Brand:

Honeywell STG830 Gauge Pressure Transmitter, 50 psi

Description

Honeywell STG830 overview

The Honeywell STG830 is a SmartLine ST 800 gauge pressure transmitter that combines a piezoresistive sensor with on-chip temperature compensation. It is the low-range model of the gauge family, covering -14.7 to 50 psi (-1.01 to 3.44 bar), so it reads both vacuum and low positive pressure. It is fully tested for compatibility with Experion PKS, so it is a frequent replacement or expansion item for plants that run Honeywell control systems.

The Honeywell STG830 suits tank blanketing, low-pressure fuel gas, burner and flare header measurements and vacuum duties where the range must be tight. Seven Star LLC lists the STG830 for plants in Oman and the GCC that need the exact model number to match an existing instrument index or spare parts list.

Key features of the STG830

  • Piezoresistive sensing with on-chip temperature compensation, giving high accuracy and stability across the rated range.
  • 4 to 20 mA output with Honeywell DE, HART version 7 or FOUNDATION Fieldbus, all with polarity-insensitive wiring.
  • Response time of 80 ms for DE and HART and 150 ms for FOUNDATION Fieldbus (host dependent).
  • Rangeability up to 200 to 1 and stability up to 0.01% of URL per year for 15 years across the family.
  • Standard LCD or advanced graphics LCD, three-button local configuration, and modular electronics, display and meter body.
  • Plugged impulse line detection option, dual or triple calibration for HART and Fieldbus, and NAMUR NE-107 extended diagnostics.
  • Integral dual seal design, listed compliance with SIL 2/3 requirements, and an optional extra 15-year warranty.

The STG830 shares its electronics, displays and diagnostics with the other STG800 models, so the model number mainly decides the range, the working pressure and the overpressure rating.

STG830 technical specifications

The table below summarises the values published by Honeywell for the STG830. Where a value depends on the communication protocol, the housing or an ordering option, the entry says so, and the full model selection guide in the datasheet remains the reference for exact option codes.

Parameter Value
Model STG830
Measurement Gauge pressure, piezoresistive sensor
Upper range limit (URL) 50 psi (3.44 bar)
Lower range limit (LRL) -14.7 psi (-1.01 bar)
Maximum turndown ratio 100:1
Reference accuracy, % of span 0.0375 standard, 0.025 optional
Family stability Up to 0.01% of URL per year for 15 years
Response time 80 ms (DE and HART); 150 ms (FOUNDATION Fieldbus, host dependent)
Output and protocols Two-wire 4 to 20 mA with DE or HART 7; FOUNDATION Fieldbus ITK 6.0.1 compliant
Supply voltage HART: 10.8 to 42.4 VDC at terminals (intrinsically safe versions limited to 30 VDC); DE: 15 to 49.3 VDC; Fieldbus: 9.0 to 32.0 VDC
Maximum allowable working pressure 50 psi (3.5 bar)
Overpressure 75 psi (5.25 bar)
Rated ambient temperature -40 to 85 °C (-40 to 185 °F)
Rated meter body temperature -40 to 110 °C (-40 to 230 °F)
Fill fluid Silicone 200, CTFE, NEOBEE M-20 or Silicone 704
Process connection 1/2 inch NPT female, DIN 19213 (standard)
Housing Low-copper aluminium, Type 4X, IP66 and IP67; all-stainless-steel housing optional
Net weight 8.3 lb (3.8 kg)

Honeywell gives a total performance example for this model: the STG830 at 10 psi reaches 0.059% of span for standard accuracy, 5 to 1 turndown and a temperature shift of up to 50 °F. Total performance is the square root of the sum of squares of accuracy and temperature effect. Calibration verification is recommended every four years. The no-burst pressure is 3 times MAWP for ratings up to 2,000 psi and 2.5 times MAWP plus 1,000 psi above that.

Typical applications in Oman and the GCC

A gauge pressure transmitter reports line or vessel pressure relative to atmosphere. The STG830 is typically specified for the following duties.

  • Oil and gas: wellhead and separator monitoring, custody-adjacent flow measurement loops, compressor suction and discharge duties, and fuel gas skids.
  • Utilities and power: boiler drum and feedwater measurements, steam header monitoring, condenser and cooling-water loops, and fuel supply lines.
  • Water and wastewater: pump station discharge pressure, filter differential monitoring, desalination feed and reject lines, and pipeline surge surveillance.
  • Manufacturing and process plants: utility headers, compressed air and steam distribution, chemical dosing skids, and packaged equipment where a smart HART or fieldbus device is specified.

