- Automation & ControlView all 1,684 products
- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Isolator & Barrier
- Industrial Computers
- Servo Drives
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Automation Software
- Machine Vision
- Robotics
Brand: Rosemount
Rosemount 3051SFP Integral Orifice Flow Meter
Description
Rosemount 3051SFP integral orifice flow meter for 1/2 to 1-1/2 in. lines
The Rosemount 3051SFP is a factory-assembled flow meter for small pipes: a precision honed pipe section with a self-centering orifice plate, a manifold and a Rosemount 3051S transmitter. In lines of 1/2, 1 and 1-1/2 in. (15, 25 and 40 mm), an ordinary orifice plate is easily misaligned, and the error grows as the bore gets smaller. The 3051SFP removes that installation error by building the plate into the meter run, and it reports compensated mass flow directly when a flow calculation measurement type is chosen.
Seven Star LLC supplies Rosemount instruments in Oman and the GCC as an independent supplier in Muscat. Small-bore meters have more ordering options than most buyers expect, particularly bore size, so the sections below explain each step.
How a 3051SFP model code is read
The manufacturer shows 3051SFP 1 F 010 W3 S 0150 D3 1 J A 1A 3 M5 as a typical code. Reading it from left to right:
| Code in example | Meaning |
|---|---|
| 3051SFP | Integral orifice flow meter |
| 1 | Measurement type 1: fully compensated mass and energy flow |
| F | 316 SST, enhanced support body |
| 010 | Line size 1 in. (25 mm) |
| W3 | Pipe ends: flanged, Class 300 RF ASME B16.5, weld-neck |
| S | Orifice plate material 316/316L SST |
| 0150 | Bore size 0.150 in. (3.81 mm) for a 1 in. pipe |
| D3 | Transmitter connection: direct mount, 3-valve manifold, SST |
| 1 | Differential pressure range 1: 0 to 25 inH2O |
| J | Static pressure: gauge, –14.20 to 800 psig |
| A | Output: 4–20 mA HART |
| 1A | Plantweb housing, aluminum, 1/2–14 NPT |
| 3 | Performance class: Ultra for Flow |
| M5 | Plantweb LCD display |
In the manufacturer table, Ultra for Flow is only available with DP ranges 2 and 3 and silicone fill. The sample code shows range 1 as a decoding exercise, so always confirm a real configuration with the sizing tool.
3051SFP technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Rosemount 3051SFP Integral Orifice Flow Meter |
| Line sizes | 1/2 in. (15 mm), 1 in. (25 mm), 1-1/2 in. (40 mm) |
| Body | 316 SST enhanced support body; A312 Gr 316/316L pipe, A182 Gr 316/316L flange |
| Orifice plate | 316/316L SST, Alloy C-276 or Alloy 400 |
| Bore sizes | 0.010 to 1.184 in., by line size; special bore available |
| Process connections | NPT female, socket weld, NPT or beveled pipe ends, EN and ASME flanges (Class 150 to 900) |
| Ultra for Flow accuracy, bore < 0.160 | ±2.55 % of flow rate at 14:1 |
| Ultra for Flow, bore 0.160 to < 0.500 | ±1.55 % of flow rate at 14:1 |
| Ultra for Flow, bore 0.500 to 1.000 | ±1.05 % of flow rate at 14:1 |
| Ultra for Flow, bore > 1.000 | ±1.55 % of flow rate at 14:1 |
| Classic MV accuracy | ±2.65 %, 1.70 %, 1.25 %, 1.70 % for the same four bore bands at 8:1 |
| Process temperature, direct mount | –40 to 550 °F (–40 to 288 °C) |
| Process temperature, remote mount | –40 to 572 °F (–40 to 300 °C) with PTFE O-rings |
| Extended temperature | –112 to 850 °F (–80 to 454 °C), remote mount only, with option G |
| Output options | 4–20 mA HART, FOUNDATION Fieldbus, WirelessHART |
| Vibration structural limit | IEC 60068-2-6; transmitter assembly weight not above 12.6 lb (5.72 kg) |
Bore size and accuracy on the 3051SFP
The bore code is four digits and is the diameter in thousandths of an inch. For a 1/2 in. pipe the stocked bores run from 0.066 to 0.340 in., with 0.010, 0.014, 0.020 and 0.034 in. as non-starred options. A 1 in. pipe takes 0.150 to 0.800 in. and a 1-1/2 in. pipe takes 0.295 to 1.184 in. The sizing tool chooses the bore from your flow, pressure and temperature.
The accuracy bands above show why the choice matters: the best figure comes from bores between 0.500 and 1.000 in., while very small bores carry the largest uncertainty. The 1/2 in. quadrant-edge plates cover the smallest bores. A 3051SFP is most useful when the line is small and a decent percentage-of-reading accuracy is needed without long straight pipe.
3051SFP selection and ordering checklist
- Line size, schedule and pipe end style: threaded, socket weld, beveled or flanged with class and face.
- Fluid, operating pressure, temperature and flow range so the bore is sized correctly.
- Plate material for corrosion and NACE needs, and whether an RTD thermowell is wanted.
- Direct or remote mount, and a 3-valve or 5-valve manifold in SST or Alloy C-276.
- Measurement type, DP range, static pressure range, output and housing.
