- Automation & ControlView all 2,683 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Motor Soft Starters
- Safety Switches & Guard Locking
- CCTV & Security
- Encoders
- HMI Displays
- Servo Drives
- Pneumatic Cylinders
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Honeywell
Honeywell UDC3500 1/4 DIN Dual-Loop Digital Controller
Description
Honeywell UDC3500 dual-loop universal digital controller overview
The Honeywell UDC3500 is the most capable controller in the UDC 1/4 DIN range. It can run two loops of control or an internal cascade in a single case, accepts up to three universal analog inputs and offers two math algorithms, logic gates and a four-input digital interface. The manufacturer quotes a typical input accuracy of 0.10 percent of full scale.
The inputs can be arranged as one universal and four high level inputs, or two universal and two high level inputs, and every input is keyboard configurable. A separate cold junction compensator is provided for each thermocouple input to maximise accuracy. Accutune III tuning with fuzzy logic overshoot suppression comes as standard, and an infrared port allows configuration through the manufacturer PC software.
This page summarises the manufacturer documentation for the Honeywell UDC3500 for buyers in Oman and the GCC. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Key features of the UDC3500
The following highlights come from the manufacturer specification for the UDC3500.
- Up to three universal analog inputs, which can be set up as one universal plus four high level inputs, with typical accuracy of 0.10 percent and 16-bit resolution.
- Two independent loops or an internal cascade, with five control modes including manual cascade and automatic cascade.
- Up to seven analog and digital outputs, with up to three analog and up to five digital outputs available.
- Four digital inputs for functions such as PID set selection, setpoint selection, tuning and program run.
- Two math algorithms, five logic gates, a totalizer and combinational inputs for humidity, oxygen, carbon potential and dewpoint calculations.
- Optional enhanced setpoint programming with up to four programs of up to ten ramp and ten soak segments each, plus an optional real time clock.
- Auto/manual station with back-up PID control, so the process can keep running if a PLC loop fails.
- Healthwatch maintenance counters, alarm trip counts, and optional RS422/485 Modbus RTU or Ethernet Modbus TCP/IP communication.
UDC3500 technical specifications
The table summarises the main data for the UDC3500 from the manufacturer specification sheet.
| Parameter | Value |
|---|---|
| Model | UDC3500 |
| Format | 1/4 DIN panel mount |
| Analog inputs | Up to three universal inputs |
| Input accuracy | 0.10 percent of full scale typical |
| Resolution and sampling | 16-bit typical, six samples per second (166 ms) |
| Control loops | Two loops or internal cascade (optional) |
| Digital inputs | Four isolated dry-contact inputs (optional) |
| Outputs | Up to seven analog and digital outputs |
| Math and logic | Two math algorithms, five logic gates, totalizer |
| Setpoint programming | Up to four programs, ten ramp and ten soak segments each |
| Communications | Infrared standard; RS422/485 Modbus RTU or Ethernet Modbus TCP/IP optional |
| Display | Dual display with multi-language prompts in five languages |
| Power supply | 90 to 264 V ac, 50/60 Hz; 24 V ac/dc optional |
| Power consumption | 24 VA maximum (ac), 18 VA maximum (24 V) |
| Depth | 148 mm (5.8 inch) case |
| Weight | 1.3 kg |
| Operating temperature | 0 to 55 degC operative limits |
| Front face | NEMA4X and IP66 with screws |
Typical applications in Oman and the GCC
The UDC3500 is used where one instrument must replace several single-loop controllers or where the process needs cascade control. Typical uses in Oman and the GCC include the following.
- Oil and gas: cascade temperature control on heat exchangers and heaters, and local back-up control for critical loops normally run by a PLC or DCS.
- Utilities and power: two-loop control of steam temperature and pressure on auxiliary plant, with Modbus reporting to the plant network.
- Water and wastewater: dosing and pH-related loops that use totalized flow and ratio calculations.
- Manufacturing: heat treat furnaces and atmosphere control using the carbon potential and dewpoint algorithms and programmed ramp and soak profiles.
Selection and compatibility notes for the UDC3500
Select the UDC3500 when you need two loops, cascade control, three inputs or the math and logic functions. For one loop with a remote setpoint, the UDC2500 is usually enough, and for a second input with math, the UDC3200 sits between the two models.
Check the option digits for dual loop, setpoint programming, real time clock, communication type and output count, because several options cannot be combined. For example, the second current output option and the Ethernet option cannot be fitted together. A motor-driven valve using position proportional control needs the dual relay output option and the third analog input.
Installation and commissioning of the UDC3500
Install the UDC3500 as described in the manufacturer manual.
- Allow about 148 mm behind the panel for the case and rear terminals, and fit the four corner screws for the NEMA4X rating.
- Use shielded wiring for every analog input and communication run, and ground shields at one end.
- Set up loops, inputs and alarms from the keypad or through the infrared port and the PC software, then check each input with a calibrator.
- Run Accutune III on each loop at normal load and store the configuration file for replacement use.
Maintenance and service life
The UDC3500 keeps maintenance counters and alarm trip counts that can be read from the front panel or over communications, which helps plan service visits. Clean the front face with a damp cloth, review tuning after any process change, and confirm input accuracy during scheduled calibration. Keep a saved configuration file for each unit.
Related products and ordering notes
Related Honeywell controllers available on request include the UDC2500, UDC3200 and UDC2800. Send the full model code, including option digits, so that Seven Star LLC can quote the correct build.
UDC3500 questions in brief
The UDC3500 is usually chosen for dual-loop and cascade work. It combines up to three analog inputs, math and logic functions and optional Modbus or Ethernet communication. The answers below cover the points buyers ask about most.
Documents and quotation
The manufacturer datasheet for the UDC3500 is available from Seven Star LLC with this listing when it is attached, and it should be read together with the installation manual before any engineering decision. To request a quotation, send an RFQ that states the part number UDC3500, the quantity, the delivery location and, where relevant, the options you need. Seven Star LLC replies with availability and lead time; no price is published on this page.
Other Models in the UDC Range
Seven Star LLC supplies models from the UDC range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell UDC2500 1/4 DIN Universal Digital Controller | Controllers & Data Acquisition | View details |
| Honeywell UDC3200 1/4 DIN Controller with Math Functions | Controllers & Data Acquisition | View details |
| Honeywell UDC3500 1/4 DIN Dual-Loop Digital Controller | Controllers & Data Acquisition | You are viewing this model |
Datasheets & Documents
- Datasheet Honeywell UDC3500 1/4 DIN Dual-Loop Digital Controller Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell UDC3500 1/4 DIN Dual-Loop Digital
Answers from our engineering team on installation, compatibility and integration.
01Can the UDC3500 run two control loops?
Yes. With the dual loop option it provides two independent loops or an internal cascade, with manual, automatic, remote setpoint and cascade modes.
02How many inputs does the UDC3500 have?
It accepts up to three universal analog inputs, which can be configured as one universal plus four high level inputs, and offers four optional digital inputs.
03What accuracy does the UDC3500 offer?
The manufacturer quotes a typical accuracy of 0.10 percent of full scale with 16-bit resolution and six samples per second.
04What communication does the UDC3500 support?
Infrared configuration is standard, and RS422/485 Modbus RTU or Ethernet 10Base-T Modbus TCP/IP are optional.
05How can I request a quotation for the UDC3500?
Send an RFQ with the full model code, quantity and delivery location. Seven Star LLC will reply with availability and lead time; this page shows no price.


















Reviews
There are no reviews yet.