Brand: SICK
SICK IM12-04BPS-ZW1 M12 Inductive Proximity Sensor, 4 mm Flush PNP
Description
SICK IM12-04BPS-ZW1 explained: the everyday M12 inductive sensor
The SICK IM12-04BPS-ZW1 (part no. 7900033) is a metric cylindrical inductive proximity sensor from the IM Standard series. It has an M12 x 1 thread, a nominal sensing distance Sn of 4 mm in flush installation, a PNP normally-open output and a 2 m PVC cable with three wires.
Such sensors are the workhorse of machine control: simple, sealed and free of moving parts. The datasheet confirms flush installation, a PNP normally-open output and a fixed cable, which together define where the IM12-04BPS-ZW1 can be used.
Installation designers like the IM12-04BPS-ZW1 because everything about it is predictable: a standard M12 x 1 thread with a 50 mm brass body, a 40 mm thread length that allows depth adjustment in a bracket, and two lock nuts that fix the position. A fixed cable removes the connector as a failure point in dirty areas, while the IP67 enclosure rating according to EN 60529 handles splash and dust.
IM12-04BPS-ZW1 feature summary
- Nickel-plated brass housing, 50 mm length and 40 mm thread length, plastic sensing face
- Switching frequency 1,000 Hz, hysteresis 1 percent to 15 percent
- Supply 10 V DC to 30 V DC, continuous current up to 200 mA, voltage drop up to 1.2 V
- Short-circuit and power-up pulse protection
- Operating temperature -25 to +70 degrees Celsius, IP67, shock and vibration 30 g, 11 ms and 10 to 55 Hz at 1 mm
- Maximum tightening torque 10 Nm
IM12-04BPS-ZW1 specification table
| Parameter | Value |
|---|---|
| Type part no. | 7900033 |
| Series | IM Standard, metric |
| Thread / diameter | M12 x 1 / 12 mm |
| Sensing range Sn | 4 mm, flush installation |
| Switching output | PNP, normally open, DC 3-wire |
| Supply voltage | 10 V DC to 30 V DC, ripple up to 10 percent |
| Voltage drop | Up to 1.2 V |
| Continuous current | Up to 200 mA |
| Switching frequency | 1,000 Hz |
| Hysteresis / reproducibility | 1 to 15 percent / up to 5 percent |
| Connection | Cable, 3-wire, 2 m, PVC, 0.22 mm square |
| Housing | Nickel-plated brass, 50 mm, thread length 40 mm |
| Sensing face | Plastic |
| Enclosure rating | IP67 |
| Operating temperature | -25 to +70 degrees Celsius |
| Maximum tightening torque | 10 Nm |
| MTTFD | 192 years |
Notable electrical numbers are the 100 ms time delay before availability after power-up, the temperature drift of up to plus or minus 10 percent of the real switching distance Sr and the EMC compliance according to EN 60947-5-2. These values help you calculate worst-case switching distances across the temperature range, an exercise that is often skipped and then blamed on the sensor.
The shock and vibration figure of 30 g for 11 ms and 10 to 55 Hz at 1 mm amplitude supports use on vibrating screens and compressor skids.
IM12-04BPS-ZW1 versus other IM12 types
Two close relatives exist with different connection types. The IM12-04BPS-ZWB (part no. 1017476) and IM12-04BPS-ZWK (part no. 6025682) share the 4 mm flush PNP normally-open rating but differ in how they connect, so check cable versus connector before ordering. Against the IME family, which uses a different electronic platform, the IM Standard line quotes reproducibility of up to 5 percent and a hysteresis range of 1 percent to 15 percent for this type, so applications that need very tight repeatability should be reviewed against the datasheet before an IM type is chosen.
Use of IM12-04BPS-ZW1 in Oman and the Gulf
Conveyor chain tracking, cylinder end-position detection, rotating shaft pulse counting on gearboxes and presence of metal parts on pallets are the day-to-day uses. In oil and gas packaged skids it is regularly specified as a valve position proxy, while in water treatment it detects pump-coupling rotation or gate position. The 4 mm flush range is long enough to leave a safe gap from vibrating machinery.
