- Automation & ControlView all 2,760 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Pneumatic Cylinders
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Endress+Hauser (E & H)
Endress+Hauser 5W4B Promag W 400 Electromagnetic Flowmeter
Description
Endress+Hauser 5W4B Proline Promag W 400 electromagnetic flowmeter for water and wastewater
The Endress+Hauser 5W4B is a Proline Promag W 400 electromagnetic flowmeter, described by the manufacturer as a versatile standard flowmeter for the water and wastewater industry. It measures the volume flow of conductive liquids according to Faraday’s law of magnetic induction, so the reading is practically independent of pressure, density, temperature and viscosity.
The sensor is available for nominal diameters from DN 25 to DN 3000 (1 to 120 inches), and the transmitter is housed in durable polycarbonate or aluminum. The Endress+Hauser 5W4B carries international drinking water approvals, is approved for custody transfer to MI-001 and OIML R49, offers IP68 (Type 6P) protection and provides WLAN access, an integrated web server and an integrated data logger.
Key features of the 5W4B
- Bidirectional measuring principle, virtually independent of pressure, density, temperature and viscosity
- Nominal diameter range DN 25 to 3000 (1 to 120 inches)
- Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss
- International drinking water approvals and custody transfer approval to MI-001 and OIML R49
- IP68 (Type 6P) protection, with corrosion protection to EN ISO 12944 for buried or underwater installations
- Heartbeat Technology with built-in verification and build-up detection on the 5W4B
5W4B technical specifications
| Parameter | Value |
|---|---|
| Product family | Proline Promag W 400, type 5W4B |
| Measuring principle | Electromagnetic (Faraday) |
| Nominal diameter range | DN 25 to 3000 (1 to 120 inches) |
| Flow velocity | Typically 0.01 to 10 m/s (0.03 to 33 ft/s) at specified accuracy |
| Maximum measured error, volume flow | Plus or minus 0.5 percent of reading plus or minus 1 mm/s; optionally plus or minus 0.2 percent of reading plus or minus 2 mm/s |
| Minimum conductivity | 5 microsiemens per cm for liquids in general |
| Medium temperature by liner | Hard rubber 0 to plus 80 degrees C (DN 50 to 3000); polyurethane minus 20 to plus 50 degrees C (DN 25 to 1200); PTFE minus 20 to plus 90 degrees C (DN 25 to 300) |
| Supply | DC 24 V plus or minus 25 percent; AC 24 V plus or minus 25 percent; AC 100 to 240 V minus 15 to plus 10 percent |
| Transmitter ambient temperature | Minus 40 to plus 60 degrees C |
| Transmitter protection | IP66/67, type 4X enclosure |
| Output frequency | 0 to 12,500 Hz configurable |
Values are quoted from the manufacturer Technical Information TI01046 for the 5W4B. Liner, electrode material, flange standard and communication options depend on the ordering code.
Typical applications in Oman and the GCC
In oil and gas, the 5W4B measures water flow in injection and produced water systems, firewater, cooling water and utility water, where conductive liquids are present. It is not suited to hydrocarbons with very low conductivity, which require a different principle.
Water and wastewater utilities in Oman use the device for drinking water distribution, desalination product water, irrigation and sewage lines, with custody transfer approval and drinking water approvals supporting billing and compliance. In manufacturing, it measures process water, cooling circuits and effluent, and the integrated data logger and web server simplify local checks.
Selection and compatibility notes for the 5W4B
Select the 5W4B for water and wastewater duties from small to very large pipes. The Promag W 300 offers a compact dual-compartment transmitter with up to three configurable inputs and outputs, while the Promag P 100 and H 100 serve chemical and hygienic duty. Check the conductivity of the medium, the liner temperature limits, the pressure rating of the flange and the output type before requesting a quote for the device.
