- Automation & ControlView all 1,920 products
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- HMI Displays
- Industrial Computers
- Motor Soft Starters
- Servo Drives
- Pneumatic Cylinders
- Machine Vision
- Automation Software
- Robotics
Brand: Lovato Electric
Lovato VLB30040A480 AC Drive 4 kW, 400-480 V, C2 EMC Filter
Description
Lovato VLB30040A480 variable speed drive, 4 kW, 400-480 V
The Lovato VLB30040A480 is a three-phase variable speed drive for 400 to 480 V AC supplies with a rated output current of 9.5 A, equal to 4 kW at heavy load or 5 HP, and 7.5 HP at standard load. It has a built-in category C2 EMC filter, a brake chopper, RS485 Modbus-RTU and a multi-pump PID function. Seven Star LLC supplies the VLB30040A480 in Oman and the GCC as an independent supplier in Muscat.
The code gives the series VLB3, the power 0040 meaning 4.0 kW, and A480 for the 480 V class. The catalogue lists VLB30015A480, VLB30022A480, VLB30040A480, VLB30055A480 and others in the same series, so the number identifies the rating.
VLB30040A480 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Lovato / VLB30040A480 |
| Supply | Three-phase 400 to 480 V AC (340 to 528 V), 50/60 Hz (45 to 65 Hz) |
| Output | Three-phase 0 to 480 V, 0 to 599 Hz |
| Rated output current | 9.5 A |
| Power | 4 kW; 5 HP heavy load / 7.5 HP standard load |
| Input current | 12.5 A heavy / 14 A standard load without choke; 9 / 11 A with choke |
| Overload | 150% for 60 s; 200% for 3 s |
| Switching frequency | 2 to 16 kHz |
| EMC filter | Built-in, category C2 |
| Brake chopper | Yes |
| Motor cable length, shielded | 50 m / 100 m; C1 3 m; C2 20 m; C3 35 m; unshielded 200 m |
| Communication | RS485 Modbus-RTU |
| Digital I/O | 5 inputs PNP/NPN; 1 changeover relay 3 A 250 V AC + 1 digital output 100 mA |
| Analog I/O | 2 inputs (0/2-10 V, -10 to +10 V, 0-5 V, 0/4-20 mA); 1 output |
| STO safety | Optional |
| Temperature | -10 to +55 °C; derating 2.5%/°C above 45 °C (2 or 4 kHz) |
| Altitude | 4000 m; derate 5%/1000 m above 1000 m |
| Protection / size | IP20; 90 x 278 x 130 mm; 2.45 kg |
Heavy and standard load ratings for the VLB30040A480
The nameplate figure of 4 kW applies to heavy-load duty with 150 percent overload for 60 seconds, which suits conveyors, mixers and compressors. For standard-load duty, with lighter overload such as fans and centrifugal pumps, the same hardware is rated 7.5 HP. In practice, size the drive by motor current: 9.5 A for this unit, then check overload requirements. The 12.5 and 14 A input currents drop to 9 and 11 A with a mains choke, which also reduces harmonics.
Control modes and functions
Control modes include V/f linear and quadratic, multipoint V/f, sensorless vector, torque setpoint and closed-loop options with encoder feedback, which makes the drive flexible from simple fans to demanding hoists. Fifteen preset speeds, S-shaped ramps, slip compensation, flying restart, DC braking, a sequencer and a PID controller with sleep and rinse function are included, along with multi-pump control that runs one speed-regulated pump and two direct-start auxiliary pumps. A PTC probe input protects the motor, and the drive trips on overcurrent, short circuit, overvoltage, undervoltage, phase loss and motor overload.
Where the VLB30040A480 fits
The drive sits between the incoming supply, with fuses or a breaker such as the SM1P range upstream protection, and the motor. For hoists or fast decelerating loads, a braking resistor can be connected to the chopper. In multi-pump booster sets the drive plus two contactors, for example from the BF range, form a complete pressure control system.
VLB30040A480 selection and ordering checklist
- Motor nameplate current against 9.5 A and duty type
- Supply voltage 400 to 480 V three-phase
- Motor cable length against the EMC category needed
- Need for braking resistor, mains choke or STO option
- Control interface: analogue, digital or Modbus
- Ambient temperature and altitude derating
Installation and commissioning of the VLB30040A480
Mount vertically with clearance for airflow, and use shielded motor cable of limited length for the EMC class chosen. Enter the motor nameplate data, select the control mode and run the autotuning if applicable; the data sheet marks autotuning as not available, so set the motor parameters manually. Check the direction of rotation before coupling a load, and set ramps long enough to avoid overcurrent trips.
Typical VLB30040A480 applications in Oman and the GCC
Typical loads are chilled-water and booster pumps, ventilation fans, conveyors and mixers. At 4 kW the drive is IP20 and must be installed in a cabinet; in hot Gulf panels, derate above 45 °C.
Cable length, EMC and derating of the VLB30040A480
The built-in C2 filter is effective only with shielded motor cable up to 20 m according to the table; at 3 m the drive meets category C1, and at 35 m only category C3. Beyond 50 m of shielded cable, or 200 m unshielded, the drive requires an output filter, and the 100 m figure applies only below 40 °C ambient and 4 kHz switching. Where the motor is far from the drive, as on a borehole pump, plan an output reactor early in the design.
Temperature derating is 2.5 percent per degree above 45 °C at 2 or 4 kHz switching and above 40 °C at 8 or 16 kHz, so a lower carrier frequency is the first remedy in a hot panel, at the cost of more motor noise. Above 1000 m altitude the rated current drops by 5 percent per 1000 m. Check these curves for desert and mountain sites.