- High-temperature bolting (option G) if process temperature goes above standard limits.
- Hydrostatic test, material traceability, PMI and inspection certificates for project documents.
Installing and maintaining the 3051SFP
The 3051SFP arrives fully assembled, configured and leak tested, so site work is the pipe connection and the electrical hookup. Weld-neck or threaded ends tie into the line like a short spool. Support the transmitter weight, keeping the assembly within the structural weight limit, and use a bracket for remote mount. After a repair, replace the gaskets and O-rings of the primary element whenever it is disassembled.
Check manifold valves, impulse connections and zero during shutdowns. Because the plate is built into the body, ask us about spare gasket and O-ring sets when you order. Keep the factory configuration data sheet and the sizing report with the plant files.
3051SFP and the Rosemount 1195 integral orifice element
The Rosemount 1195 is the same integral orifice primary element sold without the full flow meter, and it can be ordered assembled to a transmitter. The 3051SFP adds the 3051S transmitter with MultiVariable flow calculation as a single unit. For larger lines, the 3051SFC compact orifice and the 3051SFA Annubar are the other 3051SF choices.
3051SFP applications in Oman and the GCC
Small lines carry chemical injection, fuel gas to burners, steam to tracing, sample conditioning loops and utility air in refineries, gas plants and power stations. Dosing lines in desalination plants also fall in the 1/2 to 1-1/2 in. range. Direct flow measurement in these lines can save the cost of orifice flanges, a separate flow computer and long pipe runs.
For outdoor installations in Gulf summer sun, choose a stainless steel Plantweb housing, shade the unit when possible, and use remote mount where the line is hot enough to push the transmitter toward its limits.
Information to send with a 3051SFP RFQ
- Fluid, flow range, pressure and temperature, and line size with pipe schedule.
- Pipe end connection type, flange standard, class and facing.
- Plate material, bore size if already sized, or the process data for sizing.
- Transmitter ranges, output, housing, display and hazardous-area approval.
- Test certificates required, quantity and delivery site.
Documents and quotation
The manufacturer product data sheet for the Rosemount DP flow meters and primary elements is attached on this page. It includes the 3051SFP ordering tables, bore list and temperature limits.
To request a quotation, send the model code or the process data. Seven Star LLC will review the configuration and respond with availability for Oman and the GCC.
Other Models in the Rosemount 3051sf Dp Flow Range
Seven Star LLC supplies models from the Rosemount 3051sf Dp Flow range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Rosemount 3051SFA Annubar Flow Meter | Flowmeters | View details |
| Rosemount 3051SFC Compact Orifice Flow Meter | Flowmeters | View details |
| Rosemount 3051SFP Integral Orifice Flow Meter | Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet Rosemount DP Flow Meters and Primary Elements Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile
| Established | 1956, Minnesota, USA, as Rosemount Engineering Company |
|---|---|
| Founders | Frank D. Werner, Robert E. Keppel and Vernon H. Heath |
| Ownership | Acquired by Emerson in 1976; now an Emerson brand |
| Product families | Pressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments |
Milestones
- 1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
- 1969: The Rosemount 1151 analog pressure transmitter is introduced.
- 1976: Emerson acquires Rosemount.
- 1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
- 2001: The 3051S generation follows.
Rosemount products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure transmitters | 3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm seals | Pressure, differential pressure and remote seal measurement |
| DP flow and DP level | 3051CF flowmeter, 3051L, 3051SAL | Flow through primary elements, and level in pressurised vessels |
| Temperature | 644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-input | Process temperature, high-density multipoint and tank temperature |
| Radar and level | 5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gauges | Level in tanks, separators and custody transfer tank gauging |
| Level switches | 2120, 2140, 2160 wireless, 702 discrete transmitter | High and low level alarms, overfill protection and pump protection |
| Flowmeters | 8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquid | Water, steam and gas flow, and fiscal gas and liquid metering |
| Liquid analysis | 396P TUpH, 396PVP, 499ACL chlorine sensor | pH, ORP and free chlorine in water and process streams |
Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.
FAQ
Questions about the Rosemount 3051SFP Integral Orifice Flow Meter
Answers from our engineering team on installation, compatibility and integration.
01What is the Rosemount 3051SFP?
It is an integral orifice flow meter for 1/2, 1 and 1-1/2 in. lines. A precision honed meter run with a self-centering plate is assembled with a 3051S transmitter and manifold.
02Why use an integral orifice in small lines?
A separate orifice plate in a small pipe is easy to misalign, and the error is magnified at small bores. The built-in self-centering plate removes that source of error.
03What accuracy can the 3051SFP achieve?
With Ultra for Flow, the best band is bores from 0.500 to 1.000 in. at ±1.05 % of flow rate over 14:1. Bores below 0.160 in. are listed at ±2.55 %.
04What process temperature can the 3051SFP handle?
Standard direct mount is –40 to 550 °F (–40 to 288 °C). Remote mount with high-temperature bolting option G extends the range to –112 to 850 °F (–80 to 454 °C).
05How does the 3051SFP differ from the Rosemount 1195?
The 1195 is the integral orifice primary element and can be ordered with or without a transmitter. The 3051SFP is the complete flow meter with a 3051S MultiVariable-capable transmitter.


















Reviews
There are no reviews yet.