- Automation & ControlView all 3,044 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Moore Industries
Moore Industries HDM/HSM/2X4-20MA/12-42DC/-3M [D3LCP] Display
Description
Moore Industries HDM/HSM/2X4-20MA/12-42DC/-3M [D3LCP]: display and output half of the HTZ
Moore Industries HDM/HSM/2X4-20MA/12-42DC/-3M [D3LCP] is the HDM humidity and temperature display module of the HTZ Smart HART transmitter. It receives the measured values from an HSM sensor module over a 3 m cable (the -3M option), shows them on a 2 x 5 character display, and drives two isolated 4-20 mA outputs. One HDM is required per installation, and it sits in a D3LCP NEMA 4X, IP66 enclosure supplied with 2-inch pipe-mount hardware.
The two outputs are user selectable: each can follow relative humidity, temperature or the calculated dew point. HART communication rides on output 1, which makes the module easy to integrate into a DCS or PLC that already supports HART.
What HDM/HSM/2X4-20MA/12-42DC/-3M [D3LCP] offers
- Dual analog outputs, so one device can deliver two process variables to the control system.
- A readable alphanumeric display that shows humidity, temperature, dew point, output 1, output 2 or scrolls through them at four-second intervals.
- Programmable failure behaviour for each output: drive upscale, downscale or hold the last value if a sensor fails or the cable is disconnected.
- Remote placement: the HDM can sit up to 30 m from the sensor module, so the display can be at eye level in a control area.
- Setup with a HART communicator, a HART-based system or a PC on the 4-20 mA wires of output 1.
The module is loop-powered, with the supply of 12-42 V DC taken at the output terminals.
HDM/HSM/2X4-20MA/12-42DC/-3M [D3LCP] specification table
These values come from the HTZ datasheet.
| Parameter | Value for HDM/HSM/2X4-20MA/12-42DC/-3M [D3LCP] |
|---|---|
| Model code | HDM/HSM/2X4-20MA/12-42DC/-3M [D3LCP] |
| Unit | HDM humidity and temperature display module of the HTZ |
| Input | HSM sensor module |
| Outputs | Two isolated, scalable 4-20 mA outputs, each user-selectable for relative humidity, temperature or dew point; HART on output 1 |
| Supply | 12-42 V DC at the output terminals |
| Cable option | -3M: 3 m (10 ft) cable between HDM and HSM; options 1, 3, 6, 9, 15, 25 and 30 m |
| Housing | D3LCP: surface or pipe-mount enclosure, NEMA 4X, IP66, with 2-inch pipe-mount hardware |
| Isolation | 500 Vac between each output and between outputs and case |
| Output accuracy | Plus or minus 2 microamps |
| Linear region | 3.8 to 21.4 mA; hardware limits 3.6 to 23.6 mA |
| Display | LCD 2 x 5 14-segment characters; range -99999 to 99999 |
| Load capability | 500 ohms at 24 V; (supply voltage minus 12 V) divided by 0.024 A |
| Weight | HDM 918 g (32.4 oz); cable 3 m 196 g |
| Start-up time | Less than 5 seconds |
| Analog output response | 500 ms to 90% of final value |
| Ambient | -40 to +85 C, 0 to 95% RH non-condensing |
Notice how the table lists the analog output accuracy as a small absolute current, 2 microamps, and then separately gives a 0.009% of span per degree C ambient effect and long-term stability figures of 0.012% after one year, 0.020% after three years and 0.026% after five years. Added together, these set the loop error that you should compare with the tolerance of your process.
How HDM/HSM/2X4-20MA/12-42DC/-3M [D3LCP] differs from the HSM sensor code
The HSM/PT-RH/HDM/HDM/-CL12 -VTB [LH3Z] order holds probes; this HDM order holds the electronics, the display and the outputs. An HTZ installation needs both: the HSM measures, the HDM computes dew point, scales and outputs. A replacement HDM electronics module in a hockey-puck housing is a separate option without cable selection.
The cable choice also separates the two: the HSM-HDM cable length (1, 3, 6, 9, 15, 25 or 30 m) is declared in this order, here as -3M, and weights range from 82 g for 1 m up to 1100 g for 25 and 30 m cables.
Applications
Use it for HVAC supervision, cleanroom and laboratory conditions, store rooms for electronic and pharmaceutical products, and instrument air monitoring. In the humid coastal climate of the Gulf it is helpful in control rooms and switchgear rooms, where trends of dew point warn of condensation.
