The ACS580-04-725A-4 is an ABB ACS580-04 drive module for 380 to 415 V supplies, supplied in IP00 for installation in a cabinet. It delivers 725 A continuously (400 kW typical motor power) in frame R11. Engineers pick this size for main drives built into switchrooms and heavy-duty cabinets at 400 to 500 kW. The module already includes Safe Torque Off, the control panel with USB and its mounting platform.

Technical specifications

Parameter Specification
Type designation ACS580-04-725A-4
Series ACS580-04, drive module (IP00, for cabinet installation)
Supply voltage 3-phase 380 to 415 V (400 V table)
Nominal rating 400 kW, 725 A
Light-overload rating 715 A = 400 kW
Heavy-duty rating 566 A = 315 kW; 150% for 1 min per 10 min
Peak current Imax 1020 A
Frame size R11
Module height, width, depth 1662 mm, 350 mm, 529 mm
Module mass 200 kg
480 V light-overload 705 A, 600 Hp
480 V heavy duty 566 A, 450 Hp
Cooling air flow 1200 m3/h (707 ft3/min)
Maximum noise level 72 dBA
Input fuses See hardware manual 3AXD50000015497
Safety Safe Torque Off (SIL 3)

Sizing the ACS580-04-725A-4 for the motor

From the ratings table: nominal 725 A / 400 kW, light overload 715 A / 400 kW, heavy duty 566 A / 315 kW, Imax 1020 A. Overload capability: 110% in light-overload use, 150% in heavy duty, each for 1 minute per 10 minutes at 40 degrees C. At 440 to 480 V the ratings become 705 A / 600 Hp and 566 A / 450 Hp. Pumps and fans fit the light-overload figures, conveyors and mixers the heavy-duty ones.

Thermal data: 8700 W, 1200 m3/h, 72 dBA. Fuse sizes and types for the R10 and R11 modules are given in the ACS580 hardware manual 3AXD50000015497, not in the catalogue, so check them there. Ratings apply to the IP00 or IP20 enclosed module up to +40 degrees C.

Allow a cabinet space of 350 mm width, 1662 mm height and 529 mm depth for the module (200 kg). Two construction options exist: +B051 for IP20 shrouds and +H370 for full-size input terminals.

Filters, fieldbus and options

In the code ACS580-04-725A-4 the 4 marks the drive module, the current figure is 725 A and the final 4 is the 380 to 480 V class. ABB’s option list includes +K458 for FSCA-01 Modbus RTU, +K462 for FCNA-01 ControlNet, +K469 for FECA-01 EtherCAT. EMC: C2 for wall-mounted drives and cabinets up to frame R9, C3 for modules and the R10 to R11 cabinets. Braking on frame R11 requires an external brake chopper and resistor.

Related ABB products: ABB ACH580-04-585A-4 HVAC Drive Module 315 kW 585 A, ABB ACS580-01-07A3-4 AC Drive 3 kW 7.2 A, ABB ACS580-01-026A-4 AC Drive 11 kW 25 A, ABB ACS580-01-062A-4 AC Drive 30 kW 62 A, ABB ACS580-01-073A-4 AC Drive 37 kW 73 A and ABB ACS550-01-087A-4 AC Drive 45 kW 87 A.

Documents and quotation

The ratings, dimensions, fuses and heat loss were read from ABB’s ACS580 catalogue 3AUA0000145061 (revision G, linked) and ABB’s page for the ACS580-04-725A-4. To request the ACS580-04-725A-4, send Seven Star LLC the motor data and supply details; availability is given in the quotation. Please confirm type code, options, motor data and ambient conditions before ordering; the catalogue revision may be newer than the linked one. For the ACS580-04-725A-4, tell us the application, the cable lengths, the ambient temperature and the installation altitude so derating can be checked before the offer is issued. More sizes sit in AC drives, and the ABB ACS580 page introduces the family.

Datasheets & Documents
  • PDF Catalog ABB general purpose drives ACS580 catalog 3AUA0000145061 (Rev G) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.

ABB company profile

Formed 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50%
ASEA Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators
Brown, Boveri & Cie Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri
Headquarters Zurich, Switzerland; ABB Ltd became the group holding company in 1999
Ownership Public company listed on SIX Swiss Exchange and Nasdaq Stockholm
Brands in the group Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers
Product families Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots

Milestones

  • 1883: ASEA is founded in Västerås, Sweden.
  • 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
  • 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
  • 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
  • 2011 and 2017: Baldor Electric and B&R join ABB.
  • 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.

Choosing an ABB drive

ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.

Where ABB products are used

In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.

ABB products we list

Family Examples
AC drives ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module
Breakers, motor control and protection SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay
Flow measurement ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500
Pressure, temperature and level 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge
Analysers Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210
Control systems and actuators AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000

Ordering ABB products: what we need

Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.

Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.

FAQ

Questions about the ABB ACS580-04-725A-4 Drive Module 400 kW 725 A

Answers from our engineering team on installation, compatibility and integration.

01What are the duty ratings of the ACS580-04-725A-4?
ABB lists 725 A nominal (400 kW), 715 A (400 kW) light overload, 566 A (315 kW) heavy duty and 1020 A maximum output current.
02What construction is the ACS580-04-725A-4?
It is the ACS580-04 drive module in frame R11, delivered as an IP00 chassis for cabinet installation.
03How much heat does the ACS580-04-725A-4 produce?
The catalogue gives 8700 W of heat dissipation, 1200 m3/h of air flow and 72 dBA of noise.
04Does the ACS580-04-725A-4 include Safe Torque Off?
Yes. Safe Torque Off (SIL 3) is part of the standard drive according to the ACS580 catalogue.
05Which fieldbus options fit the ACS580-04-725A-4?
The catalogue lists FDNA-01, FPBA-01, FCAN-01, FSCA-01, FCNA-01, FECA-01, FEPL-02, FENA-11 and FENA-21 adapters; Modbus RTU is built in.