Hanna HI98193 Waterproof Portable Dissolved Oxygen and BOD Meter
Description
Dissolved oxygen readings with built-in barometer and BOD routines
The HI98193 is a waterproof portable dissolved oxygen meter for wastewater plants, aeration basins, aquaculture, rivers and process water. It reads dissolved oxygen from 0.00 to 50.00 mg/L and from 0.0 to 600.0 % saturation using the HI764073 polarographic probe, which has a protective sleeve, an internal temperature sensor and a 4 m cable in the kit.
A built-in barometer lets the meter compensate automatically for atmospheric pressure, so the operator does not need altitude charts or a separate barometer reading. Manual salinity compensation allows direct determination of dissolved oxygen in saline water. The meter also includes application software for Biochemical Oxygen Demand (BOD), Oxygen Uptake Rate (OUR) and Specific Oxygen Uptake Rate (SOUR), which suits activated-sludge process control.
Technical specifications
| Parameter | Specification |
|---|---|
| Model / order code | HI98193 |
| DO range | 0.00 to 50.00 mg/L; 0.0 to 600.0 % saturation |
| DO resolution | 0.01 mg/L; 0.1 % saturation |
| DO accuracy at 25 °C | ±1.5 % of reading ±1 digit |
| DO calibration | One or two points automatic at 100 % (8.26 mg/L) and 0 % (0 mg/L); one point manual using a user-entered mg/L or % saturation value |
| Barometric pressure | 450 to 850 mmHg, resolution 1 mmHg, accuracy ±3 mmHg within ±15 % of the calibration point |
| Temperature range | -20.0 to 120.0 °C (-4.0 to 248.0 °F); resolution 0.1 °C; accuracy ±0.2 °C excluding probe error |
| Temperature calibration | One or two points at any in-range temperature |
| Temperature compensation (DO) | Automatic, 0.0 to 50.0 °C |
| Logging | Log on demand, up to 400 samples |
| PC connection | Opto-isolated USB |
| GLP | Yes |
| Power | 4 x 1.5 V AA batteries; about 200 hours without backlight, 50 hours with backlight |
| Environment / protection | 0 to 50 °C, maximum 100 % RH, IP67 |
| Dimensions / weight | 185 x 93 x 35.2 mm / 400 g |
| Warranty (per Hanna) | 2 years |
Simple calibration and process-control functions
Hanna simplified dissolved oxygen calibration on this meter. The operator can run a one-point or two-point automatic calibration at 100 % saturation (8.26 mg/L) and at the 0 % zero-oxygen point, or enter a known value in mg/L or % saturation for a single manual point. Temperature can be calibrated at one or two points, and a user-selectable calibration time-out reminds staff when a new calibration is due. All readings are temperature compensated automatically between 0.0 and 50.0 °C.
The BOD routine supports incubation testing, while OUR and SOUR measurements help a plant assess how active the biomass in an aeration tank is. Log on demand stores up to 400 samples, Auto Hold freezes the first stable reading, and the GLP feature shows the last calibration data.
Choosing this model, and what ships in the kit
Select the HI98193 when dissolved oxygen is the primary parameter and when BOD, OUR or SOUR calculations are useful. If conductivity or pH must be recorded with the same handheld body, Hanna offers the HI98199 with interchangeable digital probes, and the HI9829 for multi-parameter field logging.
Confirm before ordering that a polarographic probe is acceptable for the application, that the 4 m cable length reaches the sampling point, and that spare PTFE membrane caps and electrolyte will be stocked. Per Hanna, the kit contains the HI764073 DO probe, two preformed PTFE membrane caps, HI7041S electrolyte solution (30 mL), HI7040 zero-oxygen solution, two 100 mL beakers, HI92000 PC software, an HI920015 micro USB cable, four AA batteries, instruction manual, quick start guide, quality certificate and an HI760193 rugged carrying case.
How the Hanna HI98193 works
The probe has a membrane that lets oxygen through to a cell. The oxygen reacts at the cell and makes a small current. The meter reads this current and turns it into a dissolved oxygen value. A temperature sensor in the probe corrects the reading for temperature. The built-in barometer corrects for air pressure, and the operator can enter the salinity for saline water.
