Lovato HS1B6NT060E230 60 A Solid State Relay, 18-280 V Control
Description
A 60 A hockey-puck solid state relay for AC loads
The HS1B6NT060E230 is a single-phase solid state relay in the hockey-puck format from the Lovato Electric HS1 series. It switches AC loads up to 60 A at 40 degC (derating to 52 A at 55 degC) at an operating voltage of 24-600 VAC, with a thyristor (SCR) output and zero-crossing switching.
The control input accepts 18-280VAC/DC, with pick-up at 18 V and drop-out at 8 V. The blocking voltage is 1200 V, non-repetitive surge current 750 A, on-state drop 1.45 V, and input-to-output isolation 4000 V.
Technical specifications
| Parameter | Specification |
|---|---|
| Order code | HS1B6NT060E230 |
| Product designation | Solid state relay |
| Product type designation | HS1B |
| Type | single-phase |
| Control voltage | 18-280VAC/DC |
| Operating voltage pick-up | 18 V |
| Operating voltage drop-out | 8 V |
| Input current at min…max voltage | 4.5-6 mA |
| Switching-on | Half cycle max |
| Switching-off | Half cycle max |
| Static output type | SCR (silicon controlled rectifier) |
| Switching mode | Zero crossing |
| Rated operating voltage | 24-600 VAC |
| Blocking voltage | 1200 V |
| Operational frequency (min…max) | 45-65 Hz |
| Rated operating current AC-51 (resistive load) at 40°C | 60 A |
| Rated operating current AC-51 (resistive load) at 55°C | 52 A |
| Thermal resistance between junction to case | 0.4 K/W |
| Heatsink for use at 40°C and 55°C at rated current AC-51 | ≤0.55 K/W |
| Operational current min | 0.05 A |
| Non repetitive surge peak on state current t=10ms | 750 A |
| Off state leakage current | 1 mA |
| On state output voltage drop | 1.45 V |
| Critical rate of rise of off-state voltage dv/dt | 500 V/µs |
| Input – Output isolation | 4000 V |
| Input – Output to metal base | 4000 V |
| I2t | 2800 A2s |
| Control terminals | Screw M4 Type |
| Terminals tool | PZ2 |
| Operating temperature (min) | -55 °C |
| Operating temperature (max) | +90 °C |
| Storage temperature (min) | -55 °C |
| Storage temperature (max) | +125 °C |
| Protection degree | IP20 |
Selecting the relay
A solid state relay needs a heatsink: the datasheet specifies a heatsink thermal resistance of ≤0.55 K/W for full rated current at 40 and 55 degC, and the junction-to-case resistance is 0.4 K/W. Without sufficient cooling the usable current drops.
In the catalogue the E230 suffix corresponds to the 18-280 V AC/DC control input and the D024 variants to a DC-only control input. Choose the version that matches your controller output (a PLC output at 24 V DC, or a 230 V AC thermostat).
Applications and mounting
Typical duty is switching resistive heaters in plastic processing, packaging and furnace control, where mechanical contactors would wear out under frequent switching. Match the load type: inductive loads and motors need derating or special SSR versions.
Mount the relay on a flat, clean heatsink with thermal compound, tighten the screw terminals to the torque in the datasheet, and protect the circuit with ultra-fast fuses where the datasheet requires.
For panel design and commissioning, the practical figures to keep at hand are: operating voltage drop-out 8 V; off state leakage current 1 mA; on state output voltage drop 1.45 V; critical rate of rise of off-state voltage dv/dt 500 V/µs; non repetitive surge peak on state current t=10ms 750 A; I2t 2800 A2s; input – Output isolation 4000 V; input – Output to metal base 4000 V; control terminals Screw M4 Type; terminals tool PZ2; operating temperature (min) -55 °C; operating temperature (max) +90 °C; storage temperature (min) -55 °C; storage temperature (max) +125 °C. These come straight from the datasheet and are repeated here so that the key installation limits are visible without opening the PDF.
Related Lovato Electric products: Lovato HS1C6HV025A230 25 A Solid State Relay with Heatsink and Lovato DCTLA4000150 Thyristor Module.
