Yokogawa EJA115E-JMS4J-912NB-N00NN0 Low Flow Transmitter
Description
A differential transmitter with its own orifice: EJA115E-JMS4J-912NB-N00NN0
Most flow loops need an orifice plate, two impulse lines, a manifold and a transmitter. Yokogawa EJA115E-JMS4J-912NB-N00NN0 collapses that into one body. The EJA115E is a differential pressure transmitter assembled with an integral orifice, intended for very low flow rates of liquids, gases and steam. This M-capsule version works with differential pressure spans of 2 to 100 kPa and gives a 4 to 20 mA HART signal proportional to flow when the square-root output mode is used.
The code JMS4J-912NB selects HART, the M capsule, stainless wetted parts, 1/2 NPT female connections, B7 bolting, horizontal piping with the high-pressure side on the left, an aluminum housing, 1/2 NPT conduit entries, no indicator and a 304 SST flat bracket for horizontal piping.
How to read EJA115E-JMS4J-912NB-N00NN0
| Code position | Meaning |
|---|---|
| -J | 4 to 20 mA DC with HART 5 or HART 7 digital communication (selected at ordering) |
| M | Capsule: span 2 to 100 kPa |
| S | Wetted parts: cover flange and process connector ASTM CF-8M, Hastelloy C-276 diaphragm, 316L SST others, PTFE orifice gasket |
| 4 | Process connection: 1/2 NPT female |
| J | Bolts and nuts: B7 carbon steel for cover flange and connector, 316L SST for manifold |
| -9 | Installation: horizontal piping, left side high pressure |
| 1 | Amplifier housing: cast aluminum alloy |
| 2 | Electrical: 1/2 NPT female, two electrical connections, no blind plugs |
| N | Integral indicator: none |
| B | Mounting bracket: 304 SST 2-inch pipe bracket, flat type (horizontal piping) |
| -N00NN0 | Fixed trailing code, always the same for this model |
Flow range of the M capsule
Because the orifice is built in, the flow range depends on the bore chosen when the unit is specified. The datasheet lists water-equivalent maximum flow ranges for the M capsule from 0.022 to 0.157 l/min at a 0.508 mm bore up to 3.3 to 23 l/min at a 6.350 mm bore, and air-equivalent ranges from 0.63 to 4.4 Nl/min up to 89 to 630 Nl/min. Intermediate bores of 0.864, 1.511, 2.527 and 4.039 mm fill in between. Orifice accuracy is plus or minus 5 percent of span under the conditions of the manufacturer technical information TI 01C20K00-01E.
Technical data for EJA115E-JMS4J-912NB-N00NN0
| Item | Value |
|---|---|
| Capsule M | Differential pressure span 2 to 100 kPa (200 to 10000 mmH2O) |
| Reference accuracy of transmitter | Plus or minus 0.055 percent of span for spans of 5 kPa or more |
| Integral orifice accuracy | Plus or minus 5 percent of span |
| Max working pressure | 16 MPa (2300 psi), all capsules |
| Burst pressure | 69 MPa (10,000 psi) |
| Response time | 90 ms (M and H capsules) |
| Update period | Differential pressure 45 ms; static pressure 360 ms |
| Process temperature | Minus 40 to 120 degrees C |
| Ambient | Minus 40 to 85 degrees C |
| Weight | 4.5 kg for M capsule, installation codes 7, 8 and 9, without indicator and bracket |
| Static pressure signal | Monitored via communication or indicator, minimum span 0.5 MPa |
Typical low-flow duties
Chemical dosing lines, small steam tracing supplies, sample conditioning loops, lube and seal-flush flows, and fuel gas to pilot burners all run at flows where a conventional orifice would need a tiny bore and long impulse lines. An integrated assembly keeps the bore close to the capsule. Because the transmitter also measures static pressure, the host can display line pressure without a second instrument.
Why the M capsule
The F capsule covers 1 to 5 kPa and the H capsule 20 to 210 kPa. The M capsule sits in the middle with a 2 to 100 kPa span and a 90 ms response time against 150 ms for F. It tolerates up to 16 MPa working pressure like the others. Ambient temperature effect for the M capsule is plus or minus (0.07 percent span plus 0.02 percent URL) per 28 degrees C, and its stability is plus or minus 0.1 percent of URL per 10 years.
Installation of EJA115E-JMS4J-912NB-N00NN0
Code -9 means horizontal piping with the left side as high pressure. The flat 304 SST bracket suits the horizontal orientation. Make sure the flow direction through the orifice agrees with the high-pressure side marking and that the process connection is sealed with 1/2 NPT-compatible paste. Vent and drain plugs of 316 SST sit on the cover flanges. Rotation in the diaphragm plane has no effect, but tilting 90 degrees shifts zero by up to 0.4 kPa, which can be trimmed.
Because the orifice is fixed, clogging is the main risk. Flush the line before removal and avoid mechanical cleaning of the micro bore. Check zero with both sides equalized.
Quick answers about EJA115E-JMS4J-912NB-N00NN0
- What does the EJA115E integral orifice do? It makes the differential pressure for flow measurement inside the transmitter assembly, so no separate orifice plate or impulse lines are required for very low flows.
- Which capsule does EJA115E-JMS4J-912NB-N00NN0 use? The M capsule, which gives a differential pressure span of 2 to 100 kPa.
- Does the part number include a display? No. The indicator position is N, so no digital indicator is fitted; the bracket is a 304 SST flat type.
- How accurate is the orifice? The datasheet quotes plus or minus 5 percent of span for the integral orifice under the conditions in TI 01C20K00-01E.
- What is the maximum pressure? Maximum working pressure is 16 MPa for all capsules, with a burst pressure of 69 MPa.
Documents and quotation
Please mention the process fluid, flow range and operating pressure so that the orifice bore can be confirmed.
Yokogawa general specification GS 01C31K01-01EN for the EJA115E low flow transmitter is supplied as the datasheet PDF with this listing. Send the full part number EJA115E-JMS4J-912NB-N00NN0, the quantity, the tag numbers and, because an integral orifice is calibrated to the flow case, the flow data or orifice bore you need. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Availability and lead time are confirmed per RFQ.
Other Models in the EJA115E Range
Seven Star LLC supplies models from the EJA115E range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Yokogawa EJA115E-JMS4J-912NB-N00NN0 Low Flow Transmitter | Pressure Transmitters | You are viewing this model |
| Yokogawa EJA115E-JFS4G-712EK-N00NN0 F Capsule Low Flow | Pressure Transmitters | View details |
| Yokogawa EJA115E-DHS2J-312DD-N00NN0 Low Flow BRAIN | Pressure Transmitters | View details |
Datasheets & Documents
- Datasheet Yokogawa EJA115E-JMS4J-912NB-N00NN0 Low Flow Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa EJA115E-JMS4J-912NB-N00NN0 Low Flow
Answers from our engineering team on installation, compatibility and integration.
01What does the EJA115E integral orifice do?
It makes the differential pressure for flow measurement inside the transmitter assembly, so no separate orifice plate or impulse lines are required for very low flows.
02Which capsule does EJA115E-JMS4J-912NB-N00NN0 use?
The M capsule, which gives a differential pressure span of 2 to 100 kPa.
03Does the part number include a display?
No. The indicator position is N, so no digital indicator is fitted; the bracket is a 304 SST flat type.
04How accurate is the orifice?
The datasheet quotes plus or minus 5 percent of span for the integral orifice under the conditions in TI 01C20K00-01E.
05What is the maximum pressure?
Maximum working pressure is 16 MPa for all capsules, with a burst pressure of 69 MPa.