- Automation & ControlView all 1,962 products
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Automation Accessories
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- HMI Displays
- Motor Soft Starters
- Industrial Computers
- Servo Drives
- Pneumatic Cylinders
- Machine Vision
- Automation Software
- Robotics
Brand: Hanna Instruments
Hanna HI98194 Multiparameter Waterproof Meter pH EC DO
Description
Hanna HI98194 multiparameter waterproof meter with DO, EC, pH and pressure
The Hanna HI98194 is a rugged handheld multiparameter instrument that reads pH, ORP, conductivity, TDS, resistivity, salinity, seawater sigma, dissolved oxygen, atmospheric pressure and temperature from one multisensor probe. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
The model number belongs to the HI9819x family: the HI98194 carries all three probe sensor slots (pH/ORP, galvanic DO and four-ring EC), while the HI98195 drops the DO sensor and the HI98196 drops conductivity. The probe is the matching HI7698194, and the meter only works with the probe version of its own number.
HI98194 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Hanna Instruments HI98194 |
| Dissolved oxygen | 0.0 to 500.0 % and 0.00 to 50.00 mg/L; resolution 0.1 % / 0.01 mg/L; accuracy ±1.5 % of reading or ±1.0 % up to 300 %, ±3 % of reading above 300 % |
| Temperature | -5.00 to 55.00 °C; resolution 0.01 °C; accuracy ±0.15 °C |
| pH / mV | 0.00 to 14.00 pH, ±600.0 mV; resolution 0.01 pH; accuracy ±0.02 pH, ±0.5 mV |
| ORP | ±2000.0 mV; resolution 0.1 mV; accuracy ±1.0 mV |
| Conductivity | 0 to 200 mS/cm (absolute EC to 400 mS/cm); accuracy ±1 % of reading or ±1 µS/cm, whichever is greater |
| TDS | 0 to 400,000 mg/L (maximum depends on TDS factor); accuracy ±1 % of reading or ±1 mg/L |
| Resistivity | 0 to 999,999 Ω·cm; 0 to 1.0000 MΩ·cm |
| Salinity | 0.00 to 70.00 PSU; accuracy ±2 % of reading or ±0.01 PSU |
| Seawater sigma | 0.0 to 50.0 σt, σ0, σ15; accuracy ±1.0 |
| Atmospheric pressure | 450.0 to 850.0 mmHg (600.0 to 1133.2 mbar); accuracy ±3.0 mmHg within ±15 °C of calibration temperature |
| Logging | 45,000 records in up to 100 lots; interval 1 second to 3 hours; USB to PC |
| Protection | IP67 meter; IP68 probe; probe rated to 20 m depth |
| Power / size | Four 1.5 V AA alkaline cells, about 360 hours without backlight; 185 × 93 × 35.2 mm, about 400 g |
| Sample environment | Fresh, brackish and seawater |
| Warranty | Two years |
How the HI98194 works
The multisensor probe carries up to three replaceable sensors in a single body: a combination pH/ORP sensor (glass bulb, platinum ORP element and double-junction Ag/AgCl reference with gel electrolyte), a galvanic dissolved oxygen sensor with a gas-permeable membrane, and a four-ring conductivity sensor that resists polarisation and surface coating. Oxygen passing through the membrane is reduced at the cathode, and the resulting current gives the concentration; the DO sensor conforms to Standard Methods 4500-O G and EPA 360.1 as stated in the manual.
Conductivity feeds the derived values: TDS, resistivity, salinity and seawater sigma all follow from the EC or salinity calibration. The meter compensates temperature automatically between -5 and 55 °C, and it uses the on-board barometer for DO correction, so an atmospheric pressure calibration should be done when conditions change.
Where HI98194 fits: sensors, accessories and related models
The HI98194 pairs with the HI7698194 probe, available with 4 m or 10 m cable (HI7698194/4 and HI7698194/10). Replacement parts are ordered by sensor code: HI7698194-0 pH, HI7698194-1 pH/ORP, HI7698194-2 DO and HI7698194-3 EC. A probe maintenance kit holds DO electrolyte, membrane caps and O-rings.
Data goes to a PC through USB with the HI9298194 software, and the meter stores up to 45,000 records. Sibling models in the family include the HI98195 and HI98196, shown below.
HI98194 family comparison
| Model | Measurements | Probe | Sensor inputs |
|---|---|---|---|
| HI98194 | pH/mV, ORP, EC, TDS, resistivity, salinity, seawater sigma, DO, pressure, temperature | HI7698194 | 3 |
| HI98195 | pH/mV, ORP, EC, TDS, resistivity, salinity, seawater sigma, pressure, temperature | HI7698195 | 2 |
| HI98196 | pH/mV, ORP, DO, pressure, temperature | HI7698196 | 2 |
Choose the HI98194 when a single deployment must give water chemistry and DO together, for example brine discharge studies or intake monitoring. If dissolved oxygen is not needed, the HI98195 reduces probe cost and maintenance of the DO membrane.
