- Machine Vision
- Automation Software
- Robotics
Brand: AMETEK
AMETEK Chatillon LG-20N Mechanical Force Gauge 20 N
Description
A metric gauge: AMETEK Chatillon LG-20N
Many laboratories and factories in the Gulf work to ISO and DIN methods that specify forces in newtons. The AMETEK Chatillon LG-20N answers that need directly. It is the newton-graduated LG Series gauge with a 20 N capacity and 0.10 N graduations, written in the ordering table as 20 x 0.10 N. There is no conversion factor to apply, and the dial is printed in the same unit as the test standard.
LG-20N data sheet values
| Parameter | Value |
|---|---|
| Part number | LG-20N |
| Series | Chatillon LG mechanical force gauge |
| Capacity and graduation | 20 x 0.10 N |
| Unit of measure | Newtons (N) |
| Dial | 2.25 inch concentric dial, reads clockwise, rotates 360 degrees for taring |
| Accuracy | Plus or minus 0.5 percent of full scale |
| Overload capacity | 110 percent of rated capacity |
| Maximum overload | 150 percent of rated capacity |
| Tare capacity | 10 percent of rated capacity |
| Dial resolution | 0.5 percent of full scale |
| Deflection at full scale | 10 mm (0.394 inch) |
| Operating temperature | 40 to 110 F (5 to 45 C) |
| Instrument weight | 1.5 lb (0.67 kg) |
| Shipping weight | 3.5 lb (1.59 kg) |
| Mounting | M3 x 0.5 holes (4 places), #10-32 holes (2 places) |
From the Chatillon LG Series data sheet.
Practical meaning of a 20 N range
Twenty newtons is about two kilograms-force, or roughly 4.5 lbf. The gauge therefore suits forces such as the opening force of a snap lid, the retention of a connector latch, the peel force of a seal, or the tripping force of a micro switch. The 0.5 percent of full scale accuracy corresponds to 0.1 N, equal to one graduation. Overload capacity is 110 percent (22 N) and maximum overload 150 percent (30 N), and the tare ring takes out up to 10 percent of capacity, 2 N.
How LG-20N differs from other metric and imperial LG gauges
- LG-10N: 10 x 0.05 N, half the span of LG-20N.
- LG-20N: 20 x 0.10 N.
- LG-30N: 30 x 0.15 N.
- LG-50N: 50 x 0.25 N.
- LG-100N to LG-500N: 100 x 0.50 N up to 500 x 2.50 N.
Note that LG-010 in pounds-force reads 10 lbf, which is larger than 20 N (10 lbf is about 44.5 N), so the unit printed on the dial matters more than the number when comparing ranges.
Features and construction
LG-20N has the standard LG layout: a 2.25 inch concentric dial that reads clockwise only and rotates 360 degrees for taring, a peak hold button, a plastic housing that sits comfortably in the hand, and a mechanical overload stop. The manufacturer lists Intrinsically Safe and NIST calibration with data among its features, with a two year warranty. Instrument weight is 1.5 lb (0.67 kg) and shipping weight 3.5 lb (1.59 kg). Full-scale deflection is 10 mm.
Test practice for newton ranges
Read the peak hold needle after the specimen releases, then press the button to reset. Start with the needle at zero or tare against any fixture, and keep the pull direction aligned with the shaft. Small-force tests are sensitive to speed: pulling quickly overshoots the peak, so draw at a steady, slow pace and repeat at least three times. For comparisons between sites, use the same adapter from the accessories list, for example the flat adapter SPK-FMG-011A or the point adapter SPK-FMG-009A.
Fitting to a stand and handle options
The case accepts M3 x 0.5 screws (4 places) and #10-32 screws (2 places) for stand mounting, and the shaft has #10-32 thread 3/16 inch long at both ends. A handle assembly SPK-FMG-HANDLE and carrying case NC002710 are listed accessories.
Converting and cross-checking
If you need to cross-check LG-20N against an imperial instrument, use 1 lbf = 4.448 N. Twenty newtons is 4.50 lbf, and one graduation of 0.10 N is 0.0225 lbf. A deadweight check is simple: hang a 1 kg mass from the hook and the dial should indicate close to 9.81 N, within the stated accuracy of 0.1 N. Repeat with 2 kg for 19.6 N at the top of the range. Document the result in the calibration log with the serial number.