Installation and commissioning of the 5W4B
Install the 5W4B sensor in a position where the pipe stays completely filled in operation, for example in a rising pipe section, and avoid mounting at the highest point of the line where air collects. Align the flange faces, use the gaskets and grounding rings or grounding connections specified for the liner, and tighten the bolts evenly and in a cross pattern. The measuring principle needs little or no straight inlet run, but the installation notes of the device should be followed for the best result. Connect the supply and signal cables through the glands supplied, keep the transmitter housing closed and sealed, and check that the potential equalisation between the medium, the pipe and the sensor is in place. On start-up of the 5W4B, enter the nominal diameter data, perform a zero-point check with a full, stationary pipe, and confirm the flow direction and the totaliser units.
Maintenance
The 5W4B has no moving parts and does not create a pressure drop, so regular maintenance is modest. Inspect the cable glands, the transmitter housing seal and the grounding connection at the intervals set by your plant routines. Where the process leaves deposits, inspect the electrode area and the liner when the line is opened. Use the built-in diagnostics and the verification functions of the device to check the sensor and the electronics without removing the meter from the line, and save the verification report for your records. Replace seals whenever the flanged joint is opened.
Related products and ordering notes
Related devices include the Promag W 300 (5W3B), the Promag P 100 (5P1B) and the Promag H 100 (5H1B). Grounding rings, remote cable sets and mounting hardware can be added to the RFQ for the 5W4B.
In short: the device is a Promag W 400 electromagnetic flowmeter for DN 25 to 3000 with drinking water approvals, custody transfer approval and IP68 sensor protection. Send an RFQ with the nominal diameter. When you prepare the enquiry, state the pipe nominal diameter, the medium and its conductivity, the process temperature and pressure, the flange standard, the supply voltage and the output you need. A complete enquiry lets us answer quickly, and it helps to say whether the meter is for custody or billing use, drinking water or a chemical duty, because that changes the liner and approval options.
Before shipment, a flowmeter should be checked for the correct nominal diameter, the right liner and electrode material, undamaged flange faces and a legible nameplate. We recommend that receiving staff compare the nameplate data with the purchase order, keep the protective covers on the flanges until installation, and store the unit in a dry place. If the application involves drinking water or custody transfer, state this in the enquiry so that the matching approvals are requested.
Documents and quotation
The official Endress+Hauser Proline Promag W 400 Technical Information (TI01046D) is attached to this page as a PDF. The front page notes corrosion protection to EN ISO 12944 for buried or underwater installation and measurement with 0 x DN inlet run, the Installation chapter starts on page 37, and the Custody transfer mode section begins on page 54. Quote the 5W4B order code from your nameplate in your request so we can check the configuration before we send a written quotation.
Other Models in the Eh Promag Range
Seven Star LLC supplies models from the Eh Promag range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser 5W4B Promag W 400 Electromagnetic Flowmeter | Electromagnetic Flowmeters | You are viewing this model |
| Endress+Hauser 5P1B Promag P 100 Process EM Flowmeter | Electromagnetic Flowmeters | View details |
Datasheets & Documents
- Datasheet Endress+Hauser Proline Promag W 400 Technical Information TI01046D (official PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser 5W4B Promag W 400 Electromagnetic
Answers from our engineering team on installation, compatibility and integration.
01What sizes are available for the 5W4B?
The datasheet lists a nominal diameter range of DN 25 to 3000 (1 to 120 inches).
02Is the 5W4B approved for custody transfer?
The datasheet lists approval for custody transfer to MI-001 and OIML R49, in addition to international drinking water approvals.
03What accuracy does the 5W4B offer?
The maximum measured error is plus or minus 0.5 percent of reading plus or minus 1 mm/s, with an optional plus or minus 0.2 percent of reading plus or minus 2 mm/s.
04What conductivity is required for the 5W4B?
Electrical conductivity of at least 5 microsiemens per cm is needed for liquids in general.
05How do I order the 5W4B?
Send an RFQ to Seven Star LLC with part number 5W4B, quantity, nominal diameter, flange standard and power supply, and we reply with availability and a quotation.


















Reviews
There are no reviews yet.