Brand: Rheonik
Rheonik RHE26 Panel and DIN Rail Mass Flow Transmitter
Description
A 0.45 kg transmitter for panels and OEM equipment
The Rheonik RHE26 is the smallest display-equipped transmitter in the range. It fits a rack, a panel cut-out or a DIN rail, weighs 0.45 kg and is aimed at general process flow, feed stock transfers and OEM applications. It handles Rheonik Coriolis sensors with mass flow, volume, density and temperature in selectable units, with positive, negative and net totalizers.
A large backlit LCD and three buttons give local configuration, and an optional lockable front cover raises the front protection to IP54.
Highlights from the datasheet
- Rack, panel or rail mounting in an IEC 61554 panel mount housing.
- Digital input configurable for zeroing, measurement hold and totalizer operation.
- Analog output configurable for mass, volume, density or temperature.
- Password-protected set-up and upload/download of configuration files, with USB for quick service.
- Built-in Assurance View diagnostics and Assurance Factor with colour-changing display.
Technical specification
| Parameter | Specification |
|---|---|
| Enclosure | IEC 61554 panel mount housing, PPE/PS-GF20; IP20, front IP54 with lockable cover |
| Ambient temperature | -20 to +60 C (-4 to +140 F) |
| Weight | 0.45 kg (1 lb) |
| Display | Backlit LCD 128 x 24, changes colour for warning or error; 3 front buttons |
| Sensor connection | Pluggable cage clamp terminal strip; cable up to 100 m (328 ft) to a remote sensor |
| Analog output | 1 x 4-20 mA, active or passive, NAMUR NE43 |
| Pulse / frequency / status | 2 configurable outputs (IEC 60946), maximum 10 kHz |
| Digital input | 1 configurable control input (IEC 60946) |
| Communications | Modbus RTU (RS485); USB to PC with RHECom |
| Power supply | 12-24 VDC +/-10%, 4 W; consumption below 5 W |
| Approvals | Code AS ATEX/IECEx or CS cCSAus for the RHE in ordinary locations; RHM sensor in all zones or divisions |
Ordering codes
Housing E1 is standard panel mount (IP20) with colour display, E2 adds a lockable cover (IP20 with IP54 front), H1 is DIN rail mount and H2 is DIN rail with lockable cover. Power is D1 (12 to 24 VDC). Software packages are SO, DO and AF only on this model, and the I/O configuration S1 gives one 4-20 mA output, two digital outputs, one input and Modbus. Hazardous-area codes are NN, AS or CS. Options are a hardware lock switch (NNH) and customized I/O presetting (NSI).
Diagnostics and software
Assurance View diagnostics monitor the meter continuously, and the Assurance Factor value can switch the display colour between white for normal operation, amber for not optimal, blue for operation at limit and red for measurement failure. Package SO covers mass flow, temperature, fixed or calculated density, standardized gas volume, batch control and password protection; DO adds measured density and Brix or Baume units; AF adds the Assurance Factor, data recording, a PID controller and partly filled pipe management. The RHECom Free software handles full set-up and data logging.
Accessories and spares
- C4 and C6 sensor cable by the metre, and pre-assembled P3 (3 m) and P0 (10 m) cables.
- Interconnection boxes IT and IM, PC cable RS, DIN rail power supply PW and Modbus-to-USB converter MO.
- Terminal adapter sets TN and TA, and the RM rack mount shade that replaces the RHE07.
How it differs from its neighbours
Compared with the RHE28, the RHE26 trades the field enclosure, the AC supply, the second analog output, HART and the analog input for a 0.45 kg panel unit that runs only on 12 to 24 VDC with one analog output and Modbus RTU. Compared with the RHE46, it keeps a colour display and keys but offers no industrial Ethernet. Choose it when the signals are simple, the supply is DC, and the display is wanted on the panel front. Read the code fields carefully because the datasheet lists only the AS and CS approval codes for this model.
Commissioning pointers
Wire the sensor cable to the pluggable terminal strip, apply power and use the three front buttons or a USB-connected PC to set units, outputs and totalizers. Configuration files can be uploaded and downloaded, so one tested setting can be cloned to several panels. Set a password before handing over, and if sealing is needed, specify the NNH hardware lock switch option when ordering.
Typical placement
Mount the RHE26 in a control room rack or an OEM machine panel in a safe area. Dust and heat in many Gulf installations favour a cabinet location, and the cable run to a remote sensor can reach 100 m.