Metric-graduated gauges are particularly useful when your customer specifications, such as ISO test methods for packaging, closures and connectors, cite newtons. They avoid the transcription errors that come with converting each reading by hand.
Why choose a mechanical gauge
A mechanical gauge such as LG-20N needs no battery, no cable and no software, so it works in any workshop or field location and is unaffected by electrical noise. The manufacturer includes an Intrinsically Safe feature in the LG Series feature list, which suits some plant environments; check your own area classification rules and any certification wording before using it in a hazardous area. For data logging you would move to the digital DF series, but for go/no-go checks the dial and peak hold are quick and sufficient.
Quick selection guide around LG-20N
Use LG-20N when your typical forces lie between about 4 N and 16 N. Below that, LG-10N with its 0.05 N graduation is a better fit; above it, move to LG-30N or LG-50N. Check that the peak you expect never exceeds 22 N, the 110 percent overload capacity. Where the task is repeated many times per shift, mount the gauge on a stand to remove operator variation, and keep a spare gauge so the instrument can be sent for calibration without stopping the line. Include the gauge range, unit and serial number on the inspection record so that audits can trace each force check to a calibrated instrument. These simple habits cost little and make the data from LG-20N far easier to defend.
Documents and quotation
The LG Series data sheet is attached. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number LG-20N, quantity and accessories to receive availability.
Other Models in the Chatillon Lg Range
Seven Star LLC supplies models from the Chatillon Lg range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| AMETEK Chatillon LG-20N Mechanical Force Gauge 20 N | Portable Test & Measurement | You are viewing this model |
| AMETEK Chatillon LG-050 Mechanical Force Gauge 50 lbf | Portable Test & Measurement | View details |
| AMETEK Chatillon LG-010 Mechanical Force Gauge 10 lbf | Portable Test & Measurement | View details |
Datasheets & Documents
- Datasheet AMETEK Chatillon LG-20N Mechanical Force Gauge 20 N Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.
Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.
AMETEK company profile
| Established | 1930, USA, as American Machine and Metals; later renamed AMETEK |
|---|---|
| Headquarters | Berwyn, Pennsylvania |
| Structure | Two groups: Electronic Instruments (EIG) and Electromechanical (EMG) |
| Process brands | Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex |
Milestones
- 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
- Early 1960s: The company is renamed AMETEK.
- 2021: AMETEK acquires Magnetrol.
AMETEK products we list
| Product | Type | Typical use |
|---|---|---|
| 888, 900, 930 | Western Research sulfur recovery analysers | Tail gas, air demand and H2S in sulfur pits on Claus units |
| 931, 933, 9900RM/WM | UV gas analysers | H2S in natural gas and multi-component process streams |
| 5000, 3050-OLV, 5100HD, 5100P | Moisture analysers | Water content in natural gas and process gases; the 5100 models use TDLAS |
| 241CE II, Chanscope II / Model 13 | Dew point analysers and testers | Hydrocarbon and water dew point of natural gas |
| WDG 1200/1210, WDG-V, TM2000 | Thermox oxygen analysers | Combustion control on heaters and boilers, and trace oxygen |
| SPOT+, Cyclops L | Land pyrometers | Non-contact temperature of furnaces, kilns, tubes and hot metal |
| 120HD, Ranarex, Drexelbrook RCT-1210 | Portable analysers and level | Hydrogen purity in generators, gas specific gravity, RF level measurement |
Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.
Where AMETEK instruments are used
In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.
Ordering AMETEK products: what we need
Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.
Facts checked against AMETEK company history, October 2026.
Browse AMETEK products by category: Gas Analyzer Accessories, Gas Analyzer Systems, Liquid Analytical Accessories, Level Transmitter.
FAQ
Questions about the AMETEK Chatillon LG-20N Mechanical Force Gauge 20 N
Answers from our engineering team on installation, compatibility and integration.
01What does LG-20N measure?
Force in newtons: LG-20N reads 20 x 0.10 N.
02What is the maximum safe overload for LG-20N?
110 percent overload capacity is 22 N, and the maximum overload is 150 percent, or 30 N.
03Is LG-20N a pull or push gauge?
The LG Series handles both tensile (pull) and compression (push) testing.
04How is LG-20N different from LG-010?
LG-20N is graduated in newtons (20 x 0.10 N) while LG-010 is graduated in pounds-force (10 x 0.05 lbf).
05What should my RFQ for LG-20N list?
The part number LG-20N, quantity and any adapters, hooks or handle you need.