Brand:

ABB S201-C32 1P MCB 32 A C Curve, S200

Description

ABB S201-C32 1P miniature circuit breaker, 32 A curve C

The ABB S201-C32 is a single-pole miniature circuit breaker from the System pro M compact S200 range, rated 32 A with a C tripping characteristic. It protects cables and equipment against overload through a delayed thermal release and against short circuit through an electromagnetic release, and it is current limiting. The ABB type code is S201-C32 and the order code is 2CDS251001R0324. The breaker is designed for residential, commercial and industrial installations, with a rated short-circuit capacity of 6 kA.

In use the ABB S201-C32 switches one live conductor of a single-phase circuit, or one phase of a three-phase distribution board. A single-phase 230 V load drawing up to 32 A corresponds to roughly 7.4 kW at unity power factor; the breaker should be sized to the cable, not to the load alone.

How to read the S201-C32 type designation

The S200 type code works like a short specification, which makes comparing alternatives quick when a drawing or a bill of quantities only lists the code.

Code group Meaning in S201-C32
S201 S200 family, 1P (single-pole)
C Tripping characteristic C, magnetic release at 5 to 10 In
32 Rated current In = 32 A

The characteristic letter is the most commonly mis-ordered part of the code. Curve B (3 to 5 times In) trips earlier and suits long cable runs, while curve D (10 to 20 times In) tolerates heavier inrush such as transformers. Order S201-C32 only when the circuit and the cable calculation justify a C curve.

S201-C32 technical specifications

Parameter Specification
Manufacturer / part number ABB / S201-C32
Order code 2CDS251001R0324
Series System pro M compact S200
Number of poles 1P (single-pole)
Tripping characteristic C; magnetic release 5 to 10 times In (160 to 320 A)
Rated current In 32 A
Rated frequency 50 / 60 Hz
Rated operational voltage Un (IEC/EN 60898-1) 230/400 V AC (1P rated operational voltage per IEC/EN 60898-1)
Rated short-circuit capacity Icn 6 kA
Rated ultimate short-circuit breaking capacity Icu (IEC/EN 60947-2) 10 kA
Rated service short-circuit breaking capacity Ics 7.5 kA
Rated operational voltage Ue (IEC/EN 60947-2) 230 V AC
Rated insulation voltage Ui 440 V AC
Rated impulse withstand voltage Uimp 4 kV (1.2/50 µs)
Energy limiting class 3
Standards IEC/EN 60898-1, IEC/EN 60947-2, UL 1077
UL / CSA rated voltage 1P: 480Y/277 V AC, 60 V DC
Terminal cross-section, solid / stranded up to 35 mm²
Terminal cross-section, flexible up to 25 mm²
Tightening torque 2.8 Nm
Busbar cross-section 10 mm²
Pole dimensions (H x D x W) 88 x 69 x 17.5 mm per pole
Width of the 1P 17.5 mm
Mounting 35 mm DIN rail (EN 60715), any mounting position
Weight per piece (catalog) 0.125 kg
Degree of protection IP20; IP40 in an enclosure with cover
Ambient temperature -25 to +55 °C
Storage temperature -40 to +70 °C
Mechanical endurance 20,000 operations
Electrical endurance (AC) 10,000 operations

How the S201-C32 protects the circuit

Two mechanisms work together. A bimetal element heats in proportion to the current and bends slowly when the load stays above 32 A, so a modest overload is tolerated for a while and a larger one trips sooner. For a short circuit, an electromagnetic release acts without delay once the current reaches the magnetic threshold of the C curve, which for this breaker is 5 to 10 times In, that is 160 A to 320 A. Between the two regions the breaker follows the inverse-time characteristic published for the S200 series.

The contacts open quickly enough to limit the energy let through, and the S200 range reports energy limiting class 3 for B and C types up to 40 A, which reduces thermal and mechanical stress on cables and busbars during a fault. A red and green contact position indicator on the toggle shows the real contact state, and the toggle can be sealed to prevent tampering.

Choosing curve C for the S201-C32

ABB positions the C characteristic for protection of resistive and inductive loads with low inrush. Typical uses are general lighting, socket outlets, small motors with moderate starting current, heaters, control-panel supplies and the majority of commercial and industrial final circuits.

