ABB ACS880-01-05A6-3 Wall-Mounted Drive 2.2 kW 5.6 A
Description
A 2.2 kW industrial drive on a 400 V supply
ACS880-01-05A6-3 is the 400 V wall-mounted ACS880 type with 5.6 A nominal output. Nominal output is 5.6 A at 2.2 kW and the mechanical size is frame R1. Use cases include a packaging line axis and a test-rig or lab drive. Direct torque control, a built-in harmonic choke and Safe Torque Off come with the drive, which keeps the surrounding cabinet simple.
Technical specifications
| Parameter | Specification |
|---|---|
| Type designation | ACS880-01-05A6-3 |
| Series | ACS880-01, wall-mounted single drive, ACS880 industrial drive platform |
| Supply voltage | 3-phase 380 to 415 V (400 V table) |
| Nominal rating | 2.2 kW, 5.6 A |
| Light overload use | 2.2 kW, 5.3 A |
| Heavy-duty rating | 4 A = 1.5 kW |
| Maximum output current | 6.8 A |
| Frame size | R1 |
| IP55 size (H x W x D) | 450 x 162 x 292 mm; 8.1 kg |
| Noise level | 50 dB(A) |
| Power loss for cabinet design | 78 W (90% frequency, full current) |
| Cooling air flow | 44 m3/h |
| Brake chopper | Built in as standard (frames R1 to R4) |
| Brake resistor type | JBR-03, 80 ohm, 40 kJ |
| Minimum brake resistance | 78 ohm for 2.2 kW braking power |
| Optional sine filter | B84143V0006R229, 5.3 A, 2.2 kW |
Current ratings and installation size
ABB gives 5.3 A (2.2 kW) for light overload use and 4 A (1.5 kW) for heavy duty, against a nominal 5.6 A and a peak of 6.8 A. Light overload suits pumps and fans, whose torque falls with speed, while heavy duty is the choice for crushers, extruders and conveyors that need high starting torque. Start from the motor nameplate current, then verify derating for temperature, altitude and switching frequency.
Frame R1 in IP21: height 409 mm including the cable box and 370 mm without, width 155 mm, depth 226 mm, mass 7 kg. For harsher rooms ABB offers IP55 at 450 x 162 x 292 mm and 8.1 kg. Allow 78 W of heat loss, 44 m3/h of air flow and a sound level of 50 dB(A) in cabinet and room planning.
Braking, filters and options
Dynamic braking: chopper built in as standard (frames R1 to R4); resistor JBR-03 (80 ohm, 40 kJ, 0.14 kW continuous); minimum 78 ohm at 2.2 kW. Order +E202 for a C2 filter, +E200 for C3 or +E201 for IT networks; the standard drive meets C4 on grounded networks. The catalogue’s sine filter for this size is B84143V0006R229, rated 5.3 A, for step-up and long-cable duty.
Standard I/O is 6 digital inputs, 2 DIO, 2 analog inputs, 2 analog outputs and 3 relay outputs, plus STO and the RS485 link. Three option slots take fieldbus adapters, I/O extensions, feedback modules and a safety functions module.
Related ABB products: ABB ACQ580-01-05A7-4 Water Drive 2.2 kW 5.6 A, ABB ACS580-01-05A7-4 AC Drive 2.2 kW 5.6 A, ABB ACS380-040N-05A6-4 Machinery Drive 2.2 kW 5.6 A, ABB ACS150-03E-05A6-4 Micro Drive 2.2 kW 5.6 A, ABB ACQ580-01-046A-4 Water Drive 22 kW 45 A and ABB ACS480-04-05A7-4 General Purpose Drive 2.2 kW 5.6 A.
Documentation and ordering
The ratings, dimensions, brake and filter data were read from the ACS880 single drives catalogue 3AUA0000098111, which is linked, and ABB’s page for the ACS880-01-05A6-3. Seven Star LLC supplies the ACS880-01-05A6-3 on request from Muscat; availability and lead time are stated in the quotation. Confirm before ordering: plus codes, motor current, enclosure class, filters, brake resistor and derating for temperature and altitude. More sizes sit in AC drives, and the ABB ACS580 page covers the general purpose family.
Datasheets & Documents
- Catalog ABB ACS880 single drives catalog (3AUA0000098111) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
Related products
Frequently Asked Questions
ABB lists 5.6 A nominal (2.2 kW), 5.3 A (2.2 kW) for light overload, 4 A (1.5 kW) for heavy duty and 6.8 A maximum output current.
It is frame R1: 409 mm high with cable entry box, 155 mm wide, 226 mm deep and 7 kg; the IP55 version is 450 x 162 x 292 mm and 8.1 kg.
The brake chopper is built in as standard (frames R1 to R4); the catalogue lists JBR-03 (80 ohm) and a minimum resistance of 78 ohm.
The catalogue gives 78 W of heat dissipation, 44 m3/h of air flow and 50 dB(A) noise.
The catalogue lists +E202 for C2, +E200 for C3 and +E201 for ungrounded networks; category C4 is standard on 380 to 500 V ACS880-01 drives.