Endress+Hauser iTEMP TMT82 HART Temperature Transmitter

Description

Overview of the Endress+Hauser iTEMP TMT82

The Endress+Hauser iTEMP TMT82 is a two-wire HART temperature transmitter with two universal sensor inputs. It converts signals from resistance thermometers, thermocouples, resistance transmitters and millivolt sources into a 4–20 mA output with HART 7 communication, and it is offered as a head transmitter for terminal heads of form B (flat face) to DIN EN 50446, as a 17.5 mm wide DIN rail module for cabinets, or in a two-compartment field housing with display. Technical Information TI01010T describes the device as SIL 2 certified (SC3) according to IEC 61508:2010 and approved for hazardous areas under FM, CSA, ATEX, IECEx, EAC, NEPSI and DNV.

Seven Star LLC supplies the Endress+Hauser iTEMP TMT82 to oil and gas operators, power stations, desalination plants and EPC contractors across the Sultanate of Oman and the GCC, with engineering support in Muscat. The transmitter is a common choice for new thermowell assemblies and for upgrading older analog transmitters to HART diagnostics without changing the sensor.

Operating Principle of the Endress+Hauser iTEMP TMT82

The Endress+Hauser iTEMP TMT82 records and electronically converts the input signals used in industrial temperature measurement. Two independent measuring channels accept Pt100, Pt200, Pt500 and Pt1000 RTDs to IEC 60751, nickel and copper sensors, Callendar-Van Dusen coefficients, thermocouple types A, B, C, D, E, J, K, L, N, R, S, T and U, resistance from 10 to 2000 Ω and voltage from –20 to 100 mV. The converted value is transmitted as a temperature-linear 4–20 mA signal with superimposed HART FSK communication, and input and output are galvanically isolated with 2 kV AC.

The second channel is what makes the device valuable in critical service. Sensor backup switches automatically to the second sensor if the primary sensor fails, drift warning or alarm compares the two sensors against a limit, and the transmitter can also calculate mean or differential values or switch between sensors used in different temperature ranges. Corrosion detection per NAMUR NE 89 identifies rising wire resistance before the reading is corrupted, low voltage detection prevents a false output when supply is insufficient, and failure signalling follows NAMUR NE 43 with status per NE 107.

Engineering Design of the Endress+Hauser iTEMP TMT82

The head transmitter fits directly into the terminal head of a thermometer, while the DIN rail version mounts on a TH35 rail to EN 60715 inside marshalling or control cabinets. Housings are polycarbonate with screw or push-in terminals; the push-in option allows tool-free wiring during installation and maintenance. The head version runs from 11 to 42 V DC (11 to 32 V in SIL mode) and the DIN rail version from 12 to 42 V DC, with current consumption of 23 mA or less. Field housings such as the aluminium TA30A or the flameproof TA30H provide IP66/68 protection for remote mounting.

Configuration is carried out over HART with FieldCare, DeviceCare or a handheld, and the head transmitter can be fitted with the plug-on TID10 display. Vibration resistance is 2 to 100 Hz at 4 g for the head transmitter to DNVGL-CG-0339, which supports skid and marine installations, and the standard ambient temperature range of the Endress+Hauser iTEMP TMT82 is –40 to +85 °C, with –50 °C and –52 °C options.

Key Features of the Endress+Hauser iTEMP TMT82

The following points from TI01010T explain where the Endress+Hauser iTEMP TMT82 adds value in a measuring point:

  • Two universal inputs for RTD, thermocouple, resistance and millivolt signals in any combination listed by the manufacturer.
  • HART 7 communication with multi-drop addressing from 0 to 63 outside SIL mode.
  • SIL 2 certification to IEC 61508:2010, with a dedicated Functional Safety Manual FY01105T.
  • Sensor backup, drift alarm, mean value and differential measurement from two sensors.
  • Typical measurement error of 0.07 °C digital for a Pt100 from 0 to 200 °C, and 0.25 °C for a type K thermocouple from 0 to 800 °C.
  • Sensor-transmitter matching with Callendar-Van Dusen coefficients for the highest system accuracy.
  • Corrosion detection per NAMUR NE 89, low voltage detection and NE 43 failure currents.
  • Head, DIN rail and field-housing versions with push-in terminals and FM, CSA, ATEX, IECEx and NEPSI approvals.

Industrial Applications of the Endress+Hauser iTEMP TMT82

The Endress+Hauser iTEMP TMT82 is used on process lines, heat exchangers, compressors, turbines, reactors and storage tanks where a temperature point needs HART diagnostics or a safety rating. Dual-sensor thermowell inserts with sensor backup are widely used on critical loops in refineries, gas processing plants and power stations, because a failed element no longer stops the loop. In Oman these duties include upstream production facilities, the refinery and petrochemical complexes in Sohar, LNG and gas plants, and independent water and power projects along the coast.

Seven Star LLC supplies the transmitter as a loose part or as part of a complete temperature measuring point. Buyers can combine it with the Endress+Hauser TR10 Omnigrad M RTD thermometer or the iTHERM ModuLine TM101, or select the Endress+Hauser TMT162 field transmitter where a dual-compartment housing with display is preferred.

