Endress+Hauser CML18 Liquiline Mobile Memosens Handheld

Description

CML18 Liquiline Mobile: Memosens in your shirt pocket

Endress+Hauser CML18 is a compact multiparameter handheld that reads digital Memosens sensors in the field or laboratory. Weighing only 155 g with a 86 by 54 by 48 mm body, it connects to a sensor either directly through its Memosens coupling or through an M12 cable, and it can be operated from the keys, from the SmartBlue app or from the Memobase Pro app over Bluetooth LE. Because the same Memosens technology is used in the process, the datasheet claims complete consistency between process and sample measurements.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. The datasheet is TI01598C, edition 03.25-00.

CML18 technical data

Parameter Value
Measured variables pH, ORP, pH/ORP, oxygen, conductivity, temperature
Sensor inputs Direct Memosens connection or M12 for CYK10 or CYK20 cable; one sensor at a time
Output Memosens M12, up to 80 mA
Battery 1000 mAh, minimum 950 mAh; up to 48 h with adapted energy settings
Charging Qi wireless 5 W (power supply at least 1500 mA) or M12 USB 5 V, 0.6 A
Ambient Operation minus 10 to 60 degrees C; charging 0 to 45 degrees C
Storage Minus 20 to 45 degrees C; humidity 0 to 95 percent
Protection IP66; impact IK06 (1 J)
Data logger More than 10,000 measured values with time and date
Dimensions and weight 86 x 54 x 48 mm; 155 g
Materials PBT housing, PMMA window, TPE buttons and cap, nickel-plated CuZn M12 connection
Display languages 15, including English, German, Spanish, French, Russian, Chinese and Portuguese
Wireless Bluetooth LE; radio approvals for Europe, USA, China, Canada, Japan, South Korea, Brazil, Mexico, Singapore, Argentina, Thailand, Australia, Indonesia

Daily use features

The measuring screen scrolls with the Next button and stores the current values as a grab sample with the Select button. A long press of the Next key opens the menu, and a hold of more than seven seconds forces a hardware reset until the green LED lights and the device restarts. Pre-calibrated Memosens sensors can be swapped in seconds, which the maker describes as real plug and play between parameters, and calibration can be done in the laboratory to increase process availability.

How CML18 differs from fixed transmitters

Liquiline CM42B, CM442, CM444 and CM448 are installed field or rail transmitters with several channels, relay outputs and fieldbus. CML18 is a one-sensor battery-powered meter with no process outputs; it is meant for grab samples, verification of installed sensors and calibration. It does not supply power to a process loop and it measures one sensor at a time, so it complements rather than replaces the permanent measuring point.

Sensors that pair with CML18

The datasheet lists compatible Memosens sensors, and the laboratory range such as the CPL51E pH probe, the CLL47E four-electrode conductivity probe and the COL37E optical oxygen sensor is designed for it. Process Memosens sensors can be connected through the CYK10 or CYK20 cable. Memobase Plus CYZ71D software supports laboratory calibration records.

Apps, data and languages on CML18

Beyond the two-button menu, the CML18 accepts operation and configuration from a smartphone or tablet over Bluetooth LE using the SmartBlue app or the Memobase Pro app, so the operator can use a larger screen for commissioning. The data logger stores more than 10,000 measured values with time and date stamps, which can be read out over the USB cable or by Bluetooth. The display rotates automatically, which helps when the device is held in either hand, and fifteen languages are offered including Arabic-region favourites such as English, French and Russian alongside German, Spanish, Chinese and Japanese.

Sensor data stay in the Memosens sensor itself: total operating hours, hours at extreme values or high temperatures, the number of steam sterilisations and the condition of the sensor, which supports predictive maintenance of fixed sensors that are brought to the lab for checking.

Practical tips from the datasheet

  • Charge only within 0 to 45 degrees C; elevated storage temperatures reduce battery capacity.
  • Operation is interrupted while log data are read out through a cable or while firmware updates run.
  • Keep the protective cap on the Memosens connection when not in use.
  • Use Qi-certified chargers of at least 5 W output.
  • Note that the battery contains an SVHC substance in a quantity above 0.1 percent, which is not hazardous in designated use.

Typical users in Oman and the Gulf

Water quality teams at utilities, laboratories at desalination and power plants and consultants checking effluent compliance all benefit from one device that covers pH, ORP, oxygen and conductivity. The ability to send data to a smartphone also speeds up reporting.

CML18 questions answered briefly

Which parameters does Endress+Hauser CML18 measure? pH, ORP, combined pH and ORP, oxygen, conductivity and temperature, depending on the connected Memosens sensor.

How is the CML18 powered and how long does the battery last? A 1000 mAh battery charged by Qi wireless charging at 5 W or through the M12 USB cable at 5 V, with up to 48 hours of life using adapted energy settings.

Can CML18 be used with a smartphone? Yes, via Bluetooth LE with the SmartBlue or Memobase Pro apps for operation, configuration, data analysis and transmission.

How many sensors can CML18 connect at once? One; the datasheet states that simultaneous connection of two sensors is not supported.

How rugged is the CML18? It has IP66 protection, an impact rating of 1 J (IK06), operation from minus 10 to 60 degrees C and a weight of 155 g.

Documents and quotation

The datasheet for CML18 is attached to this page. Send an RFQ with CML18, the cables and sensors required and the quantity, and we will reply with a quotation.

Datasheets & Documents
  • PDF Datasheet Endress+Hauser CML18 Liquiline Mobile Memosens Handheld Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser CML18 Liquiline Mobile Memosens

Answers from our engineering team on installation, compatibility and integration.

01Which parameters does Endress+Hauser CML18 measure?
pH, ORP, combined pH and ORP, oxygen, conductivity and temperature, depending on the connected Memosens sensor.
02How is the CML18 powered and how long does the battery last?
A 1000 mAh battery charged by Qi wireless charging at 5 W or through the M12 USB cable at 5 V, with up to 48 hours of life using adapted energy settings.
03Can CML18 be used with a smartphone?
Yes, via Bluetooth LE with the SmartBlue or Memobase Pro apps for operation, configuration, data analysis and transmission.
04How many sensors can CML18 connect at once?
One; the datasheet states that simultaneous connection of two sensors is not supported.
05How rugged is the CML18?
It has IP66 protection, an impact rating of 1 J (IK06), operation from minus 10 to 60 degrees C and a weight of 155 g.