Information to send with an RFQ for the VLB30040A480
- Part number VLB30040A480 and quantity
- Motor kW, current and voltage
- Load type and overload requirement
- Control and communication interface
- Cable length and EMC requirement
- Delivery location
Site conditions in Oman for the VLB30040A480
Low-voltage switching and protection devices in Oman often sit in motor control centres and outdoor panels where internal temperatures are high for much of the year. When you select the VLB30040A480, check its rated values at your real ambient temperature, as stated in the manufacturer documentation, and confirm the coordination with upstream protection and with the motor or load it serves. Short-circuit levels differ from site to site, so verify the breaking capacity required at the point of installation.
Standardising ratings and coil voltages across a project reduces the number of spare part numbers that need to be stocked. Keeping a small stock of the VLB30040A480 and recording settings such as trip ranges or ramp times shortens repair work during a breakdown.
Documents and quotation
Send the part number VLB30040A480 and we will confirm the documents available for it, such as the technical data sheet, wiring diagram and instruction sheet, together with availability and lead time.
Seven Star LLC is an independent supplier in Muscat and is not an official channel of the manufacturer. Share the quantity, delivery location and project reference with the request and we will answer with a formal quotation.
Reviews (0)
How would you rate this product? Cancel reply
About brand
Lovato Electric is the Italian manufacturer of low-voltage electrical components for industrial automation and power distribution: contactors, motor protection circuit breakers, soft starters, variable speed drives, power factor controllers, transfer switch and generator controllers, and energy meters. It was founded in Bergamo in 1922 and has been run by the same family for four generations. Its headquarters is in Gorle, near Bergamo, and it celebrated its centenary in 2022.
Seven Star LLC is an independent supplier in Muscat. We list Lovato motor control, drives and power management products, and supply them to panel builders, contractors and maintenance teams in Oman and the GCC by order code.
Lovato Electric at a glance
| Established | 1922, Bergamo, Italy |
|---|---|
| Headquarters | Gorle (Bergamo), Italy |
| Ownership | Private, family-run for four generations |
| Product families | Contactors and relays, motor protection circuit breakers, motor starters, soft starters, variable speed drives, power factor controllers, ATS and gen-set controllers, multimeters and energy meters, micro PLCs |
Lovato products we list
| Family | Models | Typical use |
|---|---|---|
| Contactors | BF0910A230, BF1810A230, BF2510A230, BF2600A230, BF09T4A230 4-pole, BFS0923A024, 11BG0910A230 mini, 11BGR0901A048 reversing | Switching motors, heaters, lighting and capacitor banks |
| Motor protection and starters | SM1P0650, SM1P1000, SM1P3200, M1P enclosed DOL starter, ME024FD024, ME070RSD024, 31L48 time relay | Short-circuit and overload protection and direct starting of motors |
| Soft starters | ADXL0030600, ADXL0085600, ADXL0135600, ADXT0034, ADXT0084, ADXT0139 | Reducing starting current and mechanical shock on pumps, fans and compressors |
| Variable speed drives | VLA1, VLB1, VLB3 0.75 kW, VLB3 2.2 kW, VLB3 5.5 kW, VLB3 22 kW, VT1 | Speed control of pumps, fans and conveyors to save energy |
| Power management and control | DCRG8, DCRL8 PF controllers, ATL600 ATS controller, RGK600 gen-set controller, DMG200 multimeter, DMED300T2 energy meter, LRD20 micro PLC | Power factor correction, mains/generator changeover and energy monitoring |
Lovato order codes describe the product. On a contactor such as BF0910A230, "BF09" is the frame and rated current (9 A in AC-3), "10" is the built-in auxiliary contact (one normally open), "A" means an AC coil and "230" is the coil voltage. The coil voltage must match the control circuit exactly, so it is the most common detail to check when replacing one. For motors, a soft starter limits the inrush current at start and stop, while a variable speed drive controls the speed continuously and saves energy on pumps and fans that do not need full flow all the time.
Where Lovato products are used
In Oman and the GCC, Lovato components are built into motor control centres, pump and HVAC panels, capacitor banks for power factor correction, generator and ATS panels, and machine control panels for industry, water and buildings.
Ordering Lovato products: what we need
Send the full Lovato order code. For contactors and starters, confirm the coil or control voltage. For drives and soft starters, send the motor power, current and supply voltage. For power factor controllers, send the number of steps and the CT ratio.
Facts checked against Lovato Electric company profile brochures, October 2026.
Browse Lovato Electric products by category: Motor Soft Starters, Automation Accessories, Controllers & Data Acquisition, PLC & I/O Cards, Circuit Breakers, Diesel Generator Spare Parts.
FAQ
Questions about the Lovato VLB30040A480 AC Drive 4 kW, 400-480 V, C2
Answers from our engineering team on installation, compatibility and integration.
01What is the rated output current of the VLB30040A480?
9.5 A, equal to 4 kW at heavy load or 5 HP, and 7.5 HP at standard load.
02Does the VLB30040A480 have an EMC filter?
Yes, a built-in category C2 filter.
03Does it have a brake chopper?
Yes, a brake chopper is built in.
04What communication does it have?
RS485 with Modbus-RTU.
05What supply voltage does it need?
Three-phase 400 to 480 V AC, with an operating range of 340 to 528 V.


















Reviews
There are no reviews yet.