PH1100 is the basic model of HORIBA’s LAQUA 1000 benchtop pH series: a black-and-white static-LCD meter for pH, ORP and temperature with up to five-point calibration, 0.01 pH accuracy, 500-record memory, RS-232 output and an integrated electrode stand.

A no-nonsense bench pH meter for routine laboratory checks

Where the F-72 offers a touch screen and ion measurement, the PH1100 keeps to the essentials. A custom static LCD shows pH, temperature, calibration points and an electrode status icon; the keys are capacitance switches. The manual points out that these keys cannot be operated through thick gloves, so use bare hands or thin rubber gloves.

Calibration is automatic with up to five points from USA or NIST buffer sets, and the display shows offset and slope, with separate acid and alkaline slopes depending on the calibration points used. Readings can be switched between 0.1 and 0.01 pH resolution, held automatically when stable (auto-hold or auto-stable) and temperature-corrected by ATC from an electrode sensor or by MTC from a typed value.

Features on the product page

  • Automatic pH calibration with up to five points using USA or NIST buffers; offset and slope display.
  • Switchable resolution of 0.1 or 0.01 pH; pH range -2.00 to 20.00 pH.
  • Automatic or manual temperature compensation and a temperature calibration function.
  • Built-in memory for up to 500 results; RS-232 output to a GLP/GMP-compatible printer or a computer.
  • Password security and a two-year meter warranty, as stated on the product page.

Technical specification

Performance

Parameter Specification
Model LAQUA PH1100 (manual also covers PH1000-series PH1200 and PH1300)
pH range / resolution / accuracy -2.00 to 20.00 pH / 0.1 and 0.01 pH / ±0.01 pH
Calibration points / buffers Up to 5 / USA, NIST
ORP range / resolution / accuracy ±2000 mV / 0.1 mV / ±0.2 mV
Temperature range / resolution / accuracy -30.0 to 130.0 °C / 0.1 °C / ±0.4 °C
Memory 500 records
Electrode status / diagnostics On-screen display / diagnostic messages

Instrument data

Parameter Specification
Display Custom black-and-white static LCD
Inputs / output BNC, phono and DC sockets / RS-232
Power AC adapter, 100 to 240 V, 50/60 Hz, with six plug adapters (US, EU, UK, ANZ, Korea, China)
Weight / dimensions 500 g; 170 (L) x 174 (D) x 73 (H) mm
Storage conditions 0 to 45 °C, below 80 % relative humidity, no condensation (manual)

Kits

Parameter Specification
PH1100-S Meter, protection cover, integrated electrode stand, power adapter with 6 plugs, 9615S-10D ToupH glass-body refillable pH electrode with temperature sensor, 502-S buffers pH 4.01 / 7.00 / 10.01 and 3.33 M KCl reference electrolyte (250 mL each), instruction manual
PH1100-SN Kit with 501-S NIST buffers pH 4.01 / 6.86 / 9.18 and 3.33 M KCl, available on request

PH1100 compared with the rest of the 1000 series

The manual covers three meters. The PH1100 has 0.1 and 0.01 pH resolution, USA and NIST buffers and a 500-record memory. According to the manual, the PH1200 and PH1300 add 0.001 pH resolution and custom buffers, hold up to 999 records, and the PH1300 adds ion measurement. If your tolerance is 0.01 pH and you only need pH and ORP, the PH1100 is sufficient; for ion work or finer resolution look at the PH1300, F-72 or the 2000 series.

Choose PH1100-S for USA buffers or PH1100-SN for NIST buffers. The kit electrode is refillable, so plan for the 3.33 M KCl solution that comes with the kit.

Setup, calibration and maintenance

Set the instrument on the bench, fit the electrode in the built-in stand and connect the BNC and temperature plugs. Settings are grouped in the SET menu: P1 for pH (resolution, buffer set, calibration data and alarm), P3 for temperature compensation (ATC or MTC) and P4 for general items such as auto-hold type, auto power-off, date, printing and password. Calibration needs the electrode immersed at least 3 cm in the standard; stirring helps for ion work.

Error No. 0008 appears when the calibration interval has expired and error No. 0010 when more than 500 records are stored; copy the data to a PC and delete it from memory. For care, wipe the case with a dry soft cloth or a cloth with alcohol, keep it from direct sunlight and corrosive gas, and store electrodes with the cap and a little pure water. Clean oily electrodes with alcohol or diluted neutral cleaner, and inorganic deposits with 1 mol/L HCl, as the manual lists.

