Endress+Hauser Memosens CPS11E Digital pH Sensor

Description

Overview of the Endress+Hauser Memosens CPS11E Digital pH Sensor

The Endress+Hauser Memosens CPS11E is a digital pH sensor with Memosens 2.0 technology for standard applications in process technology and environmental engineering. Endress+Hauser designs it for long-term monitoring and limit control in processes with stable conditions, including the chemical industry with strong acids and bases, power plants and flue gas cleaning, oil and gas, incinerators, water and wastewater treatment, boiler feedwater, cooling water and drinking water. A large ring-shaped PTFE junction keeps maintenance low, and the sensor is rated for pressures up to 17 bar absolute.

As the official trusted supplier and regional supplier for Endress+Hauser, Seven Star LLC proudly supplies the Endress+Hauser Memosens CPS11E to customers across the Sultanate of Oman and the wider GCC. Seven Star LLC provides the Technical Information TI01493C with every offer, so that water and process engineers in Muscat, Sohar and Salalah can match glass type, reference system and length to the application.

Measuring Principle of the Endress+Hauser Memosens CPS11E

The Endress+Hauser Memosens CPS11E measures pH through its membrane glass. The glass develops an electrochemical potential that depends on the pH of the medium because H+ ions accumulate selectively on the outer layer of the membrane, and an integrated Ag/AgCl reference system acts as the reference electrode. The measured voltage is converted to a pH value with the Nernst equation, and an integrated NTC 30K temperature sensor supplies the temperature for compensation.

What distinguishes Memosens is the digital signal path. The measured value is digitized inside the sensor and passed to the transmitter through a non-contact inductive connection in the plug-in head. Moisture cannot cause corrosion at the connection or distort the reading, the transmitter is galvanically decoupled from the medium, and a sensor failure or an interrupted connection is reliably detected and reported. The sensor must always be connected to a transmitter with Memosens technology, such as the Liquiline CM42 or CM44x, using the Memosens cable CYK10 or CYK20.

Engineering Design of the Endress+Hauser Memosens CPS11E

Three process glasses are offered. Application A covers pH 1 to 12 at –15 to +80 °C, application B covers pH 0 to 14 at 0 to +135 °C and is also suitable for highly alkaline media, and application F covers pH 0 to 10 at 0 to +70 °C for media containing hydrofluoric acid. Pressure ratings are 0.8 to 17 bar absolute for A and B and 0.8 to 7 bar absolute for F. Four reference systems are described: AA with 3M KCl, AS with saturated KCl for media of low conductivity, TA with an Ag+-free ion trap against poisoning, and TS combining both.

The 12 mm shaft is available in installed lengths of 120, 225, 360 and 425 mm, weighing 40 to 100 g. The process coupling is Pg 13.5 in glass-fiber reinforced PPS with an FKM O-ring, and the plug-in head withstands 16 bar. The degree of protection is IP 68 (10 m water column, 45 days), and the sensor must be installed at an angle of at least 15° from the horizontal so that no air bubble forms. Hand-tightening with 3 Nm is specified in Endress+Hauser assemblies.

Key Features of the Endress+Hauser Memosens CPS11E

The Endress+Hauser Memosens CPS11E offers the following capabilities according to the manufacturer’s documentation:

  • Memosens 2.0 digital signal transmission with sensor data stored in the sensor, including calibration history and sensor load.
  • Laboratory calibration with quick exchange of pre-calibrated sensors, which raises the availability of the measuring point.
  • Process glass options for standard, highly alkaline and hydrofluoric acid applications.
  • Large PTFE ring junction that is robust, low-maintenance and sterilizable.
  • Pressure resistance up to 17 bar absolute and temperature capability up to 135 °C with the application B glass.
  • Reference systems with salt storage for low-conductivity media and with an ion trap against poisoning.
  • Recording of operating data such as maximum temperature, hours under extreme conditions and CIP counter, which supports predictive maintenance.
  • Ex ia IIC certifications for ATEX, IECEx, CSA, NEPSI and others, and marine approvals from ABS, BV, DNV and LR.

