Moore Industries HSM/PT-RH/HDM/HDM/-CL12 -VTB [LH3Z] Sensor

Description

Moore Industries HSM/PT-RH/HDM/HDM/-CL12 -VTB [LH3Z]: the sensing half of the HTZ

Moore Industries HSM/PT-RH/HDM/HDM/-CL12 -VTB [LH3Z] is the humidity and temperature sensor module of the HTZ, a Smart HART transmitter that measures relative humidity and temperature at the same time and calculates dew point as a third variable. The HTZ is built from two parts, the HSM sensor module and the HDM display module, linked by a cable of 1 to 30 m. This order string describes the sensor module with its platinum RTD and humidity probes.

The code deserves reading in pieces: PT-RH is the input pair, HDM HDM in the output and power fields refers to the display module, -CL12 sets the probe length to 12 inches, -VTB requests the temperature matching calibration, and LH3Z names the enclosure of the sensor module.

Main points of HSM/PT-RH/HDM/HDM/-CL12 -VTB [LH3Z]

  • Simultaneous relative humidity, temperature and calculated dew point from one sensing assembly.
  • Probes and the RH sensor itself can be removed quickly for cleaning or replacement.
  • Temperature sensing from -40 to +110 C with 0.1 C nominal accuracy, improved to 0.036 C at trim points with the -VTB calibration.
  • Humidity sensor limits of -40 to +110 C and 125 psia, useful in warm and slightly pressurised air spaces.
  • Dew point from -45 to +100 C calculated from the two measured values.

The sensor module has no 4-20 mA of its own: the signal conditioning and outputs live in the HDM.

Technical data for HSM/PT-RH/HDM/HDM/-CL12 -VTB [LH3Z]

The values below come from the HTZ datasheet.

Parameter Value for HSM/PT-RH/HDM/HDM/-CL12 -VTB [LH3Z]
Model code HSM/PT-RH/HDM/HDM/-CL12 -VTB [LH3Z]
Unit HSM humidity and temperature sensor module of the HTZ Smart HART humidity and temperature transmitter
Sensing PT-RH: platinum RTD temperature probe plus relative humidity probe
Probe length -CL12: 12-inch sensor and probe length
Calibration option -VTB: temperature sensor-to-transmitter matching calibration
Housing LH3Z: enclosure for the sensor module (LH3 family) in this order code
Humidity range 0 to 100% RH, minimum span 10% RH
Humidity accuracy Plus or minus 1.8% nominal between 20 and 80% RH; plus or minus 0.75% RH at 33-75% with -VTRH calibration
Temperature range -40 to +110 C, minimum span 10 C
Temperature accuracy Plus or minus 0.1 C nominal; plus or minus 0.036 C at trim points with -VTB
Dew point -45 to +100 C, calculated; typical accuracy plus or minus 0.5 C between 40 and 95% RH
Sensor limits Humidity sensor temperature -40 to +110 C; maximum pressure 125 psia
Response time 10 seconds to 90% for humidity and dew point; 200 ms for the temperature input
Weight 601 g (21.2 oz) for the HSM
Remote display The HDM display can be mounted up to 30 m (98 ft) from the HSM
Storage Recommended 10-50 C and 20-60% RH; maximum 0-80 C, 0-95% RH

Use the table as a checklist for probe selection. The humidity sensor is rated for -40 to +110 C and 125 psia, while the recommended storage window is much narrower, 10-50 C and 20-60% RH, so spare modules should be kept in a conditioned store rather than in an outdoor container where the humidity element might be exposed to extremes before use.

How HSM/PT-RH/HDM/HDM/-CL12 -VTB [LH3Z] differs from the HDM display module code

The HDM/HSM/2X4-20MA/12-42DC/-3M [D3LCP] order is the other half of the HTZ: it carries the dual 4-20 mA outputs and the display, while this HSM code carries the probes. Without the HDM, the sensor module cannot generate an output, and the reverse is also true.

The -CL12 probe length can be replaced with CL3.75 or 1NPT-CL6, 1NPT-CL12 or 1NPT-CL18 per the datasheet, and a FLEX120 flexible extended sensor option exists to reach places where the connection head cannot be placed, such as suspended ceilings or mid-room positions.

Applications

The HTZ addresses industrial, commercial, manufacturing and HVAC measurements: cleanrooms, switchgear rooms where condensation risk must be tracked, paint booths, warehouses with moisture-sensitive stock, and control rooms in humid coastal sites like those in Oman.

