Brand: ABB
ABB AF26-30-00-14 3-Pole Contactor 11 kW, 250-500 V Coil
Description
ABB AF26-30-00-14 11 kW contactor with a 250 to 500 V coil
The ABB AF26-30-00-14 is the 250 to 500 V coil version of the standard AF26 contactor. It has three N.O. main poles for 26 A AC-3 (11 kW at 400 V) and no built-in auxiliary contact. The order code is 1SBL237001R1400, the EAN is 3471523110946 and the net weight is 0.350 kg.
The high coil range is the distinguishing feature. Most contactors in a panel run from 24 V DC or 230 V AC control, but some older installations and certain motor control centres switch coils directly at 400 V or 415 V. The AF26-30-00-14 is made for those, and it can also be used on DC control supplies within 250 to 500 V.
AF26-30-00-14 part number structure
| Group | Meaning in AF26-30-00-14 |
|---|---|
| AF26 | 26 A AC-3, 11 kW at 400 V |
| 30 | Three N.O. main poles |
| 00 | No built-in auxiliary contact |
| 14 | Coil code for 250 to 500 V 50/60 Hz and 250 to 500 V DC |
Standard AF coil codes 11 to 14 cover 24 to 60 V, 48 to 130 V, 100 to 250 V and 250 to 500 V in turn. The 14 coil is also the only one of the four that weighs 0.350 kg on this body, as the others are 0.310 kg.
Technical specifications of the AF26-30-00-14
| Parameter | Specification |
|---|---|
| Manufacturer / part number | ABB / AF26-30-00-14 |
| Order code / EAN | 1SBL237001R1400 / 3471523110946 |
| Poles and built-in contacts | 3 N.O. main poles; no built-in auxiliary contact |
| Coil voltage Uc | 250 to 500 V 50/60 Hz and 250 to 500 V DC |
| Coil consumption (AF) | Pull-in average 50 VA (AC) or 50 W (DC); holding 2.2 VA / 2 W (AC) or 2 W (DC) |
| Coil operating limits | 0.85 x Uc min to 1.1 x Uc max at 60 °C; 0.85 x Uc min to Uc max at 70 °C |
| Operating time | N.O. closing 40 to 95 ms; N.O. opening 11 to 95 ms |
| Rated operational voltage Ue (IEC) | 690 V max. |
| Rated frequency limits | 25 … 400 Hz |
| Conventional free-air thermal current Ith (40 °C, 10 mm²) | 50 A |
| AC-1 rated operational current | 45 A at 40 °C; 40 A at 60 °C; 32 A at 70 °C |
| AC-3 rated operational current | 26 A at 220 to 440 V; 23 A at 500 V; 17 A at 690 V |
| AC-3 rated power | 6.5 kW at 230 V; 11 kW at 400/415 V; 15 kW at 440, 500 and 690 V |
| AC-8a (no overload relay, 400 V, 40 °C) | 30 A / 15 kW |
| Making / breaking capacity AC-3 | 10 x Ie / 8 x Ie |
| Short-circuit protection (no overload relay) | gG fuse 50 A up to 500 V AC |
| Short-time withstand current Icw | 700 A for 1 s; 350 A for 10 s; 225 A for 30 s; 150 A for 1 min; 50 A for 15 min |
| Maximum breaking capacity (cos phi 0.45) | 500 A at 440 V; 200 A at 690 V |
| Heat dissipation per pole | 1.8 W (AC-1); 0.6 W (AC-3) |
| Switching frequency | 600 cycles/h AC-1; 1200 cycles/h AC-3; 150 cycles/h AC-2/AC-4 |
| Mechanical durability | 10 million operating cycles |
| UL/CSA (UL 508) | NEMA size 1; general use 45 A at 600 V AC; 3-phase 7.5 hp at 200-240 V, 15 hp at 440-480 V, 20 hp at 550-600 V |
| Net weight | 0.350 kg |
These are the values published in the ABB technical datasheet for the AF26-30-00 range.
