Michell EPR-IS Easidew PRO I.S. Intrinsically Safe Transmitter

Description

Michell EPR-IS overview: intrinsically safe dew-point transmitter

Michell EPR-IS is the parent order code of the Michell Easidew PRO I.S., a two-wire intrinsically safe dew-point transmitter for trace moisture in gas. It is supplied with a sintered guard and is built for natural gas, petrochemical and refinery applications.

The datasheet gives a measurement range of minus 110 to plus 20 degrees Celsius dew point, an accuracy of plus or minus 1 degree Celsius dew point from plus 20 to minus 60 degrees, a 525 barg pressure rating and a traceable 13-point calibration certificate. Certification listed includes ATEX, UKCA, IECEx and cQPSus for intrinsic safety.

Plants that already run intrinsically safe loops with barriers or galvanic isolators choose Michell EPR-IS because it fits that architecture without a flameproof enclosure.

The image shows the Easidew PRO I.S. transmitter from the manufacturer datasheet, the product that the EPR-IS code orders.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list EPR-IS so that maintenance, instrumentation and procurement teams can quote the exact code that appears in the manufacturer documentation.

Key features of EPR-IS

  • Intrinsically safe two-wire 4-20 mA transmitter: ATEX and UKCA II 1 G Ex ia IIC T4 Ga, IECEx Ex ia IIC T4 Ga, cQPSus Class I Division 1 Groups A to D.
  • Range of minus 100 or minus 110 to plus 20 degrees Celsius dew point, with non-standard ppmV, mg per cubic metre and natural gas units available at order.
  • Pressure rating of 52.5 MPa (525 barg, 7614 psig) with a 5/8 inch 18 UNF process connection and bonded seal; G1/2 and 3/4 inch UNF adaptors available.
  • 316 stainless steel housing, IP66 and NEMA 4, weight 1.27 kg, screw terminals through an M20 gland.
  • Optional cleaning for enriched oxygen service and material certificates to BS EN 10204 3.1.
  • Factory-programmed diagnostics: 23 mA sensor fault, 4 mA under range, 20 mA over range.

EPR-IS technical specifications

The table below lists values published by the manufacturer for the product family of EPR-IS. Where a value depends on the ordered configuration, the table says so and the order-code sheet governs.

Parameter Value
Order code (parent) EPR-IS, 2-wire dew-point transmitter, ATEX certified, with sintered guard
Measurement range Minus 110 to plus 20 degC dp or minus 100 to plus 20 degC dp
Accuracy Plus or minus 1 degC dp (plus 20 to minus 60 degC); plus or minus 2 degC dp (minus 60 to minus 110 degC)
Response time 5 minutes to T95 (dry to wet)
Repeatability 0.5 degC dew point
Calibration Traceable 13-point certificate
Output 4-20 mA, two-wire
Supply voltage 12 to 28 V DC
Load resistance Maximum 250 ohm at 12 V; 500 ohm at 24 V
Operating temperature Minus 40 to plus 60 degC; compensated minus 20 to plus 50 degC
Operating pressure 52.5 MPa (525 barg) maximum
Ingress protection IP66; NEMA 4
Intrinsic safety ATEX/UKCA II 1 G Ex ia IIC T4 Ga; IECEx Ex ia IIC T4 Ga; Tamb minus 20 to plus 70 degC
Housing 316 stainless steel
Process connection 316 stainless steel 5/8 inch 18 UNF with bonded seal
Weight 1.27 kg
Approved galvanic isolators (datasheet) KFD0-CS-EX2.50P, KFD0-CS-EX1.50P, KFD2-STC4-EX1.H, MTL5541

Typical applications of EPR-IS in Oman and the GCC

  • Natural gas production and processing and pipeline drying.
  • Fiscal metering of gas and LNG production, receiving terminals.
  • Catalyst protection and polymer production.
  • CNG drying and metallurgical furnace blanket gas.
  • Compressed air in hazardous areas.

In Oman and across the GCC, moisture measurement matters wherever gas has to stay dry: gas gathering and processing plants, LNG and gas-to-power facilities, refineries and petrochemical complexes, desalination and utility compressed-air systems, and industrial gas and hydrogen users. High ambient temperatures and humidity make dryer performance and sensor drift a real operating cost, so a transmitter such as EPR-IS is usually specified against a defined dew-point or ppmV target and a documented calibration.

Selection and compatibility notes

The EPR-IS order string selects the range letter (A for minus 100 to plus 20, B for minus 110 to plus 20) and an oxygen cleaning letter, with a non-standard range option for ppmV or natural gas units, where the operating pressure is required for conversion.

The datasheet states that an intrinsically safe installation needs a certified barrier or isolator and that the end user is responsible for compliance with installation standards. Compare the entity parameters with your loop design before ordering.

Confirm four things before ordering EPR-IS: the dew-point or ppmV range you need, the process connection and sample handling arrangement, the hazardous-area certification that your site requires, and the electrical interface of your control system. Because Michell builds many variants from one parent code, quote the complete configured code from the order-code sheet where one applies, and tell us the operating pressure so that ppmV conversions are programmed correctly.

Installation and commissioning of EPR-IS

Mount the transmitter in a sample block or directly in the line within the stated pressure rating, using the process adaptors listed on the order-code sheet, such as APT-PAN, APT-GEI and APT-TSO, if the plant thread differs from 5/8 inch UNF.