A further common use is chain and sprocket monitoring on bucket elevators in cement, gypsum and grain plants, where a broken chain must stop the drive quickly. Mounted at a 2 mm to 3 mm gap, the IM12-04BPS-ZW1 gives a pulse per tooth, and a simple speed relay turns the pulse train into an under-speed trip. The same arrangement works on fan shafts and mixer drives, giving maintenance teams a cheap condition signal long before a vibration monitor would trip. Typical gaps should be verified against the free-space dimensions, never assumed.
Choosing and installing IM12-04BPS-ZW1
For flush installation the datasheet lists free-space dimensions: A 6 mm, B 12 mm, C 12 mm, D 12 mm, E 2 mm and F 32 mm. Respect these to avoid mutual influence when several sensors are mounted side by side. Steel (St37) is the reference target; other metals reduce the distance, so plan a margin for aluminium or brass targets.
Reduction factors differ for non-ferrous metals. If the target is stainless steel, aluminium, brass or copper, expect a shorter switching distance than the 4 mm nominal value, and verify during commissioning with the real target rather than a test plate.
Wiring and testing of IM12-04BPS-ZW1
Connect the three conductors as shown in connection diagram CD-001 for the normally-open output: positive supply, 0 V and the switching output to the PLC input. Present a steel plate at 3 mm and confirm the output switches; then retract it to 5 mm and confirm it releases, observing the hysteresis.
Maintenance of IM12-04BPS-ZW1
Inductive sensors have no wear parts. Check that the lock nuts are tight, the cable is not squeezed and the sensing face is free of metal chips. The MTTFD is 192 years.
Supply of IM12-04BPS-ZW1
Order with type code IM12-04BPS-ZW1 and part number 7900033. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Documents and quotation
The datasheet for IM12-04BPS-ZW1 can be downloaded from this page. Send your RFQ with IM12-04BPS-ZW1, quantity and delivery location in Oman or the GCC.
Other Models in the Sick Im Standard Range
Seven Star LLC supplies models from the Sick Im Standard range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| SICK IM18-05BPS-ZC1 M18 Inductive Sensor, 5 mm Flush PNP, M12 Plug | Inductive Proximity Sensors | View details |
| SICK IM12-04BPS-ZW1 M12 Inductive Proximity Sensor, 4 mm Flush PNP | Inductive Proximity Sensors | You are viewing this model |
Datasheets & Documents
- Datasheet SICK IM12-04BPS-ZW1 M12 Inductive Proximity Sensor, 4 mm Flush PNP Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
SICK is the German maker of industrial sensors: photoelectric and proximity sensors, safety laser scanners and light curtains, encoders, distance sensors, code readers and gas analysers. Erwin Sick, an optics engineer, founded it in Munich in 1946, and in 1952 it introduced its first marketable accident-prevention light curtain, which protected press operators by stopping the machine when a hand broke the light beam. The company moved to Waldkirch in the Black Forest in 1956 and is still headquartered there. It is a privately held company, and has been an Aktiengesellschaft (AG) since 1996.
SICK company profile
| Founded | 1946, Munich, Germany, by Erwin Sick (1909–1988) |
|---|---|
| Headquarters | Waldkirch, Baden-Württemberg, Germany (since 1956) |
| Ownership | Privately held; after the founder's death in 1988 his widow Gisela Sick became the main shareholder. Legal form SICK AG since 1996 |
| Size | More than 12,000 employees and group revenue of about EUR 2.3 billion (company figures for 2023) |
| First breakthrough | Accident-prevention light curtain for presses, shown in Hanover in 1952 |
| International growth | First foreign subsidiary in France in 1972, United States in 1976; today sales and service companies worldwide |
| Product families | Photoelectric, inductive, capacitive, magnetic and ultrasonic sensors; safety laser scanners, light curtains, safety controllers and relays; encoders and motor feedback systems; distance sensors and LiDAR; barcode and 2D code readers and machine vision; gas analysers, dust and flow measurement for process and emissions monitoring |
Milestones
- 1946: Erwin Sick receives a licence to run his engineering firm in Munich.
- 1952: The first marketable accident-prevention light curtain is presented in Hanover and goes into series production.
