Brand:

Hydac EDS 4448-0100-1-PP-000 Electronic Pressure Switch 100 bar

Description

If a machine drawing calls for a 100 bar programmable switch with an M12 connector, the Hydac EDS 4448-0100-1-PP-000 is the part that fits. The G1/4 A male port, one PNP output and 5-pole M12x1 plug are shared by the whole 4448 group; the range of 0 to 100 bar, the overload of 200 bar and the burst rating of 500 bar are what identify this variant. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Why the 100 bar range is popular

One hundred bar is a common value for hydraulic return and pilot circuits, for water-injection headers and for compressed-gas skids. At this range the step for the set point is 0.2 bar, and the usable window runs from 5 to 100 percent of range for the switch point, so a trip at 8 bar or 95 bar is reachable. The one-percent accuracy of EDS 4448-0100-1-PP-000 corresponds to 1 bar at full scale.

One practical advantage of the 100 bar range is that it matches the gauge scale most plants already stock. When a mechanical 0 to 100 bar gauge sits next to this switch, the two can be compared at three points during commissioning. A mechanical gauge also gives the technician a visual cross-check of the 200 bar overload reserve whenever a spike is suspected, because the gauge pointer and the switch can be watched during the same test.

Feature list

  • Range 0 to 100 bar, overload 200 bar, burst 500 bar.
  • Step 0.2 bar; delay 8 to 2000 ms in 8 ms increments.
  • Output rated 1.2 A, PNP, N/O or N/C by programming.
  • Weight about 145 g; hex 27 mm; seal profile ring to DIN 3869.
  • Ambient range -25 to 85 degC; fluid range -25 to 100 degC with FKM.
  • Shock 100 g for 1 ms, vibration 20 g.

Specification table, EDS 4448-0100-1-PP-000

Parameter Value
Model code EDS 4448-0100-1-PP-000
Material number (catalog) 920090
Setting range 0 to 100 bar
Overload pressure 200 bar
Burst pressure 500 bar
Process connection G1/4 A ISO 1179-2, male
Tightening torque 20 N·m recommended
Wetted parts Stainless steel connection; FKM seal
Switching output 1 PNP transistor output, programmable, N/O or N/C
Switching current 1.2 A maximum with one output
Switch-point increment 0.2 bar
Switch point / hysteresis window 5 to 100 percent / 1 to 96 percent of range
Delay times 8 to 2000 ms in 8 ms steps (HPG 3000)
Response time 8 ms
Accuracy 1 percent FS maximum; 0.5 percent typical
Temperature coefficient 0.02 percent FS per degC typical, 0.03 maximum
Repeatability 0.1 percent FS maximum
Long-term drift 0.3 percent FS per year typical
Electrical connection M12x1 male, 5-pole
Pins 1 +UB, 2 not connected, 3 0 V, 4 output 1, 5 not connected
Supply voltage 8 to 32 V DC, ripple 5 percent or less
Current consumption 25 mA inactive; 2.025 A total maximum
Switching cycles more than 100 million
Compensated temperature -25 to 85 degC
Storage temperature -40 to 100 degC
Protection class IP 67
Vibration / shock 20 g (10 to 500 Hz) / 100 g (1 ms)
Weight about 145 g
Approvals / EMC CE (EN 61000-6-1/2/3/4); cULus E318391

Typical uses

Examples: charge pressure supervision on injection moulding units, pump discharge pressure on cooling-water skids, brake release and clamp monitoring on rotating equipment. For Gulf sites, the stainless connection and FKM seal fit hydraulic oils, many lubricants and compressed air. For hazardous zones use another approved family; EDS 4448-0100-1-PP-000 carries CE and cULus markings only.

How EDS 4448-0100-1-PP-000 differs from siblings

The 0040 unit has a 40 bar range and 0.1 bar step; this unit extends that to 100 bar and 0.2 bar. The 0250 version moves up to 250 bar with 500 bar overload and 1000 bar burst. Electrical, mechanical and temperature data are common to all four listed variants, so the choice is purely about pressure.

Choosing correctly

Pick a range so that the normal operating pressure lies below about 70 bar, leaving the upper part of the range for peaks. If the switch point is below 5 bar, the 0040 range gives better resolution than EDS 4448-0100-1-PP-000.

