Danfoss 148B0084 SNV-ST Gauge Stop Needle Valve, G 1/2 A
Description
SNV-ST: a steel stop needle valve for gauges and instruments
The 148B0084 is an SNV-ST stop needle valve (also called a gauge valve) with G 1/2 A external threads to ISO 228-1 at both ends and a steel body. A needle seat gives tight shut-off and fine control in a small bore, and the angleway body carries a cap. Net weight is 0.39 kg.
The ratings are a maximum working pressure of 140 bar (2030 psig) and a temperature range of -60 to 150 C. The valve is bi-flow, carries EAC, TUV and UA approvals and is part of the SNV family with its own accessories and spare parts. The page lists 148B3880 as an identical product.
Technical specifications
| Parameter | Specification |
|---|---|
| Danfoss code number | 148B0084 |
| Type | SNV-ST |
| Approvals as listed | EAC; TÜV; UA |
| Body material | Steel |
| Connection standard | ISO 228-1 |
| Inlet connection size | 1/2 A |
| Inlet connection type | G |
| Inlet Internal/External | External |
| Maximum working pressure | 140 bar |
| Outlet connection size | 1/2 A |
| Outlet connection type | G |
| Outlet Internal/External | External |
| Refrigerants | R113; R114; R1150; R1233zd(E); R1234yf; R1234ze(E); R125; R1270; R1336mzz(Z); R134a; and others listed in the data sheet |
| Temperature range | -60 C to 150 C |
| Net weight | 0.39 kg |
| EAN | 5715162458464 |
Gauge isolation and instrument connections
In a refrigeration plant the SNV isolates pressure gauges, transmitters, pressure switches and sampling points from the process. The 140 bar rating is far higher than the 52 bar of the plant valves, so it never limits an instrument branch. The G 1/2 A thread matches many gauge and transmitter connections.
The ST version has the standard steel construction; the SS version is stainless with NPT threads (a separate code). The needle stem can also throttle a small bypass, for example to dampen pulsation in front of a gauge. Because the valve is bi-flow, it does not matter which end is connected to the process, which simplifies the installation of gauge manifolds.
Installation and ordering checks
Seal the G threads with a flat-faced seal or a bonded washer as shown in the installation guide; do not use thread tape on the sealing face. Support the instrument weight so that the valve is not bent. Close the valve by hand and re-open slowly to avoid pressure shocks on the instrument.
Confirm the thread (G 1/2 A here), the material (steel) and the pressure class before ordering. The data sheet for SNV-ST / SNV-SS gives dimensions and weights.
Treat the valve as an isolating device only for instruments; do not use it for continuous throttling of process flow, and replace the cap after each use so that the thread and the needle seat stay clean.
Documents and quotation
For the full drawings, ordering tables and wiring or piping details, open the attached Danfoss Gauge valve, SNV-ST / SNV-SS AI554838288553en-000101 (manufacturer, unaltered) (manufacturer PDF, unaltered). More items of this kind are listed under globe and stop valves. Seven Star LLC supplies from Muscat as an independent supplier: ask for a quotation on 148B0084.
Datasheets & Documents
- Datasheet Danfoss Gauge valve, SNV-ST / SNV-SS AI554838288553en-000101 (manufacturer, unaltered) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
Related products
Frequently Asked Questions
An SNV-ST steel stop needle valve with G 1/2 A external threads for gauges and instruments.
A maximum working pressure of 140 bar (2030 psig).
-60 to 150 C.
The product page lists 148B3880 as identical.
The Danfoss SNV-ST / SNV-SS data sheet AI554838288553en-000101.