- Automation & ControlView all 3,026 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: ION Science
ION Science Falco 2 Fixed VOC Gas Detector (PID)
Description
Overview
The ION Science Falco 2 is a fixed VOC gas detector designed to stay on a wall, a pipe rack or a fence line and report volatile organic compound levels around the clock. Seven Star LLC is an independent supplier serving Oman and the GCC. The brochure for the Falco 2, version 1.2, describes a flameproof housing wrapped around a photoionisation sensor that is protected from condensing moisture, which makes the unit suitable for wet outdoor positions where ordinary PID heads would suffer. The notes below summarise that brochure for plant engineers evaluating a continuous VOC monitor.
Many gas detectors fixed on a plant are looking for a single flammable gas at percent-of-LEL levels. The ION Science Falco 2 is different because it works at parts per million and below, so it can flag a small solvent or aromatic release long before a flammable limit is approached. That is useful for exposure monitoring, environmental control and early leak detection around storage and process areas.
Sensing technology inside the ION Science Falco 2
The sensor is a photoionisation detector based on the MiniPID 2, with a choice of 10.6 eV or 10.0 eV lamp. The brochure highlights three protective features. Patented fence electrode technology and an anti-contamination design resist humidity, dust and particulates. Typhoon technology prevents condensation from forming inside the PID sensor, which the manufacturer says eliminates false readings seen with competing technology. The design is stated to operate across 0 to 100 percent relative humidity, including condensing conditions.
With the 10.6 eV lamp the detector offers four predefined measurement ranges: 0.001 to 10 ppm, 0.01 to 50 ppm, 0.1 to 1000 ppm and 0 to 3000 ppm. With the 10.0 eV lamp the range is 0.01 to 50 ppm, tuned for total aromatic compounds such as benzene, xylene and toluene. Both pumped and diffused sampling versions are available.
Technical data table for ION Science Falco 2
| Parameter | Published value |
|---|---|
| Sensor | Photoionisation detector, 10.6 eV or 10.0 eV lamp |
| Ranges with 10.6 eV lamp | 10 ppm (0.001 resolution), 50 ppm (0.01), 1000 ppm (0.1), 3000 ppm (1) |
| Range with 10.0 eV lamp | 50 ppm with 0.01 ppm resolution |
| Response T90 | Pumped under 10 seconds; diffused under 30 seconds |
| Accuracy | Plus or minus 5 percent or plus or minus 1 digit |
| Outputs | 4 to 20 mA, two programmable relays, RS485 Modbus |
| Supply | 8 to 40 Vdc, typically 2 W, maximum 7 W |
| Display | 35 x 17.5 mm OLED, 128 x 64 pixels, five magnetic switches |
| Status indicator | Red, amber, green, visible from 20 metres in direct sunlight |
| Cable entries | Two M25, left and right; mounting points two M8 |
| Temperature, pumped | -20 to +50 degrees C operation, 0 to 100 percent RH including condensing |
| Temperature, diffused | -40 to +50 degrees C operation |
| Protection | IP65 for main unit and sensor head |
| Dimensions and mass | Pumped 325 x 192 x 115 mm, 2.9 kg; diffused 223 x 192 x 115 mm, 2.5 kg |
| Certification | II 2G, Ex db ib IIC T4 Gb (ATEX and IECEx); Class I Zone 1 AEx db ib IIC T4 Gb |
| Warranty | 12 months standard, 24 months extended |
How Falco 2 differs from other fixed ION Science VOC detectors
The older TVOC 2 is a diffusive 3-wire detector with a 4 to 20 mA output only, user-selectable ranges up to 1000 ppm and a 7 segment LCD, drawing 5 to 28 Vdc. The ION Science Falco 2 adds Modbus RS485 and two programmable relays, an OLED display with magnetic switch interface, a flameproof Ex db ib housing for Zone 1, and the Typhoon moisture protection. It also offers a pumped variant with a built-in pump and luer connection capable of sampling from 20 metres, depending on tubing diameters, which the TVOC 2 does not.
Where the Falco 2 fits in Gulf facilities
The brochure lists solvent and chemical storage, lithium-ion battery manufacturing and storage, TAC monitoring in refineries, air quality monitoring, in-situ process monitoring and leak detection. In Oman this covers chemical warehouses, bulk liquid terminals, process units in the industrial estates of Sohar and Salalah, and waste or water treatment plants where VOC emissions are regulated. The wide humidity tolerance matters in coastal locations where dew and salt-laden air are routine.
Installation and commissioning of ION Science Falco 2
Mount the unit on its two M8 points at a height appropriate to the vapour density of the target compounds, route cable through the M25 entries using suitable glands, and connect the 4 to 20 mA loop, relay contacts and Modbus lines to the control system. Because the housing is dual certified, the sensor can be serviced with the aid of the intrinsically safe sensor section, and the tamper-proof magnetic switches let a technician operate the menu without opening the enclosure. Calibrate with isobutylene at the span and confirm relay setpoints during commissioning.
Signals, control integration and alarms
The status indicator cycles between green for normal, amber for a warning and red for an alarm condition, and it can be read from 20 metres in direct sunlight. The two programmable relays are useful for starting an extraction fan, closing a valve or sounding a local horn without waiting for the control system, while the 4 to 20 mA loop and Modbus link give the supervisory system both a trend and diagnostics. Engineers often use the relays for the first alarm level and let the control room decide the second action from the analogue value.
