Endress+Hauser PMD75-1QA7F13DCAU Deltabar Differential Pressure Transmitter 0-500 mbar

Description

Overview

The Endress+Hauser PMD75 Deltabar is a digital differential pressure transmitter built on the capacitive ceramic or metallic sensor cell platform used across the Cerabar/Deltabar S family, and this configuration, order code PMD75-1QA7F13DCAU, is factory-calibrated to a 0-500 mbar differential range. That narrow, low-end span makes the instrument especially well suited to applications where small pressure differentials carry critical process information: filter differential monitoring, low-flow orifice and venturi measurement, and closed-tank level applications where only a few millibars separate normal operation from an alarm condition.

With fast quotation turnaround and technical support, Seven Star LLC proudly supplies the PMD75 Deltabar to water treatment plants, HVAC contractors, and process industries across the Sultanate of Oman, Muscat, and the wider GCC region. Specifying the PMD75 through Seven Star LLC comes with a formal quotation, the manufacturer datasheet and technical support with selection.

Measurement Principle

The PMD75 measures differential pressure by applying the high-side and low-side process pressures across opposite faces of an internal diaphragm, which deflects in proportion to the pressure difference between the two ports. This deflection changes the capacitance of an internal measuring cell, and the transmitter’s digital electronics convert that capacitance change into a precise electrical signal representing the differential pressure, independent of absolute line pressure fluctuations.

Because the PMD75 measures the differential directly at the sensor rather than deriving it from two separate absolute measurements, it eliminates the subtraction error that would otherwise dominate a low-range 0-500 mbar reading, delivering reference accuracy of up to 0.075% of the calibrated span. This direct-measurement approach also gives the PMD75 excellent long-term stability and a fast response time, both essential when the transmitter is being used to protect equipment through filter differential alarms or to drive tight closed-loop flow control.

Engineering Design of the Endress+Hauser PMD75

The PMD75 uses a two-chamber transmitter housing, available in aluminum or stainless steel, that physically separates the terminal compartment from the electronics compartment so that field wiring can be serviced without exposure to the measuring circuitry. The process wetted parts and diaphragm seal materials are selected at the point of order to match the process medium, and the instrument supports both direct process connection and remote-seal configurations depending on the installation.

A backlit local display with a four-key operating concept allows field engineers to configure the zero and span, apply damping, and read diagnostic information without a separate handheld communicator, while the HART-based 4-20mA output integrates directly with existing control loops. This on-site configurability is a major reason plant engineers specify the Endress+Hauser PMD75 for retrofit projects where minimizing commissioning time is a priority. The PMD75 is designed to IEC 61508 and can be applied in SIL2/SIL3 safety instrumented functions, an important consideration for differential pressure loops tied to plant protection systems.

Key Features

The Endress+Hauser PMD75 combines low-range differential accuracy with rugged industrial construction. Core capabilities include:

  • Factory-calibrated 0-500 mbar differential pressure range suited to low-flow and filter monitoring duties.
  • Reference accuracy of up to 0.075% of calibrated span for stable, drift-free low-range readings.
  • Direct differential measurement that avoids the subtraction error inherent in dual absolute-pressure setups.
  • Two-chamber aluminum or stainless steel housing isolating wiring from sensitive electronics.
  • Local backlit display with four-key configuration for on-site zero, span, and damping adjustment.
  • SIL2/SIL3-capable design per IEC 61508 for use in safety instrumented systems.
  • HART-compatible 4-20mA output for seamless integration with existing DCS and PLC platforms.
  • Broad selection of wetted materials and remote-seal options to match aggressive or hygienic media.

Industrial Applications

The narrow 0-500 mbar span of this Endress+Hauser PMD75 configuration makes it a natural fit for filter differential pressure monitoring in Oman’s district cooling plants, RO desalination pretreatment trains, and HVAC air-handling systems, where clogged filters must be detected well before they compromise system performance. The same low-range sensitivity is widely used for low-flow orifice plate and venturi flow measurement in utility and process water networks across the GCC, and engineers across the region increasingly standardize on the Endress+Hauser PMD75 for these low-differential duties because of its long-term stability and minimal recalibration requirements.

With engineering support in Muscat, Seven Star LLC supplies the Deltabar PMD75 to EPC contractors and plant operators throughout the Sohar and Salalah economic zones, supporting closed-tank level measurement, blanket gas pressure monitoring, and burner management differential interlocks. Facility engineers across the region rely on Seven Star LLC for both the initial specification of the correct calibrated range and the long-term parts and calibration support that follows commissioning.