Low-pressure gas headers, blanketing systems and vacuum services are typical for this range. The STG830 housing is rated Type 4X, IP66 and IP67 and the ambient limit is -40 to 85 °C, which supports outdoor installation in hot and humid coastal sites when sunshades and gland practice are correct.

Selection and compatibility notes for the STG830

Choose the STG830 when your maximum process pressure, including expected transients, stays inside 50 psi (3.44 bar) and the maximum allowable working pressure of 50 psi (3.5 bar). Zero and span can be set anywhere within the range limits, and a lower range with high turndown gives the best accuracy at the working point.

Choose the protocol next. Honeywell lists DE, HART 7 and FOUNDATION Fieldbus for the family. Specify it in the RFQ so the correct electronics module is quoted with the STG830.

Wetted materials matter. Barrier diaphragms are listed in 316L stainless steel, Hastelloy C-276, Monel 400 and tantalum, with gold-plated options, and process heads in carbon steel, 316 stainless steel, Hastelloy C-276 or Monel 400. Carbon steel heads are zinc plated and not recommended for water service.

If you are replacing another instrument, send the existing nameplate data, calibrated range, process connection and approval marking so we can match the STG830 correctly.

Installation and commissioning

Mount the STG830 on a 2 inch pipe with the bracket or on a flat surface. Use a block valve and a vent or test connection so the transmitter can be isolated and checked in service. Keep the impulse tube short and avoid trapped condensate or gas pockets that would add static head error.

Connect the loop with up to 16 AWG wire. The terminals are polarity insensitive. Check the supply at the terminals against the voltage range for the selected protocol and remember the load resistance limit for HART and DE.

At commissioning, apply atmospheric pressure to the STG830 for a zero check, set the lower and upper range values, confirm damping and run a loop test. With the optional display and buttons, basic range, units, loop test and zero or span can be set locally. Keep the final configuration record.

Maintenance and diagnostics

The STG830 reports critical diagnostics such as electronics module faults, memory or configuration corruption and sensor communication timeout, and non-critical ones such as display failure and sensor over-temperature. These can be read through DD, DTM or FDI tools or the display.

Modular construction allows replacement of the meter body, electronics or display without disturbing the other parts, and field replacement is permitted in all electrical environments except flameproof. Record the meter body serial number of each STG830 unit on your spares list.

Routine work is a periodic zero check, inspection of housing seals and cable glands, a check of the process connection for leaks, and a documented calibration verification at your site interval.

Related products and ordering notes

Buyers of the STG830 often also order manifolds, mounting brackets or a Honeywell differential transmitter such as the STD810, STD815, STD820, STD830 or STD870 for flow and level loops. Other gauge models in the same family are the STG830, STG840 and STG870.

For temperature measurement alongside, Honeywell offers the STT850 SmartLine temperature transmitter. Send the full list in one RFQ and quote the part number STG830 for this item.

Frequently asked questions in brief

The questions below cover range, accuracy, overpressure and ordering for the STG830, and each answer follows the Honeywell specification.

Documents and quotation

A Honeywell datasheet for the STG830 is attached to this page so your engineers can check ranges, materials and approvals before ordering. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. To request a quotation, send an RFQ that states the part number STG830, the quantity, the measuring range or sensor type, the communication protocol and any display or approval requirement. We will confirm availability and lead time and reply with a written quotation.

Datasheets & Documents
  • PDF Datasheet Honeywell STG830 Gauge Pressure Transmitter, 50 psi Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell STG830 Gauge Pressure Transmitter, 50 psi

Answers from our engineering team on installation, compatibility and integration.

01What is the range of the STG830?
The STG830 has an upper range limit of 50 psi (3.44 bar) and a lower range limit of -14.7 psi (-1.01 bar).
02What accuracy does the STG830 offer?
Reference accuracy is 0.0375% of span as standard and 0.025% of span as an option, with a maximum turndown of 100 to 1.
03What are the working and overpressure limits of the STG830?
The maximum allowable working pressure is 50 psi (3.5 bar) and the overpressure limit is 75 psi (5.25 bar).
04Which protocols are available for the STG830?
Honeywell DE, HART version 7 and FOUNDATION Fieldbus, with 4 to 20 mA on DE and HART units.
05How do I order the STG830 from Seven Star LLC?
Send an RFQ with the part number STG830, quantity, protocol, display, materials and approvals. We reply with availability and a quotation.