater control, small valve solenoids and as a contact multiplier in AC panels.

Dimensions, environment and approvals of the RSB1A160P7

The RSB1A160P7 weighs 0.014 kg. Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.

Ambient temperature limits in the datasheet: -40 to 70 °C AC. Ingress protection: IP40 conforming to IEC 60529. Vibration resistance: ± 1 mm (f= 10 to 55 Hz) conforming to IEC 60068-2-6. Shock resistance: 10 gn 11 ms not operating IEC 60068-2-27; 5 gn 11 ms in operation IEC 60068-2-27. Standards listed: IEC 61810-1; CSA C22.2 No 14; UL 508. Certifications listed for this reference: UL; CSA; EAC.

For loads near the 16 A limit of the RSB1A160P7, the quality of the socket and cable is as important as the relay. A socket with screw terminals rated for 16 A and a cable of adequate cross-section prevent heating at the connection, which is a more common cause of failure than the relay itself. Check the inrush of the load: lamps, capacitive loads and some power supplies draw many times their rated current at switch-on and weld contacts if the relay is chosen only by steady current. If the load is an electric heater, the relay is well suited, but with frequent switching a solid-state alternative may last longer. Where the relay is controlled from a 230 V AC supply, take care with the touch hazard on the coil terminals and use finger-safe sockets. Always keep a clean, dry cabinet; humidity and salt dust in coastal plants corrode relay pins faster than the rated life suggests.

Information to send with an RFQ for the RSB1A160P7

  • Full reference and quantity required
  • Existing equipment, panel or rack it must fit
  • Supply voltage, load or signal details of the application
  • Required delivery location and timing
  • Whether a spare, a replacement or a new installation

Documents and quotation

A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.

Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.

Datasheets & Documents
  • PDF Datasheet Schneider Electric RSB1A160P7 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric RSB1A160P7 Harmony RSB 16 A

Answers from our engineering team on installation, compatibility and integration.

01What is the net weight of the RSB1A160P7?
The datasheet gives 0.014 kg.
02What ingress protection does the RSB1A160P7 list?
Stated as IP40 conforming to IEC 60529.
03Which standards does the RSB1A160P7 list?
Listed: IEC 61810-1; CSA C22.2 No 14; UL 508.
04Which product range does the RSB1A160P7 belong to?
The datasheet lists the range as Harmony Electromechanical Relays.
05What mechanical durability does the RSB1A160P7 list?
Stated as 10000000 cycles.