- Automation & ControlView all 1,654 products
- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Industrial Computers
- Servo Drives
- Isolator & Barrier
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Automation Software
- Machine Vision
- Robotics
Brand: Lovato Electric
Lovato HS1C6HV025A230 25 A Solid State Relay with Heatsink
Description
A 25 A solid state relay supplied complete with heatsink
The HS1C6HV025A230 is a single-phase solid state relay with heatsink from the Lovato Electric HS1C series. It switches AC loads up to 25 A at 40 degC (derating to 22 A at 55 degC) at 48-600 VAC, using an SCR output with zero-crossing switching and a blocking voltage of 1200 V.
The control input is 90-280VAC (pick-up 45 V, drop-out 20 V). Because the relay is supplied already mounted on its heatsink, the thermal design is done: you do not need to calculate the heatsink resistance separately.
Technical specifications
| Parameter | Specification |
|---|---|
| Order code | HS1C6HV025A230 |
| Product designation | Solid state relay |
| Product type designation | HS1C |
| Type | single-phase |
| Control voltage | 90-280VAC |
| Operating voltage pick-up | 45 V |
| Operating voltage drop-out | 20 V |
| Input current at min…max voltage | 5-22 mA |
| Switching-on | Half cycle max |
| Switching-off | Half cycle max |
| Static output type | SCR (silicon controlled rectifier) |
| Switching mode | Zero crossing |
| Rated operating voltage | 48-600 VAC |
| Blocking voltage | 1200 V |
| Operational frequency (min…max) | 45-65 Hz |
| Rated operating current AC-51 (resistive load) at 40°C | 25 A |
| Rated operating current AC-51 (resistive load) at 55°C | 22 A |
| Operational current min | 0.165 A |
| Non repetitive surge peak on state current t=10ms | 520 A |
| Off state leakage current | 1 mA |
| On state output voltage drop | 1.2 V |
| Critical rate of rise of off-state voltage dv/dt | 1000 V/µs |
| Input – Output isolation | 5000 V |
| Input – Output to metal base | 5000 V |
| I2t | 1350 A2s |
| Control terminals | Screw Type |
| Terminals tool | Blade 3.5mm |
| Operating position, allowable | On vertical plane |
| Fixing | Screw or on 35mm DIN rail |
| Operating temperature (min) | -40 °C |
| Operating temperature (max) | +80 °C |
| Storage temperature (min) | -40 °C |
| Storage temperature (max) | +130 °C |
| Protection degree | IP20 (on front) |
Selecting the relay
Choose this code when you want a plug-and-play thermal package, for example in small heater panels. Non-heatsink versions (HS1B hockey-puck types) give higher currents but need a separate heatsink.
In the catalogue this A230 version has a 90-280 VAC control input, while the D024 versions use a low-voltage DC input.
Applications and mounting
Typical use is temperature control of electric heaters, ovens and heat-sealing tools driven from a temperature controller with AC or relay output.
Non-repetitive surge current is 520 A (t = 10 ms); the isolation between input and output is 5000 V. Observe the mounting orientation and clearances for convection cooling.
For panel design and commissioning, the practical figures to keep at hand are: operating voltage drop-out 20 V; off state leakage current 1 mA; on state output voltage drop 1.2 V; critical rate of rise of off-state voltage dv/dt 1000 V/µs; non repetitive surge peak on state current t=10ms 520 A; I2t 1350 A2s; input – Output isolation 5000 V; input – Output to metal base 5000 V; control terminals Screw Type; terminals tool Blade 3.5mm; operating position, allowable On vertical plane; fixing Screw or on 35mm DIN rail; operating temperature (min) -40 °C; operating temperature (max) +80 °C. These come straight from the datasheet and are repeated here so that the key installation limits are visible without opening the PDF.
Related Lovato Electric products: Lovato HS1B6NT060E230 60 A Solid State Relay, 18-280 V Control and Lovato DCTLA4000150 Thyristor Module.
Documents and quotation
The Lovato Electric datasheet for HS1C6HV025A230 (English, exported from the manufacturer’s online catalogue) is attached and is the source of the figures above. Before ordering, confirm the load type and current, the control signal voltage and the heatsink arrangement; datasheet values can be revised by the manufacturer. For related parts browse power modules. Send the order code HS1C6HV025A230, the quantity and the delivery location through the quotation form and Seven Star LLC, an independent supplier in Muscat, will reply with availability.