Installation

Fit into a G1/4 port with a profile seal, tighten to 20 N·m, plug in the M12 connector, and power from 8 to 32 V DC. Program the points with the HPG 3000 and check the output direction while a hand pump raises the pressure on EDS 4448-0100-1-PP-000.

Maintenance

Keep the plug seal clean to preserve IP 67. The cell has a long-term drift of 0.3 percent of full scale per year typical, so an annual comparison with a reference gauge is a sensible interval.

Documentation: file the programmed set points with the loop sheet and note the catalog material number 920090 for reorders. The accessory list should include the M12 five-pole mating connector and, if a field programmer is not already available, the HPG 3000 unit. Both are separate items from the switch itself.

What to Include in Your Hydac EDS 4448-0100-1-PP-000 Enquiry

An accurate quotation for the Hydac EDS 4448-0100-1-PP-000 depends on a few details. Please share the complete part number, any suffix codes for options or approvals, the operating conditions at the installation point, and whether certificates of conformity or test reports must ship with the goods. It also helps to know whether the unit is for planned maintenance, a shutdown or an urgent breakdown, because that decides how it is sourced and shipped. With this information our team can check compatibility with your existing pressure switches and reply with availability and a realistic delivery estimate.

Frequently asked questions about EDS 4448-0100-1-PP-000

Which burst pressure applies to EDS 4448-0100-1-PP-000? 500 bar, with an overload pressure of 200 bar.

What is the step size for the switch point? 0.2 bar according to the catalog record for the 100 bar range.

Is a programming unit supplied? No. The HPG 3000 is ordered separately; the datasheet lists it as a portable programming unit with part number 909422.

What are the pin functions? Pin 1 is +UB, pin 3 is 0 V and pin 4 is output 1. Pins 2 and 5 are not connected on this single-output model.

How do I enquire? Send an RFQ to Seven Star LLC quoting EDS 4448-0100-1-PP-000 and the quantity.

Documents and quotation

The datasheet for EDS 4448-0100-1-PP-000 is provided on this page. For a quotation send an RFQ listing EDS 4448-0100-1-PP-000, quantity and delivery location.

Other Models in the EDS 4400 Range

Seven Star LLC supplies models from the EDS 4400 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Hydac EDS 4448-0250-1-PP-000 Programmable Pressure Switch 250 barPressure SwitchesView details
Hydac EDS 4448-0100-1-PP-000 Electronic Pressure Switch 100 barPressure SwitchesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Hydac EDS 4448-0100-1-PP-000 Electronic Pressure Switch 100 bar Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.

Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.

HYDAC at a glance

Established 1963, Sulzbach, Saarland, Germany
Name From "hydraulic accumulator", the first product line
Ownership Family-owned; around 50 international subsidiaries
Product families Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring

HYDAC products we list

Family Models Typical use
Pressure filters DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND Protect servo and proportional valves downstream of the pump
Low-pressure, return and suction filters LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX Return line, lube oil, turbine oil and suction filtration
Breathers and indicators BF, ELF, BDE dryer, VD clogging indicator Keep dust and moisture out of the tank and show when an element needs changing
Accumulators SB330 bladder accumulator Energy storage, pulsation damping and emergency actuation
Pressure transmitters HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP Pressure measurement in hydraulic and process systems
Pressure, temperature and level switches EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 Local display plus switching outputs for alarms and interlocks

Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.

Where HYDAC products are used

In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.

Ordering HYDAC products: what we need

Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.

Facts checked against HYDAC company information, October 2026.

FAQ

Questions about the Hydac EDS 4448-0100-1-PP-000 Electronic Pressure

Answers from our engineering team on installation, compatibility and integration.

01Which burst pressure applies to EDS 4448-0100-1-PP-000?
500 bar, with an overload pressure of 200 bar.
02What is the step size for the switch point?
0.2 bar according to the catalog record for the 100 bar range.
03Is a programming unit supplied?
No. The HPG 3000 is ordered separately; the datasheet lists it as a portable programming unit with part number 909422.
04What are the pin functions?
Pin 1 is +UB, pin 3 is 0 V and pin 4 is output 1. Pins 2 and 5 are not connected on this single-output model.
05How do I enquire?
Send an RFQ to Seven Star LLC quoting EDS 4448-0100-1-PP-000 and the quantity.