Documents and quotation
Attached is the English datasheet that Lovato Electric’s online catalogue generates for HS1B6NT060E230; the specification table above reproduces its values. What to confirm before ordering: the load type and current, the control signal voltage and the heatsink arrangement. The manufacturer can revise published data at any time. For related parts browse power modules. Send the order code HS1B6NT060E230, the quantity and the delivery location through the quotation form and Seven Star LLC, an independent supplier in Muscat, will reply with availability.
Datasheets & Documents
- Datasheet Lovato Electric HS1B6NT060E230 datasheet (EN, catalogue export) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Lovato Electric is the Italian manufacturer of low-voltage electrical components for industrial automation and power distribution: contactors, motor protection circuit breakers, soft starters, variable speed drives, power factor controllers, transfer switch and generator controllers, and energy meters. It was founded in Bergamo in 1922 and has been run by the same family for four generations. Its headquarters is in Gorle, near Bergamo, and it celebrated its centenary in 2022.
Seven Star LLC is an independent supplier in Muscat. We list Lovato motor control, drives and power management products, and supply them to panel builders, contractors and maintenance teams in Oman and the GCC by order code.
Lovato Electric at a glance
| Established | 1922, Bergamo, Italy |
|---|---|
| Headquarters | Gorle (Bergamo), Italy |
| Ownership | Private, family-run for four generations |
| Product families | Contactors and relays, motor protection circuit breakers, motor starters, soft starters, variable speed drives, power factor controllers, ATS and gen-set controllers, multimeters and energy meters, micro PLCs |
Lovato products we list
| Family | Models | Typical use |
|---|---|---|
| Contactors | BF0910A230, BF1810A230, BF2510A230, BF2600A230, BF09T4A230 4-pole, BFS0923A024, 11BG0910A230 mini, 11BGR0901A048 reversing | Switching motors, heaters, lighting and capacitor banks |
| Motor protection and starters | SM1P0650, SM1P1000, SM1P3200, M1P enclosed DOL starter, ME024FD024, ME070RSD024, 31L48 time relay | Short-circuit and overload protection and direct starting of motors |
| Soft starters | ADXL0030600, ADXL0085600, ADXL0135600, ADXT0034, ADXT0084, ADXT0139 | Reducing starting current and mechanical shock on pumps, fans and compressors |
| Variable speed drives | VLA1, VLB1, VLB3 0.75 kW, VLB3 2.2 kW, VLB3 5.5 kW, VLB3 22 kW, VT1 | Speed control of pumps, fans and conveyors to save energy |
| Power management and control | DCRG8, DCRL8 PF controllers, ATL600 ATS controller, RGK600 gen-set controller, DMG200 multimeter, DMED300T2 energy meter, LRD20 micro PLC | Power factor correction, mains/generator changeover and energy monitoring |
Lovato order codes describe the product. On a contactor such as BF0910A230, "BF09" is the frame and rated current (9 A in AC-3), "10" is the built-in auxiliary contact (one normally open), "A" means an AC coil and "230" is the coil voltage. The coil voltage must match the control circuit exactly, so it is the most common detail to check when replacing one. For motors, a soft starter limits the inrush current at start and stop, while a variable speed drive controls the speed continuously and saves energy on pumps and fans that do not need full flow all the time.
Where Lovato products are used
In Oman and the GCC, Lovato components are built into motor control centres, pump and HVAC panels, capacitor banks for power factor correction, generator and ATS panels, and machine control panels for industry, water and buildings.
Ordering Lovato products: what we need
Send the full Lovato order code. For contactors and starters, confirm the coil or control voltage. For drives and soft starters, send the motor power, current and supply voltage. For power factor controllers, send the number of steps and the CT ratio.
Facts checked against Lovato Electric company profile brochures, October 2026.
Browse Lovato Electric products by category: Motor Soft Starters, Automation Accessories, Controllers & Data Acquisition, PLC & I/O Cards, Circuit Breakers, Diesel Generator Spare Parts.
FAQ
Questions about the Lovato HS1B6NT060E230 60 A Solid State Relay,
Answers from our engineering team on installation, compatibility and integration.
01What current does the HS1B6NT060E230 switch?
60 A at 40 degC and 52 A at 55 degC (resistive, AC-51).
02What control voltage does it need?
18-280VAC/DC.
03What load voltage does it switch?
24-600 VAC.
04Is it zero-crossing?
Switching mode: Zero crossing.
05What degree of protection does the HS1B6NT060E230 have?
IP20.


















Reviews