Where this entry-level bench meter fits

Water-treatment laboratories, school and university teaching labs, food and beverage QC and plant laboratories need dependable pH readings, without touch-screen functions they will not use. The RS-232 output allows printed records for the file when an audit asks for them.

Selection and installation notes

Laboratory and field water analysis instruments are selected from the parameter, the range and the accuracy needed. Calibrate with fresh buffers or standards that bracket the expected readings, rinse the sensor between samples, keep the sensor wet and clean as the maker advises, record the temperature with every reading and replace sensors at the interval the manual states. Keep the calibration record with the results.

Information needed for a quotation

Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.

Documents and supply information

The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.

Related items

The F-72 (pH and ion) and DS-72 (conductivity) use a different housing with touch screens. Electrodes, buffers and printers are available on request.

Documents and quotation

For quotation, send your required quantity and destination. The Horiba instruction manual for PH1100 is provided below the description on this page. Seven Star LLC works as an independent supplier from Muscat. Please compare code, ratings and approvals with the document before you place an order; see also the category listing.

Datasheets & Documents
  • PDF Manual Horiba LAQUA PH1100/PH1200/PH1300 instruction manual (PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HORIBA is a Japanese maker of analytical and measurement instruments, headquartered in Kyoto. Its origins go back to 1945, when Masao Horiba, then a Kyoto University student, set up the Horiba Radio Laboratory; the company was incorporated as Horiba, Ltd. in 1953 and began mass-producing pH meters in the early 1950s. In 1964 it built its first automotive emission analyser, the MEXA-1.

Seven Star LLC is an independent supplier in Muscat. We list Horiba LAQUA meters with the official manual beside each listing, for water, laboratory and environmental users in Oman and the GCC.

Horiba company profile

Origins 1945, Kyoto, Horiba Radio Laboratory
Founder Masao Horiba
Incorporated Horiba, Ltd., 1953
Headquarters Kyoto, Japan
Product families LAQUA handheld pH, ORP, conductivity, dissolved oxygen and turbidity meters, LAQUAtwin pocket meters, multi-parameter water quality meters, process water analysers, emission and gas analysers

Milestones

  • 1945: Masao Horiba sets up his laboratory in Kyoto.
  • 1953: Horiba, Ltd. is incorporated.
  • 1964: HORIBA builds the MEXA-1 emission analyser.

Horiba product series

LAQUAtwin pocket meters include the pH-33 pH meter, the 4EC-33 conductivity and TDS meter and the Salt-22 salinity meter, which read from a few drops of sample. Handheld meters include the LAQUA PH220 pH and ORP meter, the DO220 galvanic dissolved oxygen meter, the TB220-K turbidity kit to ISO 7027 and the WQ-330-K three-channel water quality meter.

Benchtop meters include the PH1100 pH and ORP meter, the DS-72 conductivity, TDS and salinity meter and the F-72 touch screen pH, ORP and ion meter.

Where Horiba meters are used

Water and wastewater treatment, desalination and cooling water checks, quality control laboratories, food and agriculture, aquaculture and environmental field surveys.

Horiba products we list

Family Examples
Portable Test & Measurement LAQUA DO220 Handheld Dissolved Oxygen Me…, LAQUA PH220 Handheld pH/ORP/Temperature…, LAQUA TB220-K Portable Turbidity Meter Kit, LAQUA WQ-330-K 3-Channel Handheld Water…, LAQUAtwin 4EC-33 Pocket Conductivity and…, LAQUAtwin Salt-22 Pocket Salinity Meter

Ordering Horiba meters: what we need

Send the model, the parameters and ranges needed, whether a kit with electrodes and standards is required, and any data logging or PC output needs.

Facts checked against HORIBA's published company history and HORIBA Report, October 2026.

FAQ

Questions about the Horiba LAQUA PH1100 Benchtop pH/ORP/Temperature

Answers from our engineering team on installation, compatibility and integration.

01What is the pH accuracy of the PH1100?
±0.01 pH, with 0.1 and 0.01 pH resolution selectable.
02How many calibration points does it support?
Up to five points using USA or NIST buffers.
03How many results can be stored?
The manual gives a maximum of 500 items for the LAQUA-PH1100.
04What power supply does it need?
An AC adapter for 100 to 240 V, 50/60 Hz, supplied with six plug adapters.
05Does Seven Star LLC act as a Horiba distributor?
No. Seven Star LLC is an independent supplier in Muscat that sources Horiba products on request.