Industrial Applications of the Endress+Hauser Memosens CPS11E

The Endress+Hauser Memosens CPS11E is used to monitor and control pH in neutralization stages, chemical dosing, flue gas scrubbers, boiler feedwater and cooling-water circuits, and in drinking water, well water and municipal or industrial wastewater plants. Because the sensor accepts hot and alkaline media with the application B glass and fluoride-bearing media with the application F glass, it also fits chemical processing. In Oman typical measuring points include desalination and reverse osmosis plants, power and district cooling stations, wastewater treatment and chemical plants in the Sohar and Salalah economic zones.

Seven Star LLC supplies the Memosens range throughout Oman and the GCC. Buyers can combine the sensor with the Endress+Hauser Liquiline CM442 or Liquiline M CM42 transmitter, or compare it with the ABB TB556 pH/ORP sensor for other designs.

Technical Specifications of the Endress+Hauser Memosens CPS11E

The table summarizes the main data of the Endress+Hauser Memosens CPS11E from Endress+Hauser Technical Information TI01493C.

Parameter Specification
Model Endress+Hauser Memosens CPS11E
Measured variables pH value and temperature (NTC 30K)
Measuring range, application A pH 1 to 12; –15 to +80 °C
Measuring range, application B pH 0 to 14; 0 to +135 °C
Measuring range, application F pH 0 to 10; 0 to +70 °C
Process pressure 0.8 to 17 bar abs. (A, B); 0.8 to 7 bar abs. (F)
Minimum conductivity 50 µS/cm (AA, TA); 0.1 µS/cm (AS, TS)
Installed length 120, 225, 360 or 425 mm; shaft Ø 12 mm
Process connection Pg 13.5
Materials Glass shaft, PTFE junction, PPS coupling, FKM O-ring
Degree of protection IP 68
Communication Memosens 2.0 digital, cable CYK10 or CYK20

Ordering a replacement CPS11E probe

Read the application code and insertion length from the existing sensor before selecting a replacement. The A, B and F versions have different pH and temperature limits. For low-conductivity water, include the minimum conductivity of the sample in the enquiry.

CPS11E manufacturer technical reference

Request a Quote for Endress+Hauser Memosens CPS11E

To order the Endress+Hauser Memosens CPS11E, send Seven Star LLC the medium, pH and temperature range, pressure, conductivity and the assembly and transmitter in use so that we can prepare a formal RFQ. The Technical Information TI01493C can be downloaded from this page, and our instrumentation division will confirm glass type, reference system and lead time. In Oman and the GCC, we supply the Endress+Hauser Memosens CPS11E with manufacturer documentation and local support.

Datasheets & Documents
  • PDF Datasheet Endress+Hauser Memosens CPS11E Technical Information (TI01493C) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser Memosens CPS11E Digital pH Sensor

Answers from our engineering team on installation, compatibility and integration.

01What is the Endress+Hauser Memosens CPS11E?
It is a digital pH sensor with Memosens 2.0 technology for standard applications in process technology, water and wastewater treatment, power plants and the chemical industry.
02What measuring ranges are available for the CPS11E?
Application A covers pH 1 to 12 at -15 to +80 °C, application B covers pH 0 to 14 at 0 to +135 °C, and application F covers pH 0 to 10 at 0 to +70 °C for hydrofluoric acid media.
03Which transmitters work with the Memosens CPS11E?
Memosens sensors must be connected to a transmitter with Memosens technology, such as the Liquiline CM42 or CM44x, using the Memosens cable CYK10 or CYK20.
04What pressure and installation limits apply to the CPS11E?
Applications A and B are rated 0.8 to 17 bar absolute and application F 0.8 to 7 bar absolute. The sensor must be installed at an angle of at least 15 degrees from the horizontal.
05Is Seven Star LLC a trusted supplier for Endress+Hauser products?
Yes. Seven Star LLC is a trusted supplier of Endress+Hauser products, supplying instrumentation across Oman and the GCC, with genuine documentation and local technical support.