Brand:

Yokogawa EJA120E-JES1C-U22EK Draft Range DP, Universal Flange

Description

Universal flange and stainless housing: EJA120E-JES1C-U22EK

Yokogawa EJA120E-JES1C-U22EK has three features that distinguish it from the other draft transmitters in the EJA120E family: an Rc1/4 female process connector, a universal flange orientation (code U) and an ASTM CF-8M stainless steel amplifier housing with an LCD that has a range-setting push button. The bolts are 660 SST, the bracket is a 316 SST L-type for vertical piping, and the output is HART.

Reading the suffix of EJA120E-JES1C-U22EK

Code position Meaning
-J 4 to 20 mA DC with HART 5 or HART 7 digital communication (selected at ordering)
E Capsule: 0.1 to 1 kPa span (0.4 to 4 inH2O)
S Wetted parts: ASTM CF-8M cover flange and connector, Hastelloy C-276 diaphragm, PTFE gasket, 316 SST vent/drain plug
1 Process connection: Rc1/4 female process connector
C Bolts and nuts: 660 SST
-U Installation: universal flange
2 Amplifier housing: ASTM CF-8M stainless steel
2 Electrical: 1/2 NPT female, two electrical connections, no blind plugs
E Integral indicator: digital indicator with range-setting push button
K Mounting bracket: 316 SST 2-inch pipe bracket, L type (vertical piping)

Universal flange

Installation code U denotes a universal flange. The other three installation codes describe a defined piping direction and high-pressure side: -7 vertical piping with the left side high and the process connection downside, -8 horizontal piping with the right side high, and -9 horizontal piping with the left side high. The universal flange is the fourth option and is selected when none of those fixed arrangements applies; check the flange drawing in the datasheet or ask us before relying on it for a particular piping layout.

Rating and data table

Item Value
Capsule E 0.1 to 1 kPa span
Connector Rc1/4 female
Bolts 660 SST
Installation U, universal flange
Housing ASTM CF-8M stainless steel, plus 1.5 kg
Electrical 1/2 NPT female x2
Indicator E, with push button
Bracket K, 316 SST L type, vertical piping
Output 4 to 20 mA, HART 5/7
Working pressure Minus 50 to 50 kPa
Temperature Minus 25 to 80 degrees C

Why stainless on a low-pressure instrument

Low pressure does not mean mild environment. Stacks, scrubbers and coastal installations expose a transmitter to acid dew point, salt and heat. The stainless housing, 660 SST bolting and 316 SST bracket address corrosion, adding 1.5 kg for the housing according to the datasheet. The vibration clause for housing code 2 is milder than for codes 1 and 3, so avoid mounting on vibrating ducts.

Weight and mounting

The basic transmitter weighs 3.7 kg; the stainless housing adds 1.5 kg. The L-type bracket suits a vertical 2-inch pipe, and the process Rc1/4 connectors are tapered female threads, so use compatible fittings.

Choose the flange orientation first, then connect the impulse lines, trim zero after final mounting, and set the range with the push button.

Housekeeping

Keep the draft taps clear, check for condensate in the lines and re-trim zero whenever the transmitter is moved. Because the unit is stainless, rinsing with fresh water after a wash-down or salt storm is safe; do not direct a high-pressure jet at the cover threads or the conduit entries. Review the transmitter self-diagnostic status at each planned shutdown and compare calibration records over time.

Electrical data and standards for EJA120E-JES1C-U22EK

Output is 4 to 20 mA DC with HART 5 or HART 7, linear or square root, range 3.6 to 21.6 mA, with 110 percent up-scale failure alarm as the default. Supply is 10.5 to 42 V DC for general use and flameproof types; HART communication requires at least 16.6 V DC at the terminals and 250 to 600 ohm of loop resistance. Damping is adjustable from 0 to 100 seconds. The datasheet quotes a 150 ms response time and a 45 ms update period. Housing protection is IP66/IP67 and Type 4X. Standards named in the datasheet include EN 61326-1 and EN 61010-1, the RoHS directive EN IEC 63000 and the PED 2014/68/EU with sound engineering practice for all capsules. SIL 2 capability applies in standard HART configuration.

Selection and ordering notes for EJA120E-JES1C-U22EK

Of the three draft-range codes offered here, this is the only one with the universal flange. The orientation therefore does not have to be decided before purchase, which suits spare stock held for several locations. Process connector code 1 gives Rc1/4 female ports, and other codes available are 0 (no connector, Rc1/4 female on the flanges), 2 (Rc1/2), 3 (1/4 NPT), 4 (1/2 NPT) and 5 (no connector, 1/4 NPT on the flanges). Slash options change the product, so mention any that appear on the nameplate, for example /HAC for plus or minus 0.09 percent accuracy.

Quick answers about EJA120E-JES1C-U22EK

  • What does U mean in the installation position? A universal flange, one of four installation choices for the EJA120E alongside -7, -8 and -9.
  • What housing does code 2 give? ASTM CF-8M stainless steel, which adds 1.5 kg.
  • What bolts are used? The bolts and nuts are 660 SST, selected by code C in the bolting position of the suffix.
  • What does the process connection 1 mean? A process connector with an Rc1/4 female thread is fitted on the cover flanges.
  • Does it have a local range switch? Yes, indicator code E adds a range-setting push button to the digital display.

Documents and quotation

Say whether you need the flange orientation noted for the site.

The datasheet for this model, Yokogawa GS 01C31B03-01EN, is attached as a PDF to the listing. In the RFQ please give the full part number EJA120E-JES1C-U22EK, quantity, tag numbers and the draft or low differential pressure you need to measure. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Stock status and lead time are confirmed per request.

Other Models in the EJA120E Range

Seven Star LLC supplies models from the EJA120E range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Yokogawa EJA120E-JES5J-912NB Draft Range DP TransmitterPressure TransmittersView details
Yokogawa EJA120E-DES4G-812DJ Draft Range DP, BRAINPressure TransmittersView details
Yokogawa EJA120E-JES1C-U22EK Draft Range DP, Universal FlangePressure TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Yokogawa EJA120E-JES1C-U22EK Draft Range DP, Universal Flange Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa EJA120E-JES1C-U22EK Draft Range DP,

Answers from our engineering team on installation, compatibility and integration.

01What does U mean in the installation position?
A universal flange, one of four installation choices for the EJA120E alongside -7, -8 and -9.
02What housing does code 2 give?
ASTM CF-8M stainless steel, which adds 1.5 kg.
03What bolts are used?
The bolts and nuts are 660 SST, selected by code C in the bolting position of the suffix.
04What does the process connection 1 mean?
A process connector with an Rc1/4 female thread is fitted on the cover flanges.
05Does it have a local range switch?
Yes, indicator code E adds a range-setting push button to the digital display.