Factories can also use the two outputs to feed a PLC for dehumidifier control and a data logger for quality records.
Selection
Pick the cable length that reaches from the sensing point to the display location with some slack, since only one cable option may be selected. Decide which two variables you want on outputs 1 and 2; they can be changed later with HART or PC software.
Use the -1ST or -2ST stainless steel tag options if tagging is required by your plant standard.
Installation
Mount the D3LCP on a surface or a 2-inch pipe, connect the HSM cable, connect the 12-42 V DC loop supply and the two output loops, and power up. Configure the sensor ranges, output assignments, damping (0 to 30 s) and failure modes.
The HART address and tag can be entered during the same session.
Maintenance
Check the enclosure seals, the cable and the display. Keep records of any trim adjustments performed with the configuration software, and calibrate the humidity channel against a reference environment at the interval your quality system defines.
Replacement connection cables are listed by length in the datasheet.
At commissioning, check that both output loops read plausible values with the process at rest, and that the humidity and temperature shown on the display match a portable reference. Where the dew point is used for protection, record the calculation method: the datasheet gives the equation based on saturation vapour pressure, so the logic can be reviewed by quality staff.
Supply of HDM/HSM/2X4-20MA/12-42DC/-3M [D3LCP]
Please quote HDM/HSM/2X4-20MA/12-42DC/-3M [D3LCP] in full in your enquiry and say which cable length is required.
Seven Star LLC is an independent supplier serving Oman and the wider GCC and is not affiliated with the manufacturer; all names and part numbers are used only to identify the product being requested.
Documents and quotation
The datasheet for Moore Industries HDM/HSM/2X4-20MA/12-42DC/-3M [D3LCP] can accompany our quotation. Submit an RFQ with part number, quantity and delivery location.
Other Models in the HTZ Range
Seven Star LLC supplies models from the HTZ range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Moore Industries HSM/PT-RH/HDM/HDM/-CL12 -VTB [LH3Z] Sensor | Humidity & Dew Point Instruments | View details |
| Moore Industries HDM/HSM/2X4-20MA/12-42DC/-3M [D3LCP] Display | Humidity & Dew Point Instruments | You are viewing this model |
Datasheets & Documents
- Datasheet Moore Industries HDM/HSM/2X4-20MA/12-42DC/-3M [D3LCP] Display Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.
Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.
Moore Industries company profile
| Founded | 1968, North Hills, California, USA, by Leonard W. Moore |
|---|---|
| Headquarters | North Hills, California, since 1974 |
| Ownership | Privately owned (Moore Industries-International, Inc.) |
| First product | SCT signal converter |
| Product families | Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA) |
Milestones
- 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
- 1974: The company moves into its North Hills headquarters.
- 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.
Moore Industries product families on this page
The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:
- Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
- Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
- Signal isolators, repeaters and converters: the SIX
- PID controllers and backup stations: the 535 in 1/4 DIN format
Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.
Where Moore Industries instruments are used
These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.
Moore Industries products we list
Ordering Moore Industries instruments: what we need
Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.
Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.
Browse Moore Industries products by category: Temperature Instrumentation, Controllers & Data Acquisition, Isolator & Barrier.
FAQ
Questions about the Moore Industries HDM/HSM/2X4-20MA/12-42DC/-3M
Answers from our engineering team on installation, compatibility and integration.
01How many outputs does the HDM have?
Two isolated, scalable 4-20 mA outputs, each assigned to humidity, temperature or dew point.
02What cable lengths are available?
1, 3, 6, 9, 15, 25 and 30 m; the -3M option in this code selects 3 m (10 ft).
03What enclosure does D3LCP describe?
A NEMA 4X, IP66 surface or pipe-mount enclosure supplied with 2-inch pipe-mount hardware.
04Which output carries HART?
HART communication is available on analog output 1.
05What does the display show?
Relative humidity, temperature, dew point, output 1 or output 2, or it scrolls between all variables every four seconds.

















![Moore Industries HDM/HSM/2X4-20MA/12-42DC/-3M [D3LCP] Display Moore Industries HDM/HSM/2X4-20MA/12-42DC/-3M [D3LCP] Display](https://omansevenstar.com/wp-content/uploads/2026/11/moore-industries-hdm-hsm-2x4-20ma-12-42dc-3m-d3lcp-humidity-temperature-display-module.webp)
Reviews
There are no reviews yet.