- Vibration Monitoring
- Industrial Communications
- PLC & I/O Cards
- Automation Accessories
- AC Drives
- Controllers & Data Acquisition
- Industrial Computers
- Encoders
- Safety Switches & Guard Locking
- CCTV & Security
- Isolator & Barrier
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Automation Software
- Servo Drives
- Robotics
- Machine Vision
Brand: AMETEK
AMETEK 300-8707 Copper Hollow Cathode Lamp (Cu HCL)
Description
Overview
The AMETEK 300-8707 is a copper hollow cathode lamp built as the light source for atomic absorption spectroscopy (AAS) instruments measuring copper concentration in a sample. As a consumable, application-specific component, it supplies the precise 324.8 nm wavelength light that copper atoms in a flame or graphite furnace absorb, which AAS instruments use to determine copper concentration in the sample being analyzed. Copper is one of the most frequently measured elements in AAS work, so the copper lamp is often the most heavily used lamp in a laboratory’s collection.
As a genuine AMETEK-manufactured single-element lamp, the AMETEK 300-8707 is built to the precise optical and electrical tolerances AAS instrument manufacturers specify for reliable, repeatable analytical results. Seven Star LLC supplies the AMETEK 300-8707 copper hollow cathode lamp to environmental, water-quality, metallurgical, petroleum and food-testing laboratories across Muscat, Sohar, Salalah and the wider GCC.
Operating Principle
Inside the lamp, a copper cathode is bombarded with ions from a low-pressure inert fill gas under an applied current, causing copper atoms to be sputtered from the cathode surface and excited to emit light at copper’s characteristic 324.8 nm wavelength. This narrow, element-specific emission line is what an AAS instrument’s optical path passes through the sample; copper atoms present in the sample absorb a portion of this light in direct proportion to their concentration, letting the instrument calculate a precise copper reading.
The 324.8 nm line is copper’s primary resonance line and gives strong sensitivity for trace work. Because the lamp emits only copper lines and the atomized sample absorbs only at matching wavelengths, the measurement is highly selective even in complex matrices such as digested alloys, oils or food samples. As with any hollow cathode lamp, a short warm-up period lets the emission stabilize before calibration, and the lamp current set in the instrument software is a balance between signal strength and service life.
Engineering Design of the AMETEK 300-8707
The AMETEK 300-8707 uses a quartz window, chosen for its transparency to the 324.8 nm emission wavelength copper analysis requires, and is filled with an inert gas (typically neon or argon) to sustain the sputtering discharge that excites the copper cathode. It follows the standard 1.5-inch (37 mm) lamp diameter and connector format common across AAS instruments designed for this hollow cathode lamp family, simplifying compatibility across common AAS instrument brands.
Lamp output declines gradually over its working life as cathode material is consumed, so heavily used copper lamps are typically replaced more often than lamps for rarely tested elements. To get the most from each lamp, operators should avoid running it above the recommended current, keep the quartz window clean, and allow it to cool before removal. Keeping a sealed spare AMETEK 300-8707 on the shelf ensures that routine copper testing can continue immediately when the in-service lamp reaches the end of its life.
Key Features
The AMETEK 300-8707 provides a dependable copper source for everyday AAS analysis:
- It is a genuine AMETEK single-element copper hollow cathode lamp.
- It emits the copper-specific 324.8 nm primary resonance line.
- A quartz window provides high transmission at the copper analytical wavelength.
- An inert fill gas sustains a stable sputtering discharge at the copper cathode.
- The standard 1.5-inch (37 mm) diameter format suits AAS instruments designed for this lamp family.
- Precision manufacture supports consistent, repeatable analytical results between lamps.
- It serves as a direct replacement wherever the AMETEK 300-8707 is specified.
- Strong single-element emission supports both flame and graphite furnace copper methods.
Industrial Applications
The AMETEK 300-8707 copper hollow cathode lamp is used in environmental testing laboratories, water-quality monitoring facilities and industrial quality-control labs across Muscat, Sohar and Salalah that run atomic absorption spectroscopy for trace-metal analysis, including copper testing in drinking water, wastewater, soil and food and beverage samples. Copper in potable water is often linked to corrosion of copper plumbing, making it a regular parameter for water utilities and building operators.
Beyond environmental work, copper is measured in metallurgical and mining laboratories analyzing ores and alloys, in plating and metal-finishing baths, and in petroleum laboratories testing fuels and lubricating oils, where copper content can indicate bearing or cooler wear. Across these GCC sectors the AMETEK 300-8707 is a routine consumable replacement item, since lamp output gradually degrades with use and must be replaced to maintain analytical accuracy and pass laboratory quality-control checks. Seven Star LLC supplies genuine lamps to laboratories throughout Oman and the GCC, including those in the Sohar and Salalah industrial zones.
