Brand:

AMETEK Chatillon DG-250KG Mechanical Force Gauge 250 kgf

Description

Kilograms-force on the dial: AMETEK Chatillon DG-250KG

Plenty of specifications in Gulf workshops still quote loads in kilograms-force: lifting accessories, hand-tool effort limits, older equipment manuals. The AMETEK Chatillon DG-250KG suits those with a dial graduated 250 x 1.25 kgf. It is the larger of the two kilogram models in the DG Series, the other being DG-100KG at 100 x 0.50 kgf.

Specification list for DG-250KG

Parameter Value
Part number DG-250KG
Series Chatillon DG mechanical force gauge
Capacity and graduation 250 x 1.25 kgf
Unit of measure Kilograms-force (kgf)
Dial 2.25 inch concentric dial, peak hold switch, tare ring
Accuracy Plus or minus 0.5 percent of full scale
Overload capacity 110 percent of rated capacity
Maximum overload 150 percent of rated capacity
Tare capacity 10 percent of rated capacity
Deflection at full scale 10 mm (0.394 inch)
Operating temperature 40 to 110 F (5 to 45 C)
Instrument weight 4.7 lb (2.2 kg)
Shipping weight 8.4 lb (3.80 kg)
Mounting holes #10-32 UNF (4 places)
Shaft thread 5/16-18 UNC, 0.38 inch long, both ends

From the Chatillon DG Series data sheet.

Understanding the numbers

250 kgf is roughly 551 lbf or 2.45 kN, which sits at the very top of the series capacity stated by the manufacturer as 500 lbf (2.5 kN). Each graduation is 1.25 kgf, and accuracy is plus or minus 0.5 percent of full scale, equal to 1.25 kgf. Overload capacity of 110 percent is 275 kgf and the maximum overload of 150 percent is 375 kgf. The tare ring handles up to 10 percent, or 25 kgf.

How DG-250KG differs from other DG variants

  • DG-100KG reads 100 x 0.50 kgf, so it is more precise for loads below 100 kgf.
  • DG-250KG reads 250 x 1.25 kgf, giving 2.5 times the range.
  • DG-500 reads 500 x 2.5 lbf; 500 lbf equals about 227 kgf, so DG-250KG has slightly higher capacity in physical terms.
  • DG-1000N and DG-2500N cover the same force band in newtons: 2500 N is about 255 kgf.

Choose DG-250KG only when your site documents use kgf, to avoid conversion mistakes.

Features

The 2.25 inch dial reads clockwise only and rotates 360 degrees for taring, the peak hold switch captures maximum values, and a mechanical overload feature protects the movement. The manufacturer lists Intrinsically Safe and NIST calibration with data, plus a two year warranty. The plastic housing weighs 4.7 lb (2.2 kg) and ships at 8.4 lb (3.80 kg).

Mounting and accessory fit

The case has #10-32 UNF mounting holes in four places, and the shaft has 5/16-18 UNC thread 0.38 inch long at each end. Because the capacity of DG-250KG is close to the top of the series, the heavier accessory set marked for the 5/16-18F thread, such as SPK-FMG-012C stationary hook and SPK-FMG-011B flat adapter, is likely what you need; confirm with us before ordering.

Typical applications

Examples include proof loading of small lifting points, checking the effort needed to operate a manual valve or damper handle, verifying the pull of door closers and clamps, and compression of springs and seals. Handheld use with the optional handle set is possible, or you can fit it to the MT500 mechanical test stand for repeatable results.

Calibration, handling and supplier note

Check zero before each session, avoid shock loading past 375 kgf, and calibrate at the interval your quality system requires. The certificate of calibration with NIST data arrives with the gauge according to the data sheet. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Conversions and verification for DG-250KG

Use 1 kgf = 9.80665 N when you need a cross-check. The full-scale value of 250 kgf is 2452 N, and one graduation of 1.25 kgf is 12.26 N. A practical verification is to suspend certified masses from the hook through a fixed frame, for example a 100 kg mass reading 100 kgf, then compare the dial reading with the stated accuracy of 1.25 kgf. At 25 kgf, the tare ring limit, you can zero out the weight of a fixture such as a sling or a plate and then read only the specimen load.