Datasheets & Documents
- Datasheet Lovato Electric HS1C6HV025A230 datasheet (EN, catalogue export) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Lovato Electric is the Italian manufacturer of low-voltage electrical components for industrial automation and power distribution: contactors, motor protection circuit breakers, soft starters, variable speed drives, power factor controllers, transfer switch and generator controllers, and energy meters. It was founded in Bergamo in 1922 and has been run by the same family for four generations. Its headquarters is in Gorle, near Bergamo, and it celebrated its centenary in 2022.
Seven Star LLC is an independent supplier in Muscat. We list Lovato motor control, drives and power management products, and supply them to panel builders, contractors and maintenance teams in Oman and the GCC by order code.
Lovato Electric at a glance
| Established | 1922, Bergamo, Italy |
|---|---|
| Headquarters | Gorle (Bergamo), Italy |
| Ownership | Private, family-run for four generations |
| Product families | Contactors and relays, motor protection circuit breakers, motor starters, soft starters, variable speed drives, power factor controllers, ATS and gen-set controllers, multimeters and energy meters, micro PLCs |
Lovato products we list
| Family | Models | Typical use |
|---|---|---|
| Contactors | BF0910A230, BF1810A230, BF2510A230, BF2600A230, BF09T4A230 4-pole, BFS0923A024, 11BG0910A230 mini, 11BGR0901A048 reversing | Switching motors, heaters, lighting and capacitor banks |
| Motor protection and starters | SM1P0650, SM1P1000, SM1P3200, M1P enclosed DOL starter, ME024FD024, ME070RSD024, 31L48 time relay | Short-circuit and overload protection and direct starting of motors |
| Soft starters | ADXL0030600, ADXL0085600, ADXL0135600, ADXT0034, ADXT0084, ADXT0139 | Reducing starting current and mechanical shock on pumps, fans and compressors |
| Variable speed drives | VLA1, VLB1, VLB3 0.75 kW, VLB3 2.2 kW, VLB3 5.5 kW, VLB3 22 kW, VT1 | Speed control of pumps, fans and conveyors to save energy |
| Power management and control | DCRG8, DCRL8 PF controllers, ATL600 ATS controller, RGK600 gen-set controller, DMG200 multimeter, DMED300T2 energy meter, LRD20 micro PLC | Power factor correction, mains/generator changeover and energy monitoring |
Lovato order codes describe the product. On a contactor such as BF0910A230, "BF09" is the frame and rated current (9 A in AC-3), "10" is the built-in auxiliary contact (one normally open), "A" means an AC coil and "230" is the coil voltage. The coil voltage must match the control circuit exactly, so it is the most common detail to check when replacing one. For motors, a soft starter limits the inrush current at start and stop, while a variable speed drive controls the speed continuously and saves energy on pumps and fans that do not need full flow all the time.
Where Lovato products are used
In Oman and the GCC, Lovato components are built into motor control centres, pump and HVAC panels, capacitor banks for power factor correction, generator and ATS panels, and machine control panels for industry, water and buildings.
Ordering Lovato products: what we need
Send the full Lovato order code. For contactors and starters, confirm the coil or control voltage. For drives and soft starters, send the motor power, current and supply voltage. For power factor controllers, send the number of steps and the CT ratio.
Facts checked against Lovato Electric company profile brochures, October 2026.
Browse Lovato Electric products by category: Motor Soft Starters, Automation Accessories, Controllers & Data Acquisition, PLC & I/O Cards, Circuit Breakers, Diesel Generator Spare Parts.
FAQ
Questions about the Lovato HS1C6HV025A230 25 A Solid State Relay with
Answers from our engineering team on installation, compatibility and integration.
01What current does the HS1C6HV025A230 switch?
25 A at 40 degC and 22 A at 55 degC (resistive, AC-51).
02What control voltage does it need?
90-280VAC.
03What load voltage does it switch?
48-600 VAC.
04Is it zero-crossing?
Switching mode: Zero crossing.
05What degree of protection does the HS1C6HV025A230 have?
IP20 (on front).


















Reviews