Technical Specifications

Full technical parameters for the Endress+Hauser PMD75 differential pressure transmitter, order code PMD75-1QA7F13DCAU, are summarized below to help engineers confirm the Endress+Hauser PMD75 matches their process requirements before submitting a purchase order:

Parameter Specification
Model Endress+Hauser PMD75 Deltabar
Order Code PMD75-1QA7F13DCAU
Measuring Principle Capacitive Differential Pressure
Calibrated Range 0 to 500 mbar
Accuracy Up to 0.075% of calibrated span
Output Signal 4-20mA / HART
Housing Two-chamber, aluminum or stainless steel
Safety Rating SIL2/SIL3 capable per IEC 61508
Display Local backlit display, 4-key operation

Request a Quote for Endress+Hauser PMD75-1QA7F13DCAU Deltabar Differential Pressure Transmitter 0-500 mbar

To submit a formal Request for Quote (RFQ), confirm current availability and lead time, or obtain the complete technical datasheet for the Endress+Hauser PMD75-1QA7F13DCAU Deltabar differential pressure transmitter, please contact the instrumentation division at Seven Star LLC today. Backed by manufacturer datasheet documentation, our engineers are ready to support specification, sourcing, and commissioning of your differential pressure measurement project.

Related Products

Datasheets & Documents
  • PDF Instruction Manual Endress+Hauser PMD75-1QA7F13DCAU Deltabar Differential Pressure Transmitter 0-500 mbar Manual Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Level, flow and pressure measurement account for most of the Endress+Hauser instruments engineers ask us about, and each device is defined by the order code on its nameplate. Endress+Hauser, founded in 1953 and based in Reinach, Switzerland, builds process instrumentation for liquids, gases and bulk solids.

Seven Star LLC is an independent supplier listing Endress+Hauser (E+H) flowmeters, radar and vibronic level instruments, pressure and temperature transmitters and liquid analysis equipment for plants in Oman and the GCC.

Endress+Hauser product families on this page

Level is the largest group: Micropilot free-space radar (FMR10B, FMR62 and the FMR67 for bulk solids, all 80 GHz), Levelflex guided radar (FMP50, and the FMP55 for interface measurement), the Liquiphant FTL51 vibronic point level switch and the Prosonic S FMU90 ultrasonic transmitter. Flow covers Proline Promag electromagnetic flowmeters (Promag P 300, Promag W 400) and the Prowirl F 200 vortex meter. Pressure is represented by the Cerabar PMP51B, temperature by the iTEMP TMT82 HART transmitter. For liquid analysis the listing has the Liquiline CM444 multiparameter transmitter and Memosens sensors such as the CPS11E pH electrode.

Where Endress+Hauser instruments are used

Water and wastewater plants rely on Promag W meters, radar level and Liquiline analysis. Oil and gas, chemical and power plants specify Levelflex and Micropilot on tanks and separators, Prowirl on steam and gas, and Cerabar on process lines. Food and pharmaceutical producers use hygienic versions of the same families, and cement and mining sites use the FMR67 on silos.

Ordering Endress+Hauser instruments: what we need

Send the order code and, for a replacement, the serial number from the nameplate. The extended order code is better still, because it spells out every option. Without a code we need the medium, pressure and temperature, measuring span, process connection, wetted materials, output signal or fieldbus, power supply, display and the hazardous area approval required. For flowmeters add line size and liner, for radar the tank height and nozzle size.

Frequently Asked Questions

Why choose the 0-500 mbar range for the PMD75 Deltabar?
The 0-500 mbar span gives the PMD75 fine resolution for low-differential applications such as filter monitoring and low-flow orifice measurement, where a wider-range transmitter would lack the sensitivity to detect meaningful changes.
Does the PMD75 reduce installation and commissioning downtime?
Yes. The PMD75 mounts directly to the process via standard impulse piping or a manifold, and the local display allows zero, span, and damping to be configured on-site without a separate handheld communicator, keeping commissioning fast.
What wetted materials are available for the PMD75?
The Deltabar PMD75 platform supports a range of diaphragm and wetted-part materials, including stainless steel and Hastelloy options, along with remote-seal configurations for aggressive or high-temperature media.
Can the PMD75 integrate with legacy 4-20mA control systems?
Yes. The PMD75 outputs a standard 4-20mA/HART signal, allowing it to integrate directly into existing analog loops as well as digital HART-based asset management systems without additional hardware.
Is Seven Star LLC an experienced supply partner for Endress+Hauser products?
Yes. Seven Star LLC supplies Endress+Hauser (E & H) products to customers in Oman and the GCC and can provide the manufacturer documentation and technical support on request.