- Automation & ControlView all 2,894 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: ABB
ABB ACS580-01-025A-2 5.5 kW Wall-Mounted Drive
Description
ABB ACS580-01-025A-2 wall-mounted drive for 5.5 kW motors
The ABB ACS580-01-025A-2 is a wall-mounted low-voltage AC drive from the ABB general purpose drives family, ACS580. It belongs to frame size R2 and is rated for a 230 V class supply (3-phase 200 to 240 V), with a nominal output current of 24.5 A and a typical motor power of 5.5 kW. This is a 230 V class drive for 3-phase supplies in the range 200 to 240 V. At 24.5 A and 5.5 kW it serves low-voltage pumps and fans on 230 V networks, for example on imported machinery or in installations with a 230 V delta supply.
This page describes the ACS580-01-025A-2 so that you can compare it with neighbouring ratings, prepare the electrical design and send a complete enquiry. The data comes from the ABB ACS580 catalog; the hardware manual of the drive remains the reference for final installation details.
Decoding the ACS580-01-025A-2 type designation
ABB builds the ACS580 type code from a short series of fields. For this drive the code reads as follows.
| Field | Value in ACS580-01-025A-2 | Meaning |
|---|---|---|
| Product series | ACS580 | General purpose drive platform |
| Type and construction | 01 | Standard (non-regenerative) drive, wall-mounted construction |
| Rating | 025A | Current class label used in the ordering code; the nominal current in the ratings table is 24.5 A |
| Voltage | 2 | 3-phase 230 V class (200 to 240 V) |
| Options | + codes | Added after the base code, for example +B056 for IP55 or +F278 for an integrated main switch |
ACS580-01-025A-2 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | ABB / ACS580-01-025A-2 |
| Product family | ACS580-01 wall-mounted general purpose drive, frame R2 |
| Supply voltage | 3-phase 200 to 240 V (+10 % / −15 %), 47 to 63 Hz |
| Nominal output current / motor power (no overload) | 24.5 A / 5.5 kW |
| Light-duty rating | 24.2 A for 5.5 kW (110 % overload for 1 minute in 10 minutes at 40 °C) |
| Heavy-duty rating | 16.7 A for 4 kW (150 % overload for 1 minute in 10 minutes at 40 °C) |
| Maximum output current | 32.7 A, available for 2 seconds at start |
| Heat loss, cooling air, noise | 253 W typical; 101 m³/h (59 ft³/min); 64 dBA at full fan speed |
| Recommended input fuse | 40 A gG (IEC) |
| Motor control | Scalar and vector control; induction, permanent magnet, synchronous reluctance and PM-assisted SynRM motors |
| Degree of protection | IP21 (UL Type 1) as standard; IP55 (UL Type 12) as option |
| Ambient temperature | –15 to +55 °C, with derating from +40 °C; no frost allowed |
| Altitude | Full current 0 to 1000 m; reduced by 1 % per 100 m above 1000 m, up to 4000 m |
| EMC and efficiency | EMC category C2 as standard; efficiency class IE2 (IEC 61800-9-2) |
| Functional safety | Safe Torque Off, SIL 3 / PL e |
| Communication | Modbus RTU embedded (EIA-485); fieldbus adapters as options |
| Control I/O (standard) | 2 analog inputs, 2 analog outputs, 6 digital inputs, 3 relay outputs, 24 V DC auxiliary output up to 250 mA |
Ratings and overload behaviour of the ACS580-01-025A-2
The ACS580 catalog defines three current values for each drive. The nominal rating of 24.5 A is available continuously without overload at 40 °C. The light-duty rating of 24.2 A allows 110 % current for one minute in every ten, which fits pumps and fans whose load rises slowly. The heavy-duty rating of 16.7 A allows 150 % for one minute in every ten, for machines such as conveyors and mixers with a higher starting torque. The maximum output current is 32.7 A and may be drawn for 2 seconds at start.
The fuse recommendation is 40 A gG. Remember that a 230 V drive cannot be used on a 400 V network, so check the supply voltage on the plant drawings before ordering.
How the ACS580 controls the motor
Inside the ACS580 the incoming AC is converted to DC, smoothed by a choke that also limits harmonic current, and inverted again to feed the motor with variable voltage and frequency. Operators choose between scalar mode, which is simple and robust for centrifugal loads, and vector mode, which gives faster torque response and supports permanent magnet and synchronous reluctance machines.
Built-in software tools help on site: a startup assistant for first power-up, a diagnostic assistant that suggests remedies, an energy optimizer that reduces flux at part load, a process PID controller and automatic parameter backup. Protection covers overcurrent, DC over- and undervoltage, overtemperature, phase loss and earth leakage, and Safe Torque Off to SIL 3 / PL e is part of the standard drive.
The assistant control panel is delivered with every ACS580 drive, and the Bluetooth panel and PC tools are available for commissioning and backup.
Where ACS580-01-025A-2 fits among ACS580 ratings
The ACS580-01 range covers wall-mounted drives from 0.75 kW up to 355 kW on 380 to 480 V supplies, and the same family has drive modules (ACS580-04) and cabinet-built versions (ACS580-07) for higher powers. In the 400 V list the ACS580-01-025A-2 sits between ACS580-01-018A-2 and ACS580-01-032A-2; if the motor current is close to a boundary, check the neighbouring type before ordering. Related ABB drive families such as the ACS355 machinery drive and the ACH580 HVAC drive are different products with their own ordering codes; the ACS580 is the choice when one platform is wanted for pumps, fans, conveyors and general machinery.