Curve B (3 to 5 times In) trips earlier and suits long cable runs, while curve D (10 to 20 times In) tolerates heavier inrush such as transformers. The magnetic threshold of this 32 A breaker is 160 A to 320 A, so the available short-circuit current at the far end of the cable must exceed the upper figure for the instantaneous trip to be certain. This is the check that decides between curves B, C and D on long or high-impedance circuits.

Selection and ordering checklist for the S201-C32

  • Confirm the pole count: single-pole for one live conductor of a single-phase circuit, or one phase of a three-phase distribution board.
  • Confirm the rated current against the cable cross-section and installation method, not only the load.
  • Confirm the characteristic letter (C) against the starting or inrush current of the load.
  • Check that the prospective short-circuit current at the board does not exceed the 6 kA rated capacity of this version; the S200 M and S200 P versions cover higher levels.
  • Check the supply: 230/400 V AC (1P rated operational voltage per IEC/EN 60898-1).
  • Allow 17.5 mm of DIN-rail width and note that the breaker is rated for use between -25 and +55 °C.
  • List any auxiliary or signal contacts, shunt trips or motor operators that will be fitted to the S200 range alongside it.

Installation, commissioning and maintenance

The S201-C32 snaps onto a 35 mm DIN rail with a fast clip and can be mounted in any position. The bi-directional cylinder-lift terminals accept conductors up to 35 mm² solid or stranded and 25 mm² flexible, and a busbar slot at the back takes 10 mm² busbar. Tighten the terminal screws to 2.8 Nm with a No. 2 Pozidrive screwdriver and re-check after the first thermal cycle of the installation, because loose terminals are the most common cause of heating in distribution boards.

After installation, operate the toggle to confirm the contact position indicator changes between red and green, test downstream circuits at the board before energising, and record the setting in the circuit schedule. In service, a periodic thermal scan of the terminals and a manual operation of the breaker once a year help to detect deterioration early. If the breaker trips, find and correct the cause before resetting; repeated resets on a fault are a safety risk.

Typical applications in Oman and the GCC

Distribution boards in Oman and the GCC work in high ambient temperatures, dust and, near the coast, humid and salty air. The S200 range is specified for -25 to +55 °C and for damp-heat cycling, so the S201-C32 fits the final-circuit and sub-distribution duties found in commercial buildings, hotels, hospitals, industrial plants, utilities, oil and gas support facilities and water and desalination sites. Single-pole units are common for lighting and socket final circuits and as per-phase protection of small loads.

In hot panels, remember that the thermal trip point moves with temperature. ABB gives a reference temperature for the tripping curves, so a board that runs well above that temperature may need breakers derated or a larger enclosure with better ventilation. Group several breakers side by side only after checking the derating guidance for the board.

Related S200 breakers and variants

The same rated current and characteristic is available in other pole counts: S202-C32, S203-C32, S204-C32. Within the single-pole family you can step to a neighbouring rating if the cable or load changes, and to the S200 M and S200 P versions where fault levels are higher.

Characteristic Magnetic trip Intended duty
B 3 to 5 times In Long cable runs, people and cable protection
C 5 to 10 times In Resistive and inductive loads, low inrush
D 10 to 20 times In High inrush, transformers, lamps

Information to send with an RFQ

To confirm availability and lead time for the S201-C32, send the exact type code, the quantity, the delivery location and the required delivery date. If the breaker is part of a board, add the pole count, rated current, characteristic and any accessories, so that one order covers the full set. Photos of the nameplate of an existing breaker help us avoid a mismatch on legacy installations.

Documents and quotation

The official ABB data sheet for the S 200 series (document 2CDC002157D0202, English) is attached on this page as a PDF and applies to the ABB S201-C32. It covers the full System pro M compact S 200 and S 200 M range: tripping characteristics B, C, D, K and Z, rated currents from 0.5 to 63 A, breaking capacity to IEC/EN 60898-1 and IEC/EN 60947-2, UL 1077 data, terminal capacity, accessories and dimension drawings. Check the rating and the characteristic against your circuit before ordering, then send us the quantity and the delivery location for a quotation.

Quotations are prepared on request, with the technical details above matched to your specification.

