Brand:

Hydac EDS 4479-3000-2P-DS-000 Two-Output Flameproof Pressure Switch

Description

EDS 4479-3000-2P-DS-000 is the two-output member of the flameproof EDS 4400 line and it is the version that serves a pre-alarm and a trip with one instrument. Both outputs are PNP, each rated 1 A, and both are programmable through the HPG 3000. The process port is an SAE-6 male thread and the catalog description shows a 5 m cable. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Why two outputs help

On a 3000 psi hydraulic unit it is common to want a warning at one pressure and a shutdown at another. With a single-output switch that means two devices, two process taps and two approved cables. EDS 4479-3000-2P-DS-000 puts both contacts on one tap: the cores are red (+UB), white (output 1), brown (output 2), black (0 V) and green (programming). The load limit per contact is 1 A, and the supply current can reach 2.025 A when both outputs are loaded.

Wiring discipline matters with two loads on one cable. Keep the white and brown output cores in separate terminal blocks from the programming line, use diodes across inductive loads such as relay coils, and size the supply for 2.025 A at worst case. The programming unit connects only temporarily. Because the catalog quotes a 5 m cable, plan the junction box within that length or terminate the lead in a certified enclosure close to the switch.

Features

  • Two PNP outputs, 1 A each, independent set points and hysteresis.
  • SAE-6 male port with O-ring face, 20 N·m torque.
  • Range 0 to 3000 psi, overload 7250 psi, burst 14500 psi.
  • Increment 5 psi, response time 8 ms.
  • Operating temperature -4 to 176 degF at T5 and -4 to 140 degF at T6.
  • Triple approval for mining, gas and dust.

Specification table

Parameter Value
Model code EDS 4479-3000-2P-DS-000
Material number (catalog) 924664
Setting range 0 to 3000 psi
Overload pressure 7250 psi
Burst pressure 14500 psi
Cell type Sealed gauge (S)
Process connection SAE-6 male, 9/16-18 UNF 2A
Tightening torque 20 N·m (15 lb-ft)
Switching outputs 2 PNP, programmable
Output load max. 1 A each
Switch-point increment 5 psi
Switch point / hysteresis window 5 to 100 percent / 1 to 96 percent of range
Switching delay 8 to 2000 ms via HPG 3000 programming unit
Response time 8 ms
Accuracy 1 percent FS maximum (0.5 percent typical)
Repeatability 0.1 percent FS maximum
Supply voltage 12 to 30 V DC, ripple 5 percent or less
Current consumption 25 mA plus switching currents, 2.025 A total maximum
Electrical connection 1/2-14 NPT conduit, flying leads
Core assignment red +UB, white switch output 1, brown switch output 2, black 0 V, green SDA (programming)
Switching cycles more than 100 million
Compensated temperature T5 / T130: -13 to 176 degF; T6 / T110: -13 to 140 degF
Storage temperature -40 to 212 degF
Protection IP 69K (sealed gauge)
Vibration 20 g, 10 to 500 Hz
Weight 0.661 lb (about 300 g)
Approvals ATEX KEMA 10ATEX100 X; CSA MC 224264; IECEx KEM 10.0053X

Where it is used

It suits hydraulic blocks with an SAE-6 gauge port in mines, clamping circuits in classified workshops, and skid-mounted hydraulic power units where an operator panel needs both a low-pressure warning and a trip signal from EDS 4479-3000-2P-DS-000.

How EDS 4479-3000-2P-DS-000 differs from the 1P versions

EDS 44F9-3000-1P-DS-000 has the same range, overload and burst, but only one output, an NPT female port and a 40 N·m torque value. The present part has a second output, SAE-6 male and 20 N·m. The operating temperature minimum rises to -4 degF in the catalog record of the 4479 unit, versus -40 degF in the 44F9 record.

Selection

Check that the manifold has an SAE-6 port and that the controller has two PNP inputs. If only one contact is needed, the 1P version is simpler to wire. For EDS 4479-3000-2P-DS-000, plan a supply capable of 2 A when both outputs switch full load.

Installation and set-up

Fit with a clean O-ring, tighten to 20 N·m, wire both outputs to their loads and use the HPG 3000 to enter the two set points. Choose hysteresis so that pump cycling at the lower point does not chatter the output of EDS 4479-3000-2P-DS-000.

Maintenance

Annual verification of both switching points with a hand pump is adequate. Replace the O-ring on every removal. The enclosure must not be opened in the hazardous area.

Documentation tip: log both programmed set points, the hysteresis values and the switching direction for each output on the maintenance sheet. If one output is later reprogrammed from N/O to N/C, the sheet shows what changed. The same sheet should carry the catalog material number 924664 so that a replacement can be matched exactly, including the SAE-6 port and the second output.

Selection Notes for the Hydac EDS 4479-3000-2P-DS-000

When comparing the Hydac EDS 4479-3000-2P-DS-000 with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the Hydac pressure switches range and confirm the correct order code before you commit.

Frequently asked questions about EDS 4479-3000-2P-DS-000

What does 2P mean in EDS 4479-3000-2P-DS-000? Two programmable PNP transistor outputs. Each can be set independently with the HPG 3000 programming unit.

What is the current limit per output? 1 A each with two outputs in use, while total consumption is up to 2.025 A.

Which process connection is fitted? SAE-6 male, 9/16-18 UNF 2A, tightened to 20 N·m.

How long is the cable? The catalog description of this material number shows 5 m.

How can I order EDS 4479-3000-2P-DS-000? Send an RFQ with the part number and quantity to Seven Star LLC.

Documents and quotation

The datasheet for EDS 4479-3000-2P-DS-000 is provided on this page. Send an RFQ with EDS 4479-3000-2P-DS-000, quantity and the delivery site, and we reply with availability.

Datasheets & Documents
  • PDF Datasheet Hydac EDS 4479-3000-2P-DS-000 Two-Output Flameproof Pressure Switch Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.

Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.

HYDAC at a glance

Established 1963, Sulzbach, Saarland, Germany
Name From "hydraulic accumulator", the first product line
Ownership Family-owned; around 50 international subsidiaries
Product families Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring

HYDAC products we list

Family Models Typical use
Pressure filters DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND Protect servo and proportional valves downstream of the pump
Low-pressure, return and suction filters LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX Return line, lube oil, turbine oil and suction filtration
Breathers and indicators BF, ELF, BDE dryer, VD clogging indicator Keep dust and moisture out of the tank and show when an element needs changing
Accumulators SB330 bladder accumulator Energy storage, pulsation damping and emergency actuation
Pressure transmitters HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP Pressure measurement in hydraulic and process systems
Pressure, temperature and level switches EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 Local display plus switching outputs for alarms and interlocks

Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.

Where HYDAC products are used

In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.

Ordering HYDAC products: what we need

Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.

Facts checked against HYDAC company information, October 2026.

FAQ

Questions about the Hydac EDS 4479-3000-2P-DS-000 Two-Output Flameproof

Answers from our engineering team on installation, compatibility and integration.

01What does 2P mean in EDS 4479-3000-2P-DS-000?
Two programmable PNP transistor outputs. Each can be set independently with the HPG 3000 programming unit.
02What is the current limit per output?
1 A each with two outputs in use, while total consumption is up to 2.025 A.
03Which process connection is fitted?
SAE-6 male, 9/16-18 UNF 2A, tightened to 20 N·m.
04How long is the cable?
The catalog description of this material number shows 5 m.
05How can I order EDS 4479-3000-2P-DS-000?
Send an RFQ with the part number and quantity to Seven Star LLC.