Frame R2 ratings related to ACS580-01-025A-2
| Type designation | Frame | Nominal power (kW) | Nominal current (A) | Light-duty current (A) | Heavy-duty current (A) |
|---|---|---|---|---|---|
| ACS580-01-025A-2 | R2 | 5.5 | 24.5 | 24.2 | 16.7 |
| ACS580-01-032A-2 | R2 | 7.5 | 31.2 | 30.8 | 24.2 |
Selection and ordering checklist
- Confirm the supply: the ACS580-01-025A-2 is for 3-phase 200 to 240 V; the suffix -4 is 400 V class and -2 is 230 V class.
- Check the motor nameplate current against the 24.5 A nominal, 24.2 A light-duty or 16.7 A heavy-duty current, depending on the load type.
- Choose enclosure: IP21 (UL Type 1) is standard; add +B056 for IP55 (UL Type 12). Frames R1 to R3 are also listed in an IP66 (Type 4X) version.
- Frames R1 to R5 in IP55 can be ordered with an integrated main switch (+F278), an EMC C1 filter (+E223) or both (+F316).
- Check cable length: the recommended maximum motor cable is 200 m, and longer runs call for output filters.
- Select a communication adapter and any I/O extension if the standard I/O and Modbus RTU are not enough.
- Confirm the plus codes and the current class against the ABB ordering table before sending the order.
Installing and commissioning ACS580-01-025A-2
Frame R2 dimensions are shown in the table. The IP21 unit is 473 mm high (with the gland box), 125 mm wide and 229 mm deep and weighs 6.6 kg. The IP55 unit is 503 mm high, 128 mm wide and 239 mm deep and weighs 6.8 kg; with the main switch or C1 filter option the height becomes 503 mm and the weight 7.4 kg.
| Version | Height (mm) | Width (mm) | Depth (mm) | Weight (kg) |
|---|---|---|---|---|
| IP21 (UL Type 1) | 473 | 125 | 229 | 6.6 |
| IP55 (UL Type 12) | 503 | 128 | 239 | 6.8 |
Provide 101 m³/h of cooling air and allow for 253 W of heat dissipation in cabinet design. Feed the drive through 40 A gG fuses as recommended in the catalog, and follow the hardware manual for cable sizes and earthing. On first power-up the startup assistant on the control panel walks through motor data and macros; it is good practice to store a parameter backup on the panel after commissioning so that a replacement drive can be loaded quickly. Keep the exact type designation and plus codes from the nameplate with your spares record.
Typical applications of ACS580-01-025A-2 in Oman and the GCC
In Oman and the GCC small drives like this one are found in air-handling units on hotel and office roofs, in utility pump skids at desalination and water-treatment sites, and on conveyors and mixers in food, packaging and light-industrial plants. The ambient in a Muscat technical room or a rooftop plant box can run well above 40 °C in summer, so the derating rule matters: the catalog gives full current up to 40 °C and lets the drive operate up to the higher limit with derating. Fine dust and salty humid air are the other everyday stresses, which is why an IP55 version is often preferred for wall mounting outside a clean electrical room.
Information to send with an RFQ
For a correct offer, please send the full type designation including plus codes, the supply voltage and frequency, the motor power and rated current, the type of load (fan, pump, conveyor or other), the ambient temperature and altitude, the required enclosure class and any filter, switch or fieldbus option. A photograph of the nameplate of the drive being replaced is the fastest way to confirm a like-for-like match with the ACS580-01-025A-2.
Documents and quotation
The ABB ACS580 catalog is attached on this page. It includes the ratings, cooling data, dimensions, options and ordering codes used in this description, so please check your final selection of the ACS580-01-025A-2 against it.
Seven Star LLC supplies ABB drives in Oman and the GCC. Send the part number and your duty details and we will return a quotation with delivery information.
Other Models in the Abb Acs580 01 Wall Range
Seven Star LLC supplies models from the Abb Acs580 01 Wall range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ABB ACS580-01-025A-2 5.5 kW Wall-Mounted Drive | AC Drives | You are viewing this model |
| ABB ACS580-01-076A-2 18.5 kW Wall-Mounted Drive | AC Drives | View details |
Datasheets & Documents
- Catalog ABB ACS580-01-025A-2 Catalog Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB ACS580-01-025A-2 5.5 kW Wall-Mounted Drive
Answers from our engineering team on installation, compatibility and integration.
01Can ACS580-01-025A-2 run from a 400 V supply?
No. This type designation ends in -2, meaning a 3-phase 200 to 240 V supply. Drives for 380 to 480 V networks carry the suffix -4, for instance ACS580-01-026A-4, and the two families are not interchangeable.
02What enclosure does ACS580-01-025A-2 have as standard?
The standard ACS580-01 is IP21 (UL Type 1). An IP55 (UL Type 12) version is available with the +B056 code, and an IP66 (Type 4X) version is listed for frames R1 to R3. The IP55 drive is designed for dusty or humid locations.
03Does ACS580-01-025A-2 include Safe Torque Off?
Yes. Safe Torque Off is built in as standard on ACS580 drives and is rated SIL 3 / PL e according to the standards listed in the catalog, so no extra module is required for the basic safety function.
04What control interface does ACS580-01-025A-2 provide as standard?
The standard I/O has two analog inputs, two analog outputs, six digital inputs, three relay outputs and a 24 V DC auxiliary output up to 250 mA. Modbus RTU is embedded, and further fieldbus adapters can be added as options.
05What airflow and fuse does ACS580-01-025A-2 need?
The catalog lists 101 m³/h of cooling air, 253 W typical heat loss and a recommended 40 A gG input fuse.


















Reviews