Other Models in the Abb S200 Mcb Range

Seven Star LLC supplies models from the Abb S200 Mcb range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
ABB S203-C16 3P MCB 16 A C Curve, S200Circuit BreakersView details
ABB S204-C32 4P MCB 32 A C Curve, S200Circuit BreakersView details
ABB S201-C10 1P MCB 10 A C Curve, S200Contactors & Overload RelaysView details
ABB S201-C20 1P MCB 20 A C Curve, S200Contactors & Overload RelaysView details
ABB S201-C25 1P MCB 25 A C Curve, S200Contactors & Overload RelaysView details
ABB S201-C32 1P MCB 32 A C Curve, S200Contactors & Overload RelaysYou are viewing this model
ABB S201-C40 1P MCB 40 A C Curve, S200Contactors & Overload RelaysView details
ABB S201-D16 1P MCB 16 A D Curve, S200Contactors & Overload RelaysView details
ABB S202-C16 2P MCB 16 A C Curve, S200Contactors & Overload RelaysView details
ABB S202-C25 2P MCB 25 A C Curve, S200Contactors & Overload RelaysView details
ABB S202-C32 2P MCB 32 A C Curve, S200Contactors & Overload RelaysView details
ABB S202-C40 2P MCB 40 A C Curve, S200Contactors & Overload RelaysView details
ABB S202-B16 2P MCB 16 A B Curve, S200Contactors & Overload RelaysView details
ABB S202-D16 2P MCB 16 A D Curve, S200Contactors & Overload RelaysView details
ABB S203-C10 3P MCB 10 A C Curve, S200Contactors & Overload RelaysView details
ABB S203-C20 3P MCB 20 A C Curve, S200Contactors & Overload RelaysView details
ABB S203-C25 3P MCB 25 A C Curve, S200Contactors & Overload RelaysView details
ABB S203-C50 3P MCB 50 A C Curve, S200Contactors & Overload RelaysView details
ABB S203-B16 3P MCB 16 A B Curve, S200Contactors & Overload RelaysView details
ABB S203-B32 3P MCB 32 A B Curve, S200Contactors & Overload RelaysView details
ABB S203-D16 3P MCB 16 A D Curve, S200Contactors & Overload RelaysView details
ABB S203-D25 3P MCB 25 A D Curve, S200Contactors & Overload RelaysView details
ABB S204-C16 4P MCB 16 A C Curve, S200Contactors & Overload RelaysView details
ABB S204-C20 4P MCB 20 A C Curve, S200Contactors & Overload RelaysView details
ABB S204-C25 4P MCB 25 A C Curve, S200Contactors & Overload RelaysView details
Datasheets & Documents
  • PDF Datasheet ABB S 200 / S 200 M Miniature Circuit Breaker Data Sheet (PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.

ABB company profile

Formed 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50%
ASEA Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators
Brown, Boveri & Cie Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri
Headquarters Zurich, Switzerland; ABB Ltd became the group holding company in 1999
Ownership Public company listed on SIX Swiss Exchange and Nasdaq Stockholm
Brands in the group Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers
Product families Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots

Milestones

  • 1883: ASEA is founded in Västerås, Sweden.
  • 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
  • 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
  • 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
  • 2011 and 2017: Baldor Electric and B&R join ABB.
  • 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.

Choosing an ABB drive

ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.

Where ABB products are used

In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.

ABB products we list

Family Examples
AC drives ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module
Breakers, motor control and protection SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay
Flow measurement ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500
Pressure, temperature and level 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge
Analysers Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210
Control systems and actuators AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000

Ordering ABB products: what we need

Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.

Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.

Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.

FAQ

Questions about the ABB S201-C32 1P MCB 32 A C Curve, S200

Answers from our engineering team on installation, compatibility and integration.

01What does the S201-C32 code mean?
S201 identifies the S200 family in a single-pole version, C is the C tripping characteristic and 32 is the rated current in amperes. The ABB order code is 2CDS251001R0324.
02At what current does the S201-C32 trip instantly?
The curve C electromagnetic release acts at 5 to 10 times In, which for 32 A is 160 A to 320 A. Below that range the thermal release handles overloads with a time delay.
03What short-circuit capacity does the S201-C32 have?
The rated short-circuit capacity Icn is 6 kA under IEC/EN 60898-1. Under IEC/EN 60947-2 the ultimate breaking capacity Icu is 10 kA and the service capacity Ics is 7.5 kA.
04How wide is the S201-C32 on the DIN rail?
Each pole is 17.5 mm wide, so the 1P measures 17.5 mm. It mounts on a 35 mm DIN rail with a fast clip and can be installed in any position.
05Which conductors fit the S201-C32 terminals?
The terminals accept up to 35 mm² solid or stranded and 25 mm² flexible conductors, with a recommended tightening torque of 2.8 Nm. A busbar slot takes 10 mm² busbar.