Brand: ABB
ABB ACS880-01-087A-3 Wall-Mounted Drive 45 kW 87 A
Description
Where the ACS880-01-087A-3 fits
The ACS880-01-087A-3 is an ABB ACS880-01 wall-mounted single drive for 380 to 415 V supplies. Nominal output is 87 A at 45 kW and the mechanical size is frame R5. Typical jobs are mills and extruders and heavy conveyors and mixers. Because the choke and Safe Torque Off are already inside, the drive can be mounted on the wall without extra filter hardware.
Technical specifications
| Parameter | Specification |
|---|---|
| Type designation | ACS880-01-087A-3 |
| Product family | ACS880 industrial drives, -01 = wall-mounted single drive |
| Typical motor power / nominal current | 45 kW / 87 A |
| Light-overload rating | 83 A = 45 kW |
| Heavy-duty use | 37 kW, 72 A |
| Peak current IMAX | 122 A |
| Frame size | R5 |
| IP21 height, width, depth, weight | 730 mm with cable box (596 mm without), 203 mm, 274 mm, 22.8 kg |
| IP55 option | 730 x 203 x 344 mm, 23.4 kg |
| Sound level | 64 dB(A) |
| Heat dissipation | 1129 W |
| Cooling air flow | 280 m3/h |
| Brake chopper | A selectable internal option, order code +D150 |
| Brake resistor type | SAFUR90F575, 8 ohm, 1800 kJ |
| Minimum brake resistance | 8 ohm for 45 kW braking power |
| Sine filter type | B84143V0095R229 (rated 77 A) |
Ratings, mounting and cooling of the ACS880-01-087A-3
From the ratings table: nominal 87 A / 45 kW, light overload 83 A / 45 kW, heavy duty 72 A / 37 kW, IMAX 122 A. Light overload suits pumps and fans, whose torque falls with speed, while heavy duty is the choice for crushers, extruders and conveyors that need high starting torque. Match the motor current and check ambient temperature and altitude derating in the manual.
The standard IP21 body of frame R5 measures 730 mm high with the cable entry box (596 mm without it), 203 mm wide and 274 mm deep, and weighs 22.8 kg. The IP55 version for dusty and wet places is 730 x 203 x 344 mm and 23.4 kg. Heat dissipation is 1129 W at 90% frequency and full motor current, with 280 m3/h of cooling air and 64 dB(A) of noise.
Brake chopper, EMC filter and output filters
Dynamic braking: chopper a selectable internal option, order code +D150; resistor SAFUR90F575 (8 ohm, 1800 kJ, 4.5 kW continuous); minimum 8 ohm at 45 kW. Order +E202 for a C2 filter, +E200 for C3 or +E201 for IT networks; the standard drive meets C4 on grounded networks. A sine filter, type B84143V0095R229, is listed for 77 A at 37 kW and is useful with long motor cables or submersible pumps.
Control connections include 2 analog inputs, 2 analog outputs, 6 digital inputs, 2 configurable digital inputs/outputs, 3 relay outputs, Safe Torque Off and an EIA-485 link that serves as Modbus RTU or drive-to-drive link. The control unit has three slots for adapters, I/O extension, feedback and safety modules.
Related ABB products: ABB ACS550-01-087A-4 AC Drive 45 kW 87 A, ABB ACQ580-01-089A-4 Water Drive 45 kW 89 A, ABB ACQ580-01-018A-4 Water Drive 7.5 kW 17 A, ABB ACS580-01-018A-4 AC Drive 7.5 kW 17 A, ABB ACQ580-01-039A-4 Water Drive 18.5 kW 38 A and ABB ACS580-01-07A3-4 AC Drive 3 kW 7.2 A.
Documents and quotation
This page follows ABB’s ACS880 single drives catalogue (3AUA0000098111, linked) plus the ABB product page for the ACS880-01-087A-3. Seven Star LLC quotes the ACS880-01-087A-3 from Muscat once it has the motor nameplate, supply voltage and option list. Confirm before ordering: plus codes, motor current, enclosure class, filters, brake resistor and derating for temperature and altitude. Browse neighbouring ratings in AC drives; for a lighter general purpose range see the ABB ACS580 drive.
Datasheets & Documents
- Catalog ABB ACS880 single drives catalog (3AUA0000098111) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
Related products
Frequently Asked Questions
ABB lists 87 A nominal (45 kW), 83 A (45 kW) for light overload, 72 A (37 kW) for heavy duty and 122 A maximum output current.
It is frame R5: 730 mm high with cable entry box, 203 mm wide, 274 mm deep and 22.8 kg; the IP55 version is 730 x 203 x 344 mm and 23.4 kg.
The brake chopper is a selectable internal option, order code +D150; the catalogue lists SAFUR90F575 (8 ohm) and a minimum resistance of 8 ohm.
The catalogue gives 1129 W of heat dissipation, 280 m3/h of air flow and 64 dB(A) noise.
The catalogue lists +E202 for C2, +E200 for C3 and +E201 for ungrounded networks; category C4 is standard on 380 to 500 V ACS880-01 drives.