Where kilogram-force instruments are still specified

Older lifting-tackle test sheets, hand-tool effort limits, mechanical maintenance manuals and some regional standards express load in kgf. Using DG-250KG prevents the arithmetic and rounding that occur when a technician converts newtons or pounds on the shop floor. When your documents move to SI units, the newton versions DG-1000N and DG-2500N are the direct successors, but they are different part numbers with different graduations, so plan the changeover in your inspection procedures rather than swapping a gauge silently.

Handling and storage of DG-250KG

Weighing 4.7 lb, DG-250KG is best carried in its protective case. The data sheet states the case and a set of stainless steel attachments come with a DG gauge. Store with no load applied to the shaft and avoid temperatures outside 40 to 110 F, which is the stated operating range. After use, wipe the housing and hooks, and check that the peak hold switch returns the needle smoothly to zero.

Ordering notes for DG-250KG

State in the RFQ whether you want only the gauge or also fittings. The long accessory list for the series contains hooks, adapters, V-notch fixtures, a grasping cable and a handle assembly, each with its own part number. Tell us if the gauge will be hand-held or stand-mounted, and give the delivery location in Oman or the GCC so that availability and shipping can be planned in one reply.

Documents and quotation

The DG Series data sheet is attached. Send an RFQ with part number DG-250KG, quantity and accessory list.

Selection Notes for the AMETEK DG-250KG

When comparing the AMETEK DG-250KG with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the AMETEK portable test & measurement range and confirm the correct order code before you commit.

Datasheets & Documents
  • PDF Datasheet AMETEK Chatillon DG-250KG Mechanical Force Gauge 250 kgf Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.

Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.

AMETEK company profile

Established 1930, USA, as American Machine and Metals; later renamed AMETEK
Headquarters Berwyn, Pennsylvania
Structure Two groups: Electronic Instruments (EIG) and Electromechanical (EMG)
Process brands Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex

Milestones

  • 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
  • Early 1960s: The company is renamed AMETEK.
  • 2021: AMETEK acquires Magnetrol.

AMETEK products we list

Product Type Typical use
888, 900, 930 Western Research sulfur recovery analysers Tail gas, air demand and H2S in sulfur pits on Claus units
931, 933, 9900RM/WM UV gas analysers H2S in natural gas and multi-component process streams
5000, 3050-OLV, 5100HD, 5100P Moisture analysers Water content in natural gas and process gases; the 5100 models use TDLAS
241CE II, Chanscope II / Model 13 Dew point analysers and testers Hydrocarbon and water dew point of natural gas
WDG 1200/1210, WDG-V, TM2000 Thermox oxygen analysers Combustion control on heaters and boilers, and trace oxygen
SPOT+, Cyclops L Land pyrometers Non-contact temperature of furnaces, kilns, tubes and hot metal
120HD, Ranarex, Drexelbrook RCT-1210 Portable analysers and level Hydrogen purity in generators, gas specific gravity, RF level measurement

Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.

Where AMETEK instruments are used

In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.

Ordering AMETEK products: what we need

Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.

Facts checked against AMETEK company history, October 2026.

FAQ

Questions about the AMETEK Chatillon DG-250KG Mechanical Force Gauge

Answers from our engineering team on installation, compatibility and integration.

01What does DG-250KG read?
DG-250KG reads 250 x 1.25 kgf, graduated in kilograms-force.
02How accurate is DG-250KG?
Plus or minus 0.5 percent of full scale, equal to 1.25 kgf on this range.
03What is the maximum overload for DG-250KG?
150 percent of rated capacity, which is 375 kgf.
04How does DG-250KG differ from DG-500?
DG-250KG is graduated in kgf at 250 x 1.25 kgf; DG-500 is graduated in lbf at 500 x 2.5 lbf.
05What details are needed for an RFQ on DG-250KG?
The part number DG-250KG, quantity and accessories such as hooks, adapters and handle assembly.