Where the HI98193 is used
- Wastewater plants
- Aeration basins
- Aquaculture ponds and tanks
- Rivers and lakes
- Process water checks
Selection checklist for the HI98193
- Measuring range in mg/L and percent saturation
- Accuracy needed
- Probe cable length
- BOD, OUR and SOUR functions
- Logging capacity
- Battery life
- Waterproof rating
- Spare probe and membranes
Installation, commissioning and maintenance notes for the HI98193
Fit a new membrane cap and fill it with electrolyte as the manual says. Let the probe settle. Calibrate at 100 percent saturation in air and at zero oxygen. Rinse the probe after each use. Store it with the protective sleeve in place and change the batteries when the display warns.
Requesting a quotation for the Hanna HI98193
Please send the kit needed, the spare parts and the quantity. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.
HI98193 measuring range
The range is 0.00 to 50.00 mg/L and 0.0 to 600.0 percent saturation.
HI98193 accuracy
The accuracy at 25 degrees C is 1.5 percent of the reading plus or minus 1 digit.
HI98193 barometer
The barometer reads 450 to 850 mmHg with a resolution of 1 mmHg.
HI98193 temperature range
The temperature range is minus 20 to plus 120 degrees C, with a resolution of 0.1 degrees C.
HI98193 data logging
The meter logs up to 400 samples on demand and connects to a PC through an opto-isolated USB port.
HI98193 power
It runs on four AA batteries, for about 200 hours without the backlight.
HI98193 case and size
The case is rated IP67. The meter measures 185 by 93 by 35.2 mm and weighs 400 g.
Meter records for the HI98193
Record the calibration date, the membrane change and the readings taken.
Choosing the right HI98193 setup
Choose this meter for field work that needs BOD and oxygen uptake functions in the same unit.
HI98193 calibration
Calibration can be one or two points automatic, at 100 percent and 0 percent saturation, or one point manual with a value entered by the user.
HI98193 salinity compensation
Salinity is entered by hand, so the meter reads dissolved oxygen correctly in saline water.
Documents and quotation
The instruction manual is attached. For other water-quality instruments, browse Portable Test and Measurement or see the Hach HQ4200 portable meter. Submit an RFQ with the model code and quantity for availability and delivery details.
Datasheets & Documents
- Instruction Manual Hanna HI98193 Instruction Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Hanna Instruments is a manufacturer of analytical instruments for pH, ORP, conductivity, dissolved oxygen, turbidity, chlorine and titration, founded in 1978 by Oscar and Anna Nardo. Its portable meters, benchtop meters, photometers and electrodes are designed to give laboratory-style results in plant and field conditions.
Water quality instruments
Waterproof portable meters such as the HI98190, HI98192, HI98193 and HI9829 cover pH, EC, dissolved oxygen and multiparameter logging, while photometers and turbidimeters address chlorine and turbidity checks in drinking water, wastewater, boilers, cooling circuits and process lines. Features such as CAL Check validation cuvettes, GLP calibration recall and on-board data logging are described in each Hanna manual.
Sourcing through Seven Star LLC
Seven Star LLC, an independent supplier in Muscat, lists Hanna Instruments meters with their manufacturer documents so that buyers in Oman and the GCC can compare ranges, calibration standards and kit contents before requesting a quotation.
Related products
Frequently Asked Questions
0.00 to 50.00 mg/L and 0.0 to 600.0 % saturation, according to Hanna.
Yes. A built-in barometer measures 450 to 850 mmHg and compensates automatically for barometric pressure.
Yes. Manual salinity compensation is provided for direct dissolved oxygen determination in saline water.
Biochemical Oxygen Demand (BOD), Oxygen Uptake Rate (OUR) and Specific Oxygen Uptake Rate (SOUR).
The HI764073 polarographic probe with protective sleeve, temperature sensor, DIN connector and 4 m cable.

Reviews
There are no reviews yet.