Because the dual certification allows a technician to service the sensor section while the electronics remain protected, routine lamp and filter service does not need the lengthy hot work procedures required for some other fixed heads. Plan the first calibration soon after installation and keep a log, which helps demonstrate compliance during audits and incident reviews.
Maintenance of the Falco 2
Inspect the sampling inlet and filters on a regular schedule, since dust and particles reduce flow in pumped versions. Clean or replace the lamp following the manual when the reading becomes unstable. Schedule periodic calibration and bump checks under your site gas detection plan, and record the results. The multi-colour status indicator allows a quick visual check on rounds without a handheld device.
Selection checklist for Falco 2
Choose the lamp by target compound, choose pumped or diffused sampling by installation distance and response need, and confirm the supply voltage and output requirements. Please confirm the exact variant on the nameplate if you are replacing an installed detector.
Related items you may also need: ION Science Titan 2 Fixed Benzene Monitor | ION Science Tiger XT Handheld VOC Detector | Crowcon SMART 3G-D2 SIL 2 Fixed Gas Detector with Display | All ION Science products.
Choosing the right ION Science Falco 2 kit
The ION Science Falco 2 is offered as a model with several kit and accessory options, so the exact supply is defined by the points below rather than by the model name alone.
- Target gas or gases and the measuring range needed for the ION Science Falco 2 application.
- Lamp or sensor option where the instrument offers more than one, for example the standard VOC lamp or a selective configuration.
- Hazardous area approval required for the site, such as ATEX or IECEx zone rating.
- Accessories needed with the unit, such as charger, calibration adaptor, sampling probe, carry case or docking station.
- Any data logging, software or calibration certificate requirement for your records.
Share these points, or the part number printed on an existing unit or previous order, and the quotation will list the confirmed kit contents.
Documents and quotation
The manufacturer’s Falco 2 brochure is attached to this page as a datasheet. Send your RFQ with the part number Falco 2, the lamp and sampling variant, quantity and delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet ION Science Falco 2 Fixed VOC Gas Detector (PID) Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ION Science is a British maker of gas detection instruments, based in Fowlmere, Cambridgeshire. It has been active since 1989 and is best known for photoionisation detectors (PIDs) that measure volatile organic compounds at low concentrations. Its portable and fixed instruments are used for worker exposure monitoring, leak detection and environmental surveys.
Seven Star LLC is an independent supplier in Muscat. We list ION Science detectors for oil and gas, petrochemical and environmental users in Oman and the GCC.
ION Science company profile
| Active since | 1989, United Kingdom |
|---|---|
| Head office | Fowlmere, Cambridgeshire |
| Core technology | Photoionisation detection (PID) with patented Fence Electrode design |
| Product families | Tiger XT and Cub portable PIDs, Titan benzene monitor, Falco fixed detectors |
Milestones
- 1989: ION Science begins operating.
- 1998: Patents its PID sensor.
- 2002: Patents the Fence Electrode for humidity-resistant PIDs.
- 2017: Opens its head office in Fowlmere.
ION Science product series
The Tiger XT is a handheld VOC detector for hazardous areas, and the Titan 2 is a fixed benzene monitor.
A PID uses ultraviolet light to ionise volatile organic compounds and measures the resulting current, which allows detection down to ppb levels. Response factors convert the reading for each specific compound. General VOC detectors measure the total, while benzene-specific monitors separate benzene from other hydrocarbons, which matters because benzene has very low exposure limits.
Where ION Science detectors are used
Leak detection, confined space entry checks, worker exposure monitoring, refinery and terminal benzene monitoring, and environmental and soil surveys.
Ordering ION Science detectors: what we need
Send the model, the compounds and ranges, lamp type, hazardous-area requirement and accessories such as probes, filters and calibration kits.
Facts checked against ION Science's published company history, October 2026.
Browse ION Science products by category: Gas Analyzer Systems, Fire & Gas Detectors.
FAQ
Questions about the ION Science Falco 2 Fixed VOC Gas Detector (PID)
Answers from our engineering team on installation, compatibility and integration.
01What outputs does the ION Science Falco 2 provide?
It provides a 4 to 20 mA analogue output, RS485 Modbus digital communication and two programmable relays for normally open or normally closed contacts.
02What ranges does the ION Science Falco 2 offer?
With the 10.6 eV lamp: 0.001-10, 0.01-50, 0.1-1000 and 0-3000 ppm; with the 10.0 eV lamp: 0.01-50 ppm for aromatic compounds.
03Is the Falco 2 suitable for wet outdoor locations?
Yes. Typhoon technology prevents condensation inside the PID sensor and the unit is rated IP65 for 0 to 100 percent relative humidity including condensing.
04What is the certification of the Falco 2?
It is marked II 2G Ex db ib IIC T4 Gb under ATEX and IECEx, with a North American Class I Zone 1 AEx db ib IIC T4 Gb marking.
05How far can the pumped Falco 2 sample?
The built-in pump with luer connection can sample from up to 20 metres, depending on the inner and outer diameter of the tubing.


















Reviews
There are no reviews yet.