Dew point is helpful for compressed air and instrument-air dryer monitoring, and for judging whether a cooled surface may collect condensation.

Selection notes for HSM/PT-RH/HDM/HDM/-CL12 -VTB [LH3Z]

Decide the probe length from the mounting situation: shorter probes in ducts or walls, longer ones in open air space away from the enclosure. Use -VTB if you want the temperature input matched to the transmitter, and consider -VTRH when humidity accuracy of 0.75% RH in the middle of the range matters.

Check the cable choice on the display side because only one cable length from 1 m to 30 m is selected there.

If the sensor is to sit in a duct or plenum, ask whether the 1NPT-CL6, 1NPT-CL12 or 1NPT-CL18 forms listed in the datasheet fit the entry better than the CL12 code here; these threaded versions allow a sealed pass-through at a wall or pipe.

Mounting and wiring

Mount the sensor enclosure where airflow is representative, avoiding direct sunlight, heat sources and spots with stagnant air. Connect the HSM to the HDM with the chosen cable and configure with a HART communicator or the Moore Intelligent PC Configuration Software.

Set the failure mode of each output so that a disconnected cable drives the output upscale, downscale or to hold the last value.

Maintenance

The humidity probe and temperature probe can be cleaned or replaced without replacing the module; replacement part numbers are listed in the datasheet, as is a replacement SHT75 humidity sensor. Long-term stability of the humidity channel is quoted as plus or minus 1% RH per year.

Plan periodic checks against a reference hygrometer in line with your quality plan.

Supply of HSM/PT-RH/HDM/HDM/-CL12 -VTB [LH3Z]

Quote HSM/PT-RH/HDM/HDM/-CL12 -VTB [LH3Z] in full with your requirements for probe length and calibration options.

Seven Star LLC is an independent supplier serving Oman and the wider GCC and is not affiliated with the manufacturer; all names and part numbers are used only to identify the product being requested.

Documents and quotation

The datasheet for Moore Industries HSM/PT-RH/HDM/HDM/-CL12 -VTB [LH3Z] can be attached to our quotation. Please send an RFQ with the part number, quantity and delivery location.

Datasheets & Documents
  • PDF Datasheet Moore Industries HSM/PT-RH/HDM/HDM/-CL12 -VTB [LH3Z] Sensor Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.

Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.

Moore Industries company profile

Founded 1968, North Hills, California, USA, by Leonard W. Moore
Headquarters North Hills, California, since 1974
Ownership Privately owned (Moore Industries-International, Inc.)
First product SCT signal converter
Product families Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA)

Milestones

  • 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
  • 1974: The company moves into its North Hills headquarters.
  • 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.

Moore Industries product families on this page

The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:

  • Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
  • Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
  • Signal isolators, repeaters and converters: the SIX
  • PID controllers and backup stations: the 535 in 1/4 DIN format

Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.

Where Moore Industries instruments are used

These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.

Moore Industries products we list

Family Examples
Controllers & Data Acquisition Moore 535-21120BD000 | Industrial PID Ba…, SPA2 Programmable Limit Alarm Trip, Moore-SPA2HL Associated IS Programmable…
Isolator & Barrier HIM Smart HART Loop Interface and Monitor, SIX Signal Isolator, SLA SIL 2/3 Safety Logic Solver and Alarm
Temperature Instrumentation STZ Functional Safety Dual Input Smart H…, TRX Temperature Transmitter
Industrial Communications HES HART to Ethernet Gateway
Valve Positioners IPT2 Current-to-Pressure I/P Transmitter

Ordering Moore Industries instruments: what we need

Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.

Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.

FAQ

Questions about the Moore Industries HSM/PT-RH/HDM/HDM/-CL12 -VTB

Answers from our engineering team on installation, compatibility and integration.

01What does the HSM do in the HTZ?
It is the humidity and temperature sensor module that holds the RTD and RH probes; the HDM display module provides outputs and the display.
02What does -CL12 mean?
A 12-inch sensor and humidity probe length.
03What does -VTB add?
A temperature sensor-to-transmitter matching calibration that improves temperature accuracy to plus or minus 0.036 C at trim points.
04How far can the display be from the sensor?
Up to 30 m (98 ft) using the longest connection cable.
05Which variables are measured?
Relative humidity and temperature, with dew point calculated from them.