Brand:

Honeywell TR23-H/U Wall Module Temperature and Humidity

Description

What sets TR23-H/U apart

Honeywell TR23-H/U adds a humidity element to the TR23 formula. In the family table it is the only wall module in the TR23 range marked for both temperature and humidity sensing together with setpoint adjustment, an override button with LED and a LON jack. That makes one wall plate carry three controller connections: room temperature, relative humidity and occupant demand.

Facts come from Honeywell form 63-1321E. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Humidity output and DIP switches

The humidity output accuracy is plus or minus 5 percent from 20 to 80 percent RH. A two-position DIP switch, S1, sets the humidity sensing control mode to match the controller: both switches off gives 0 to 10 Vdc, switch 1 off and 2 on gives 0 to 5 Vdc, and switch 1 on and 2 off gives 4 to 20 mA. These settings apply to the TR21-H and TR23-H models. Change them with power off. Other DIP switches S2 and S3 are set according to the installation instructions, form 62-0267, and the circuit-board drawing in the datasheet marks a factory humidity potentiometer next to the terminal block.

TR23-H/U reference table

Parameter Value
Model TR23-H/U
Functions Temperature, humidity, setpoint, override with LED, LON jack
Humidity output accuracy Plus or minus 5 percent, 20 to 80 percent RH
Humidity output modes 0 to 10 Vdc, 0 to 5 Vdc, 4 to 20 mA (DIP switch S1)
Sensor element 20K ohm non-linear NTC; accuracy better than plus or minus 0.36 F (0.2 C) across 55 to 85 F (13 to 29 C)
Operating range 45 to 99 F (7 to 37 C); shipping minus 40 to 150 F
Humidity 5 to 95 percent RH non-condensing
Construction Two-piece: cover plus internally wired subbase
Field wiring 16 to 22 AWG (1.31 to 0.33 sq mm) to terminal block
Mounting Standard 2 x 4 in junction box or 60 mm round box
Approvals CE; UL94 plastic enclosure; FCC Part 15 Class B
Replaces T7560B1016, T7560B1024 (as listed by the manufacturer)

How TR23-H/U differs from other TR20-family wall modules

The plain TR23-H/U differs from TR23/U by the humidity element; from TR21-H/U by having the dial and override button; from TR23-F3/U by having humidity instead of a fan switch. The terminal table also lists an 18 to 24 Vac supply coming from the controller to power the humidity sensor.

Terminal use with different controllers

The datasheet’s terminal table maps the H model to W7750, W7751, W7752 and W7753 Excel 10 units, Spyder PUL and PVL, and to Excel 600, 500, 100 and 80 with or without fan. Because this model needs a humidity input, confirm the controller has a free input of the matching type before purchase.

Application ideas

A practical benefit of the H version is that it removes a separate humidity transmitter from the wall: one box on the wall replaces a thermostat plus a stand-alone sensor, which cuts the number of cable pulls and wall penetrations in a refurbishment. Humidity control matters in Gulf coastal sites, where outdoor air carries a lot of moisture. Use the module in laboratories, archives, hospitals, hotel guest rooms and control rooms where dehumidification by reheat or by an extended coil is part of the sequence.

Installation steps

Allow for the installation guidance that the wall module wiring can be sized from 16 to 22 AWG and that one segment of cable should not mix wire types. Pick the DIP position first, then fix the subbase to a 2 x 4 in or 60 mm box, land 16 to 22 AWG conductors, and snap the cover on. Keep wiring a foot from motors, ballasts and large panels; use shielded cable and ground the shield at the controller case only if that spacing cannot be kept. For TR23-H/U also run a separate pair for the LONMARK jack if you use it, remembering that the bus wire is polarity insensitive and should be Level IV 22 AWG, and that the jack plug has to be removed in the field before wiring terminals 3 and 4. Record the position of S1, S2 and S3 on the commissioning sheet.

Selecting a humidity-capable wall module

Two models carry a humidity element: TR21-H/U and TR23-H/U. The first has no dial or override and is purely a sensing point; the second has everything. Pick TR23-H/U when occupants need setpoint and bypass in a space where humidity also drives the sequence. The datasheet table lists the TR21-H/U as replacing T7560C1006 and H7012B1024, and this model as replacing T7560B1016 and T7560B1024, which helps when you are matching old part numbers on a retrofit schedule.

Mechanical set-up is straightforward. After setting S1, the installer sets S2 and S3 as shown in installation instructions 62-0267 for the particular controller, mounts the subbase on a 2 x 4 in or 60 mm box, lands the conductors and closes the cover, which is held by a single locking mechanism. Remember that the three humidity signal types are not interchangeable between controllers. A controller input that expects 4 to 20 mA will read nonsense from a module still set to 0 to 10 Vdc, so verify S1 with the power removed and document the setting on the as-built drawings. Where more than one humidity wall module is used on a project, label the final switch settings on the back of the subbase.

Environmental ratings are the family values: operating range 45 to 99 F (7 to 37 C), shipping range minus 40 to 150 F (minus 40 to 65.5 C), 5 to 95 percent RH non-condensing. In coastal Oman sites where condensation can occur near supply grilles, place the module on an interior wall away from the air stream.

Documents and quotation

Use the Honeywell TR21, TR22 and TR23 specification data as the datasheet for TR23-H/U. Please send the part number TR23-H/U, quantity and delivery point with your RFQ.

Other Models in the TR20 Wall Modules Range

Seven Star LLC supplies models from the TR20 Wall Modules range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Honeywell TR21/U Wall Module Room Temperature SensorRTD & Thermocouple SensorsView details
Honeywell TR23/U Wall Module Setpoint and OverrideRTD & Thermocouple SensorsView details
Honeywell TR23-H/U Wall Module Temperature and HumidityHumidity & Dew Point InstrumentsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Honeywell TR23-H/U Wall Module Temperature and Humidity Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell TR23-H/U Wall Module Temperature and

Answers from our engineering team on installation, compatibility and integration.

01Does the Honeywell TR23-H/U measure humidity?
Yes. It combines a temperature sensor with a humidity element, with output accuracy of plus or minus 5 percent from 20 to 80 percent RH.
02How is the humidity signal type set on TR23-H/U?
By DIP switch S1: 0 to 10 Vdc, 0 to 5 Vdc or 4 to 20 mA, set with the power disconnected.
03Does TR23-H/U have a dial and override button?
Yes. It lists selectable setpoint adjustment, an override button with LED and a LON jack.
04Which models are replaced by TR23-H/U?
Honeywell lists T7560B1016 and T7560B1024 as the existing models replaced.
05What temperature range does TR23-H/U sense?
It senses 45 to 99 F (7 to 37 C) with better than 0.36 F accuracy across 55 to 85 F.