Use cable entry adaptors and glands listed for the certificate, such as the M20 entries on the manufacturer list.

Mount the sensor in a sampling arrangement that delivers a clean, representative gas stream at a controlled flow, keep sample lines short and use stainless steel or other low-adsorption tubing, and avoid dead legs, because trace moisture adsorbs on tubing walls and slows the response. Wire the 4-20 mA loop with screened cable, check loop supply and load against the datasheet limits, and allow the sensor to stabilise on dry gas before judging the first readings. Record the as-found reading and the calibration certificate number at commissioning.

Maintenance, calibration and service

The manufacturer lists a service exchange under EPR-IS-X and a recalibration service EPR-IS-RECAL. Spare codes on the sheet include SSG sintered guard, EPR-SC internal sensor connector, EPR-14127 lid O-ring and EPR-BRK wall bracket.

Ceramic moisture sensors are stable, but periodic verification keeps a dryer control loop honest. Plan recalibration or sensor exchange at the interval set by your quality system, inspect the sensor guard and seals at each visit, and replace guards that are clogged by particulates or contaminated by oil mist. If a reading drifts, check the sample system for leaks and condensate before suspecting the sensor.

Related products and ordering notes for EPR-IS

  • EPR-LQ-IS: moisture-in-liquids version of the same family.
  • EA-XP: flameproof Easidew PRO XP for gases.
  • EA2-IS-TX: Easidew I.S. intrinsically safe transmitter in the smaller body.

When you request EPR-IS, tell us whether the item is for a new installation, a like-for-like replacement or a spares stock, because that changes which accessories and documents are worth adding to the same quotation. Our team can also check related codes from the same order-code sheet so that one RFQ covers the transmitter or analyzer, its consumables and its calibration needs.

Frequently asked questions about EPR-IS

  • What is EPR-IS? EPR-IS is the manufacturer parent code for the Easidew PRO I.S. two-wire intrinsically safe dew-point transmitter with sintered guard.
  • What does EPR-IS suit? It suits trace moisture measurement in gas in hazardous areas that use intrinsically safe loops, for example natural gas, LNG, petrochemical and refinery services.
  • Does EPR-IS need a barrier? It is an intrinsically safe device, so it should be connected through a certified barrier or galvanic isolator; the datasheet lists approved isolators, and the loop must be checked against the certificate.
  • What should I send with an RFQ for EPR-IS? Send the part number EPR-IS, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.

Documents and quotation

A manufacturer document is available for the product family of EPR-IS and we can send it with your quotation where the family datasheet applies. To request pricing and lead time, send an RFQ to Seven Star LLC with the part number EPR-IS, the quantity, the full configuration or host-instrument details, the delivery location and any certificate requirements such as material certificates or calibration documents. We will confirm availability and respond with a quotation for EPR-IS in writing.

Other Models in the Michell Easidew Pro Is Range

Seven Star LLC supplies models from the Michell Easidew Pro Is range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Michell EPR-IS Easidew PRO I.S. Intrinsically Safe TransmitterHumidity & Dew Point InstrumentsYou are viewing this model
Michell EPR-LQ-IS Easidew PRO LQ I.S. Moisture-in-Liquids TransmitterHumidity & Dew Point InstrumentsView details
Datasheets & Documents
  • PDF Datasheet Michell EPR-IS Easidew PRO I.S. Intrinsically Safe Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).

Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.

MICHELL Instruments company profile

Founded 1974, Cambridge, England, by Andrew Michell
Headquarters Ely, Cambridgeshire, United Kingdom, since 2007
Ownership Process Sensing Technologies (PST)
Technology Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell)
Product families Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers

Milestones

  • 1974: Andrew Michell founds Michell Instruments in Cambridge.
  • 2007: The company moves to Ely, Cambridgeshire.
  • 2024: Michell marks 50 years, now as part of PST.

Michell product families on this page

The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.

Where Michell analyzers are used

Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.

MICHELL Instruments products we list

Family Examples
Gas Analyzer Systems Easidew PRO I.S. Intrinsically Safe Mois…, Michell CD2-WDC-002 Water Dew-Point Sens…, Michell Condumax II Hydrocarbon Dew-Poin…, Easidew EA2 Dew Point Transmitter, Michell OptiPEAK TDL600 Moisture in Natu…, Michell Promet EExd Process Moisture Ana…, Michell S8000 Precision Chilled Mirror H…
Gas Analyzer Accessories MICHELL CD2-SX-WDC-002 Water Dew-Point S…, Michell Ceramic Impedance Moisture Senso…, Michell Condumax II CD2-SCR-002 Hydrocar…

Ordering Michell parts: what we need

For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.

Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.

FAQ

Questions about the Michell EPR-IS Easidew PRO I.S. Intrinsically Safe

Answers from our engineering team on installation, compatibility and integration.

01What is EPR-IS?
EPR-IS is the manufacturer parent code for the Easidew PRO I.S. two-wire intrinsically safe dew-point transmitter with sintered guard.
02What does EPR-IS suit?
It suits trace moisture measurement in gas in hazardous areas that use intrinsically safe loops, for example natural gas, LNG, petrochemical and refinery services.
03Does EPR-IS need a barrier?
It is an intrinsically safe device, so it should be connected through a certified barrier or galvanic isolator; the datasheet lists approved isolators, and the loop must be checked against the certificate.
04Can Seven Star LLC supply EPR-IS in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for EPR-IS?
Send the part number EPR-IS, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.