Technical Specifications of the Endress+Hauser iTEMP TMT82

Key data of the Endress+Hauser iTEMP TMT82 from Technical Information TI01010T are summarised below.

Parameter Specification
Model iTEMP TMT82
Inputs 2 universal: RTD, TC, resistance (10 to 2000 Ω), voltage (–20 to 100 mV)
RTD range (Pt100, IEC 60751) –200 to 850 °C, minimum span 10 K
Thermocouple types A, B, C, D, E, J, K, L, N, R, S, T, U
Output 4–20 mA or 20–4 mA with HART 7
Failure signal ≤ 3.6 mA or ≥ 21 mA per NAMUR NE 43
Galvanic isolation 2 kV AC for 1 minute, input to output
Supply voltage Head: 11 to 42 V DC; DIN rail: 12 to 42 V DC
Response time RTD 0.9 to 1.5 s; TC 1.1 s
Ambient temperature –40 to +85 °C (options to –52 °C)
Functional safety SIL 2 (SC3) per IEC 61508:2010
Degree of protection IP20 (head/DIN rail); IP67 in field housing with terminal compartment
Mounting Form B terminal head (DIN EN 50446), TH35 DIN rail, field housing

How to Order

To order the Endress+Hauser iTEMP TMT82, send Seven Star LLC the mounting version, sensor type and wiring, measuring range, hazardous area approval and any SIL requirement, and our instrumentation division will return a formal quotation with lead time. Technical Information TI01010T can be downloaded from this page. Seven Star LLC is a trusted supplier of Endress+Hauser temperature products in Oman and the GCC, with engineering support in Muscat for configuration and commissioning.

Datasheets & Documents
  • PDF Datasheet Endress+Hauser iTEMP TMT82 Technical Information (TI01010T) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand
Level, flow and pressure measurement account for most of the Endress+Hauser instruments engineers ask us about, and each device is defined by the order code on its nameplate. Endress+Hauser, founded in 1953 and based in Reinach, Switzerland, builds process instrumentation for liquids, gases and bulk solids. Seven Star LLC is an independent supplier listing Endress+Hauser (E+H) flowmeters, radar and vibronic level instruments, pressure and temperature transmitters and liquid analysis equipment for plants in Oman and the GCC.

Endress+Hauser product families on this page

Level is the largest group: Micropilot free-space radar (FMR10B, FMR62 and the FMR67 for bulk solids, all 80 GHz), Levelflex guided radar (FMP50, and the FMP55 for interface measurement), the Liquiphant FTL51 vibronic point level switch and the Prosonic S FMU90 ultrasonic transmitter. Flow covers Proline Promag electromagnetic flowmeters (Promag P 300, Promag W 400) and the Prowirl F 200 vortex meter. Pressure is represented by the Cerabar PMP51B, temperature by the iTEMP TMT82 HART transmitter. For liquid analysis the listing has the Liquiline CM444 multiparameter transmitter and Memosens sensors such as the CPS11E pH electrode.

Where Endress+Hauser instruments are used

Water and wastewater plants rely on Promag W meters, radar level and Liquiline analysis. Oil and gas, chemical and power plants specify Levelflex and Micropilot on tanks and separators, Prowirl on steam and gas, and Cerabar on process lines. Food and pharmaceutical producers use hygienic versions of the same families, and cement and mining sites use the FMR67 on silos.

Ordering Endress+Hauser instruments: what we need

Send the order code and, for a replacement, the serial number from the nameplate. The extended order code is better still, because it spells out every option. Without a code we need the medium, pressure and temperature, measuring span, process connection, wetted materials, output signal or fieldbus, power supply, display and the hazardous area approval required. For flowmeters add line size and liner, for radar the tank height and nozzle size.

Frequently Asked Questions

What is the Endress+Hauser iTEMP TMT82?
It is a two-wire HART 7 temperature transmitter with two universal inputs that converts RTD, thermocouple, resistance and millivolt signals into a 4-20 mA output. It is available as a head transmitter, DIN rail module or in a field housing.
Which sensors can be connected to the TMT82?
It accepts Pt100, Pt200, Pt500 and Pt1000 RTDs, nickel and copper sensors, thermocouple types A, B, C, D, E, J, K, L, N, R, S, T and U, resistance from 10 to 2000 ohm and voltage from -20 to 100 mV.
What are the benefits of the two inputs?
With two sensors the TMT82 provides sensor backup if one element fails, drift warning when the sensors deviate, mean value or differential measurement, and temperature-dependent switching between sensors.
Is the iTEMP TMT82 suitable for safety and hazardous area applications?
Yes. It is SIL 2 certified according to IEC 61508:2010 and has hazardous area approvals including FM, CSA, ATEX, IECEx, EAC and NEPSI, depending on the ordered version.
Does Seven Star LLC supply the Endress+Hauser iTEMP TMT82 in Oman?
Yes. Seven Star LLC is a trusted supplier of Endress+Hauser temperature instruments and supplies the iTEMP TMT82 with quotations and engineering support in Muscat across Oman and the GCC.