Danfoss 034L0058 KVL 22 Crankcase Pressure Regulator, 22 mm

Description

KVL 22: a crankcase pressure regulator that protects the compressor from overload

Danfoss 034L0058 is a KVL 22 crankcase pressure regulator with 22 mm (7/8 in) ODF solder connections. It limits the pressure at the compressor inlet to a set maximum, so that after a defrost or a long off period the motor is not overloaded by a high suction pressure. The range is 0.2 to 6 bar (3 to 87 psig) with a factory setting of 2 bar (29 psig).

The valve closes when the pressure after it rises above the setting. Kv is 3.2 m3/h at a proportional band of 2 bar, the maximum working pressure is 18 bar (260 psig) and the medium temperature range is -60 to 130 C. UL, EAC and UA approvals are listed.

Technical specifications

Parameter Specification
Danfoss code number 034L0058
Type KVL 22
Approvals as listed C UL US LISTED; EAC; RoHS; RoHS China; UA
Factory setting 2 bar
Inlet connection type Solder, ODF
Inlet size 7/8 in / 22 mm
Kv value 3.2 m3/h
Maximum test pressure 19.8 bar
Maximum working pressure 18 bar
Medium temperature range -60 C to 130 C
Oil free refrigerants R1234ze(E); R513A
Outlet connection type Solder, ODF
Outlet size 7/8 in / 22 mm
P band max. 2 bar
Rated capacity R404A/R507A 6.3 kW
Rated capacity R134a 5.3 kW
Rated capacity R22 7.1 kW
Rated capacity R407C 6.5 kW
Refrigerants R1234yf; R1234ze(E); R1270; R134a; R22; R290; R404A; R407A; R407C; R407F; and others listed in the data sheet
Regulation range 0.2 bar to 6 bar
UL approved refrigerants R134a; R22; R404A; R407A; R407C; R407F; R407H; R422B; R422D; R448A; and others listed in the data sheet
Net weight 0.368 kg
EAN 5715162265161

Protecting compressors after defrost and start-up

A KVL sits in the suction line in front of the compressor. After a defrost or a restart the evaporator may be warm, and gas at a high density would load the motor excessively. The KVL throttles the flow until the pressure falls to a safe value, so a smaller motor can be selected or an existing motor can be protected.

Listed capacities at the stated conditions are 6.3 kW on R404A/R507A, 5.3 kW on R134a, 7.1 kW on R22 and 6.5 kW on R407C; R1234ze(E) and R513A are listed for oil-free use. The Danfoss data sheet gives capacity curves against pressure drop.

Fitting and checks before ordering

Install in the suction line with the arrow in flow direction, close to the compressor, and set the pressure with the spindle while watching a gauge. Wrap the body in a wet cloth when brazing. A KVL does not control the evaporator; for that, use a KVP.

The page lists 034L1065 as an identical product and the customer part number 00A386. Confirm refrigerant, pressure setting, connection size and capacity before ordering, and check the compressor manufacturer maximum suction pressure.

Other types and sizes from the same Danfoss family that appear in the Danfoss store listing include KVL 12 (034L0041), KVL 15 (034L0042), KVL 28 (034L0046), KVL 35 (034L0052), KVL 10 (034L1180). These are listed for orientation only; each has its own datasheet values, so check size, connection and version before ordering.

Related Danfoss products: Danfoss 027H2308 ICSH 25 Dual-Position Servo Valve, 25 mm, Danfoss 027H2081 ICS3 25-10 Pilot-Operated Servo Valve, 25 mm, Danfoss 034L1075 KVP 22 Evaporator Pressure Regulator, 22 mm, Danfoss 034N0084 CPCE 22 Hot Gas Bypass Capacity Regulator and Danfoss 148H3402 ORV 40 Oil Temperature Regulating Valve, 40 mm.

How the KVL regulates

According to the Danfoss KVL data sheet, the crankcase pressure regulator opens on a pressure fall on the outlet side, that is, when the suction pressure ahead of the compressor drops below the set value. The KVL regulates on the outlet pressure only. Pressure variations on the inlet side do not affect the degree of opening, because the valve uses equalization bellows. A damping device protects the regulator against the pressure pulsations normally found in a refrigeration system, and the internal parts include a setting screw, main spring, valve plate and valve seat under a protective cap.

Danfoss notes that, because optimum operation of the plant is best reached with the KVL fully open, the term offset is not normally used in connection with this valve. In practice the regulator only throttles during the critical periods after a long standstill or after defrost, and is fully open in normal running.

Technical data from the data sheet

  • Regulating range: 0.2 to 6.0 bar, factory setting 2 bar
  • Maximum working pressure PS/MWP: 18 bar; maximum test pressure Pe: 19.8 bar
  • Medium temperature range: −60 to 130 °C
  • Maximum P-band (KVL 12 to 22): 2 bar
  • Kv value with maximum P-band (KVL 12 to 22): 3.2 m³/h
  • Rated capacity of the KVL 12 to 22 sizes: 7.1 kW (R22), 5.3 kW (R134a), 6.3 kW (R404A/R507) and 6.4 kW (R407C), at suction temperature −10 °C, condensing temperature 25 °C, 0.2 bar pressure drop and 0.6 bar offset

Sizing and noise

Danfoss warns that the connection dimension must not be too small, because gas velocities above 40 m/s at the regulator inlet can cause flow noise. For refrigerants or conditions other than the rated ones, Danfoss recommends selecting with its Coolselector®2 software. Spare parts listed for the KV range include a service kit with cap, gasket and screw, and a counter (locking) screw for KV 12, 15 and 22. Send us the refrigerant, compressor capacity and the maximum suction pressure allowed by the compressor maker, and we can confirm the selection.

Documents and quotation

Attached for download: Danfoss Crankcase pressure regulator, KVL AI555531791071en-000101 (manufacturer, unaltered), the manufacturer’s unaltered PDF. Browse comparable products in regulators. To order, send us 034L0058 and the required quantity; Seven Star LLC is an independent supplier based in Muscat.

Datasheets & Documents
  • PDF Datasheet Danfoss Crankcase pressure regulator, KVL AI555531791071en-000101 (manufacturer, unaltered) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.

Danfoss company profile

Founded 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966)
First product Thermostatic expansion valve for refrigeration
Headquarters Nordborg, Denmark
Ownership Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family
Size About 42,000 employees (2023)
Business segments Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics)
Brands in the group VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls

Milestones

  • 1932–1933: First expansion valve; the company is founded in Nordborg.
  • 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
  • 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
  • 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
  • 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
  • 2021: Acquisition of Eaton's hydraulics business.

Choosing Danfoss products

For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.

Where Danfoss products are used

In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.

Danfoss products we list

Family Examples
Variable speed drives and soft starters VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter
Solenoid valves and coils EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil
Pressure switches and thermostats KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101
Pressure transmitters MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2
HVAC and refrigeration valves AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element

Ordering Danfoss products: what we need

Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.

Facts checked against Danfoss's company history pages and published company data, October 2026.

Frequently Asked Questions

What is Danfoss 034L0058?
A KVL 22 crankcase pressure regulator with 22 mm (7/8 in) ODF connections.
What does it limit?
The pressure at the compressor inlet, to avoid motor overload after defrost or start-up.
What is the setting range?
0.2 to 6 bar (3 to 87 psig), factory set to 2 bar.
What are the limits?
18 bar maximum working pressure and -60 to 130 C medium temperature.
Which document is attached?
The Danfoss crankcase pressure regulator KVL data sheet AI555531791071en-000101.