Selection and ordering checklist for HI98194
- Confirm the parameters needed: DO plus EC plus pH/ORP all in one probe points to HI98194
- Choose cable length, 4 m or 10 m, for the deployment depth (rated to 20 m)
- Decide whether spare sensors and the probe maintenance kit should be quoted with the meter
- Check the calibration solutions in use: pH buffers 4.01, 6.86, 7.01, 9.18 and 10.01, and EC standards such as 1413 µS/cm
- Confirm PC software and USB cable requirements for data export
Installation, calibration and maintenance of HI98194
New sensors must be conditioned: pH sensors soak in storage solution (HI70300) for at least half an hour, the ORP element needs surface cleaning, and the galvanic DO sensor is activated before installation per the manual. Calibrate pH at one to three points with automatic buffer recognition, EC at one point with six preset standards, DO at 0 and 100 % or a custom point, and atmospheric pressure at one custom point.
Replace DO membranes on schedule, rinse the probe with deionised water after brackish or oily samples, and store with the guard in place. Do not exceed the 20 m rating and anchor the cable rather than letting it carry load; the cable is rated for 68 kg intermittent pull.
Typical applications of HI98194 in Oman and the GCC
Environmental consultants and plant operators across Oman use this class of meter for wadi, lagoon and coastal surveys, brine and cooling-water discharge compliance, aquaculture ponds and treated sewage effluent. The salinity and seawater sigma outputs are directly relevant to desalination intake and outfall studies on the Gulf of Oman and Arabian Sea coasts, and the IP67/IP68 build copes with spray, dust and sun on field days.
Information to send with an RFQ for HI98194
- Quantity and cable length (4 m or 10 m probe)
- Required spares: pH/ORP, DO and EC sensors, probe maintenance kit
- Calibration solutions needed (pH buffers, EC standards, DO zero solution)
- Delivery location and lead time
- Project or tender reference
Documents and quotation
The instruction manual for the HI98194 is attached on this page for specifications, calibration procedures and maintenance steps.
Send the part number HI98194, the quantity and your delivery location and we will reply with availability and a quotation.
Datasheets & Documents
- Manual Hanna HI98194 Instruction Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Hanna Instruments is a maker of analytical instruments for water and liquid testing, founded in 1978 in the Padua area of Italy by Oscar and Anna Nardo. Its early breakthrough was the pHep, an affordable pocket-sized pH tester. The company is now led by the founders' children, Martino and Pamela Nardo, with its headquarters in Woonsocket, Rhode Island, and offers more than 3,000 products.
Seven Star LLC is an independent supplier in Muscat. We list Hanna instruments for water, wastewater and laboratory users in Oman and the GCC.
Hanna Instruments company profile
| Founded | 1978, near Padua, Italy, by Oscar and Anna Nardo |
|---|---|
| Headquarters | Woonsocket, Rhode Island, USA |
| Leadership | Martino Nardo and Pamela Nardo |
| Early product | The pHep pocket pH tester |
| Product families | pHep and HI98 waterproof testers, edge benchtop meters, HI83 multiparameter photometers, Checker HC handheld colorimeters, HI931 and HI932 titrators, process controllers, reagents and calibration buffers |
Hanna product series
Portable meters include the HI98190 pH and ORP meter, the HI98192 EC, TDS and salinity meter, the HI98193 dissolved oxygen and BOD meter, the HI98199 pH, EC and DO meter and the HI9829 multiparameter water quality meter.
The HI98703 is an EPA compliant portable turbidity meter, the HI97711 a free and total chlorine photometer and the HI83414 a benchtop turbidity and chlorine meter.
Waterproof portable meters such as the HI98190 and HI98192 suit field use, with automatic temperature compensation and GLP data for audits. Turbidity measurement with the HI98703 follows EPA method 180.1, and the HI97711 photometer measures free and total chlorine for disinfection control.
Where Hanna instruments are used
Drinking water and desalination plants, wastewater treatment, environmental field surveys, aquaculture, cooling water and quality control labs.
Hanna Instruments products we list
Ordering Hanna instruments: what we need
Send the model, the parameters and ranges, the probe and cable length and any reagents or calibration solutions required.
Facts checked against Hanna Instruments' own company story and City of Woonsocket business profile, October 2026.
Browse Hanna Instruments products by category: Portable Test & Measurement.
FAQ
Questions about the Hanna HI98194 Multiparameter Waterproof Meter pH EC
Answers from our engineering team on installation, compatibility and integration.
01Which parameters does the HI98194 measure?
pH/mV, ORP, EC, TDS, resistivity, salinity, seawater sigma, dissolved oxygen, atmospheric pressure and temperature, using the HI7698194 multisensor probe.
02How deep can the probe go?
The probe is rated IP68 with a maximum depth of 20 m (66 ft), and the cable is built with a strength member rated for 68 kg intermittent use.
03How much data can it store?
Up to 45,000 complete records in up to 100 lots, with continuous or log-on-demand modes and logging intervals from 1 second to 3 hours.
04What is the difference between HI98194 and HI98195?
The HI98194 includes the galvanic dissolved oxygen sensor with three sensor inputs. The HI98195 has two inputs and no DO measurement.
05What calibration does DO need?
DO is calibrated automatically at one or two points, 0 percent and 100 percent, or at one custom point; atmospheric pressure is also calibrated at one custom point.


















Reviews