- 1956: The company moves to Waldkirch with 25 employees.
- 1972 and 1976: Subsidiaries are founded in France and the United States.
- 1996: SICK becomes an Aktiengesellschaft.
- Today: Sensors for factory and logistics automation, machine safety and process analysis, with a large share of revenue outside Germany.
Choosing a SICK sensor
For object detection, the sensing principle comes first. A retro-reflective sensor (WL series) sends light to a reflector and switches when an object breaks the beam; it is reliable over long distances and easy to align. A sensor with background suppression (WTB series) detects an object at a set distance and ignores what is behind it, which suits conveyors with shiny or dark backgrounds. A through-beam pair (WS/WE) gives the longest range and the highest reliability in dust. For transparent bottles and film, use a model built for transparent objects (for example WL12G-3B or WL150-P420). The digits in the code also matter: "P" usually means a PNP output and "N" NPN, and the last digits set the connector or cable. For machine guarding, a safety laser scanner such as nanoScan3 or microScan3 protects an area, while a safety controller such as Flexi Soft combines several safety devices.
Where SICK products are used
In Oman and the GCC, SICK sensors are used in packaging and bottling lines, food and beverage plants, logistics and airport baggage handling, cement and steel plants, ports and cranes, automated warehouses, and on machines built by European OEMs. SICK safety scanners guard robots and automated guided vehicles, and its encoders give position feedback on motors, hoists and conveyors.
SICK products we list
| Family | Examples |
|---|---|
| Photoelectric sensors | WL12-3P2431, WTB12-3P2431, GTB6-P4211, VL18-4P3240, WL12G-3B2531, WS/WE100, KT5W contrast, W26 IO-Link |
| Proximity, cylinder and ultrasonic sensors | IME12-08NPSZC0S, IME18-05BPSZC0S, MZT8, UM18 4-20 mA, UM30, UFN3 fork |
| Machine safety | nanoScan3, microScan3, S300 Professional, Flexi Soft FX3-CPU1, FX3-XTIO, ReLy OSSD |
| Encoders and motor feedback | DFS60B, AFM60 PROFINET, AFS60 SSI, ATM60 PROFIBUS, SRS50, EFS50 |
| Distance sensors and code readers | DT50, DL50, DT35, Lector632 |
Ordering SICK products: what we need
Send the type code and the 7-digit SICK part number from the label (for example WTB12-3P2431 together with its part number). For a replacement sensor, add the output (PNP or NPN), connection (M8, M12 or cable) and sensing distance. For encoders, add the interface (incremental, SSI, PROFIBUS, PROFINET), resolution and shaft type. For safety scanners, tell us the model and whether the existing configuration needs to be kept.
Frequently requested SICK models: SICK WTB4-3 Miniature Photoelectric Proximity Sensor, SICK IME18-08NPSZW2K Inductive Proximity Sensor, SICK DT35-B15251 Laser Distance Sensor, SICK microScan3 Safety Laser Scanner, SICK RZT7-03ZUS-KWB T-Slot Cylinder Sensor.
Facts checked against SICK's published company history and annual figures, October 2026.
Browse SICK products by category: Sensors & Transmitters.
FAQ
Questions about the SICK IM12-04BPS-ZW1 M12 Inductive Proximity Sensor,
Answers from our engineering team on installation, compatibility and integration.
01What is the sensing distance of SICK IM12-04BPS-ZW1?
Sn is 4 mm in flush installation, as stated in the manufacturer datasheet for IM12-04BPS-ZW1.
02What output does IM12-04BPS-ZW1 have?
PNP normally open on a three-wire DC connection.
03How is IM12-04BPS-ZW1 connected?
Via a fixed three-wire PVC cable of 2 m with 0.22 mm square conductors.
04What is the maximum tightening torque of IM12-04BPS-ZW1?
10 Nm on the M12 x 1 brass housing, as stated in the manufacturer datasheet for IM12-04BPS-ZW1.
05What switching frequency does IM12-04BPS-ZW1 offer?
1,000 Hz with 10 V to 30 V DC supply, as stated in the manufacturer datasheet for IM12-04BPS-ZW1.


















Reviews