Selection and installation notes
A mass flow transmitter must match the sensor it is connected to, so confirm the sensor model, the cable length, the supply voltage, the output types and the area classification before ordering. Keep the signal cable away from power cables, ground the shield as described in the manual, protect the housing from direct heat and water ingress and record the calibration factors and zero values at commissioning. Use the correct cable glands and seals, particularly in hazardous areas.
Information needed for a quotation
Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Related items
See flow and process measurement for related equipment. Send the sensor model and I/O needs and we will quote; confirm the full part number before ordering.
Related Rheonik products: Rheonik RHE46 Economic DIN Rail Mass Flow Transmitter, Rheonik RHE21 Ex d Field Mount Mass Flow Transmitter, Rheonik RHE42 All-Digital Field Mount Mass Flow Transmitter, Rheonik RHM06 Coriolis Mass Flow Meter Sensor 36 kg/min, Rheonik RHM20 Coriolis Mass Flow Meter Sensor 480 kg/min and Rheonik RHM160 Coriolis Mass Flow Meter Sensor 30000 kg/min.
Datasheets & Documents
- Datasheet Rheonik RHE26 panel and DIN rail transmitter datasheet (version 1.3, May 2026) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rheonik is a German manufacturer of Coriolis mass flow meters, founded in 1986 by Karl Küppers near Munich after he began developing the meter in 1984. The company moved to a larger site in Odelzhausen in 2003. GE acquired the Rheonik Coriolis line in 2008, and in 2015 a management buyout formed Rheonik Messtechnik GmbH, which took the business back out of GE.
Seven Star LLC is an independent supplier in Muscat. We list Rheonik sensors and transmitters with their official datasheets for oil and gas, petrochemical, chemical and filling applications in Oman and the GCC.
Rheonik company profile
| Founded | 1986, near Munich, Germany, by Karl Küppers |
|---|---|
| Headquarters | Odelzhausen, Bavaria, since 2003 |
| Technology | Coriolis mass flow, with density and temperature |
| Corporate history | GE Sensing (2008), management buyout as Rheonik Messtechnik GmbH (2015) |
| Product families | RHM series Coriolis sensors (including RHM06, RHM40, RHM100 and RHM160), high-pressure and high-temperature sensor versions, RHE21 Ex d, RHE42 field mount and RHE46 DIN rail transmitters |
Milestones
- 1984: Karl Küppers begins developing the Rheonik meter.
- 1986: Rheonik is founded.
- 2003: The company moves to Odelzhausen.
- 2008: GE acquires the Rheonik Coriolis line.
- 2015: A management buyout forms Rheonik Messtechnik GmbH.
Rheonik product series
RHM sensors on this site cover a wide range of sizes: the RHM06 for about 36 kg/min, the RHM20 for 480 kg/min, the RHM40 for 1500 kg/min, the RHM100 for 12,000 kg/min and the RHM160 for 30,000 kg/min. Tube materials, pressure ratings and process connections are chosen through the order code.
RHE transmitters include the RHE21 Ex d field mount transmitter, the RHE42 all-digital field transmitter, the RHE28 universal mount transmitter and the compact RHE26 and RHE46 units for panel or DIN rail mounting.
Where Rheonik meters are used
Custody transfer and loading of hydrocarbons, chemical injection and dosing, high-pressure gas and hydrogen measurement, batching and filling, and measurement of viscous or hot fluids.
Rheonik products we list
Ordering Rheonik meters: what we need
Give the fluid, flow range, line pressure and temperature, process connection and hazardous area class. Sensor and transmitter approvals must match, so we confirm the full order code for both before ordering.
Facts checked against Flow Control and Processing coverage of the 2015 buyout and GE Rheonik specification sheets, October 2026.
Browse Rheonik products by category: Flowmeters.
FAQ
Questions about the Rheonik RHE26 Panel and DIN Rail Mass Flow
Answers from our engineering team on installation, compatibility and integration.
01How can the RHE26 be mounted?
As a rack, panel or DIN rail unit: housing codes E1 and E2 are panel mount, H1 and H2 are DIN rail, with lockable cover options.
02What outputs are available?
One 4-20 mA output, active or passive, two pulse/frequency/status outputs to 10 kHz, one control input and Modbus RTU over RS485.
03Does it have a display?
Yes. A backlit colour LCD of 128 x 24 pixels that changes colour on warning or error, and three front buttons.
04What power does it need?
12-24 VDC +/-10%, 4 W; power consumption is below 5 W.
05Can it work with a sensor in a hazardous area?
It operates Rheonik RHM sensors in hazardous areas; the transmitter itself is for ordinary locations with associated-equipment codes AS (ATEX/IECEx) or CS (cCSAus).