Laboratories can monitor the condition of the AMETEK 300-8707 through routine checks of emission energy, baseline noise and calibration sensitivity. A steady decline in energy, noisier baselines or difficulty achieving the expected characteristic concentration are typical signs that the copper lamp should be replaced. Logging lamp hours alongside these checks helps quality managers plan replacements before copper results are affected, which is especially important in accredited laboratories that must demonstrate continuous method performance.
Technical Specifications
The AMETEK 300-8707 is supplied to the following specification:
| Parameter | Specification |
|---|---|
| Model | AMETEK 300-8707 |
| Lamp Type | Single-element hollow cathode lamp (HCL) |
| Element | Copper (Cu) |
| Emission Wavelength | 324.8nm |
| Window Material | Quartz |
| Fill Gas | Inert (neon/argon) |
| Diameter | 1.5in (37mm) |
| Application | Atomic absorption spectroscopy (flame / graphite furnace) |
Request a Quote for AMETEK 300-8707
To order the AMETEK 300-8707 copper hollow cathode lamp, send Seven Star LLC a formal RFQ with the quantity and your AAS instrument make and model so we can confirm compatibility. Our instrumentation division will confirm current availability, provide the product documentation and quote delivery to any site in Oman and the GCC. Contact us for pricing and availability on this lamp and other AAS consumables.
Browse the full AMETEK range or see more Liquid Analytical Accessories products supplied by Seven Star LLC in Oman and the GCC.
Reviews (0)
How would you rate this product? Cancel reply
About brand
Process analyzers for sulfur recovery, moisture and combustion are the AMETEK products most often requested by gas plants and refineries. AMETEK, a US instrument manufacturer founded in 1930 and based in Berwyn, Pennsylvania, sells them under names such as Western Research, Thermox and Drexelbrook. Seven Star LLC lists AMETEK gas analyzers, analyzer spare parts and level transmitters, and sources them for process plants in Oman.
AMETEK analyzers and parts listed
The AMETEK products on this page include:
- 5100HD and the transportable 5100P: tunable diode laser (TDLAS) analyzers, used for example for moisture in natural gas
- 3050-OLV: process moisture analyzer, with spare boards such as 305110902S
- Thermox WDG-V: flue gas oxygen analyzer for combustion control
- Western Research 900 air demand analyzer and 930 analyzer for H2S in sulfur pits
- Drexelbrook RCT-1210 RF level transmitter
- Spare parts: PCB assemblies, a protected gold mirror and hollow cathode lamps
Where AMETEK analyzers are used
The 900 air demand analyzer sits on the tail gas of a Claus sulfur recovery unit and measures H2S and SO2 so the air to the reaction furnace can be trimmed. The 930 watches the vapor space of the sulfur pit. Moisture analyzers such as the 3050-OLV and 5100HD serve gas dehydration, pipeline and LNG feed gas, and the Thermox WDG-V measures excess oxygen on fired heaters and boilers. These duties are common in gas processing and refining across the GCC.
Ordering AMETEK analyzers and spares: what we need
For spare parts, send the AMETEK part number, the analyzer model and its serial number. Boards and optical parts change with analyzer revision, and the serial number lets the build be checked in the manufacturer's records. For a new analyzer we need the stream composition, the component and range to be measured, sample pressure and temperature, area classification, power supply, outputs and whether a sample system or shelter is included. For Drexelbrook level transmitters give the full model number, the probe length and the process material.
Browse AMETEK products by category: Gas Analyzer Accessories, Gas Analyzer Systems, Liquid Analytical Accessories, Level Transmitter.
Related products
Frequently Asked Questions
This product functions as a highly stable light source that emits the exact spectral lines of Copper (Cu). It is used exclusively in Atomic Absorption (AA) spectrometers to measure the concentration of copper in various analytical samples.
By utilizing a pure copper cathode and superior gas sealing, the AMETEK 300-8707 guarantees high-intensity light output with minimal background noise, significantly lowering the limit of detection (LOD) for trace analysis.
Seven Star LLC is a premier independent industrial supplier and specialist B2B procurement consultant in Oman. We source and supply original, genuine equipment from leading global OEMs like AMETEK to support regional laboratories and engineering facilities.
Send the model number, required quantity and delivery location through the quote request form or by email to Seven Star LLC. The sales team replies with availability, lead time and commercial terms for your Oman or GCC project.
Provide the full model or part number, quantity, the application and any required options or certifications. This lets the team confirm the exact configuration and avoid ordering a wrong variant.

Reviews
There are no reviews yet.