Using a 250 to 500 V coil on the AF26-30-00-14
Driving a coil directly from a 400 V line-to-line supply removes the control transformer from a simple motor starter, but it puts line voltage on the start/stop circuit, so wiring, insulation and enclosure labelling must be designed for it. The coil operating band is 0.85 times 250 V (212.5 V) to 1.1 times 500 V (550 V) at up to 60 °C, which tolerates ordinary voltage swings on a 400 V network.
The built-in electronic interface provides the high pull-in and low holding current, together with surge protection, so no external suppressor is required. Because this is the standard (non-Z) coil, it takes about 50 VA at pull-in and should not be driven directly from a 24 V DC PLC output.
Matching parts for the AF26-30-00-14
The TF42 thermal overload relay mounts directly under the AF26-30-00-14. For motors around 11 kW, a range such as TF42-24 (20 to 24 A) is typical; lower-rated motors use TF42-20, TF42-16 or lower. Side and front auxiliary blocks (CAL4-11, CA4-10, CA4-01) supply the feedback contacts that this contactor lacks, and VEM4 provides a mechanical and electrical interlock for reversing. A BEA26-4 link block connects the contactor to a manual motor starter.
Related contactor types are the AF26-30-00-13 with the 100 to 250 V coil, the AF26Z-30-00-23 low-consumption version and the AF09-30-01-13 for 4 kW.
Selection checklist for the AF26-30-00-14
- Control voltage must be 250 to 500 V AC or DC; choose another coil code for lower voltages.
- Motor: 26 A AC-3 at 400 V (11 kW); 23 A at 500 V and 17 A at 690 V.
- No auxiliary contact is built in; add blocks as needed.
- Overload protection: TF42 range selected from the motor nameplate.
- Consider the heat in the enclosure: 1.8 W per pole at AC-1 rating and 0.6 W per pole in AC-3.
- Standard: UL/CSA rating is NEMA size 1, general use 45 A at 600 V AC.
Installation and maintenance of the AF26-30-00-14
Mount on a 35 mm DIN rail or with two M4 screws. Main terminals accept 2.5 to 10 mm² solid or stranded (one or two conductors) and 1.5 to 10 mm² flexible with a ferrule; the stripping length is 14 mm and the screws are M4, tightened to 2.5 Nm. Coil and auxiliary terminals are M3.5 and take 0.75 to 2.5 mm² at 1.2 Nm.
Since the coil may be connected to line voltage, isolate the control circuit completely before working on it and label the enclosure accordingly. In service, check the coil voltage, the contact surfaces and the terminal torque at scheduled shutdowns. The datasheet gives ambient limits of -25 to +60 °C with an overload relay and -40 to +70 °C without.
AF26-30-00-14 in Gulf industrial panels
The AF26-30-00-14 appears in existing 400 V control schemes for pump houses, ventilation fans, compressors and conveyor starters, particularly where spare coils or replacement contactors are needed for older installations in Oman and the GCC. It also suits new direct-on-line starters designed with line-voltage control. For sites with hot enclosures, check the thermal derating: AC-1 current falls from 45 A at 40 °C to 32 A at 70 °C.
When replacing a contactor, compare the coil code, the pole arrangement and any auxiliary blocks fitted on the old unit, since these determine whether the replacement is a direct fit.
AF26 standard coil family around the AF26-30-00-14
| Type | Coil range | Order code |
|---|---|---|
| AF26-30-00-11 | 24 to 60 V AC, 20 to 60 V DC | 1SBL237001R1100 |
| AF26-30-00-12 | 48 to 130 V AC and DC | 1SBL237001R1200 |
| AF26-30-00-13 | 100 to 250 V AC and DC | 1SBL237001R1300 |
| AF26-30-00-14 | 250 to 500 V AC and DC | 1SBL237001R1400 |
RFQ information for the AF26-30-00-14
- Exact type AF26-30-00-14 (1SBL237001R1400) and quantity.
- Control supply voltage, phase arrangement and frequency.
- Motor power and nameplate current.
- Overload relay and contact blocks needed.
- Delivery requirement.
Documents and quotation
A technical datasheet for the AF26-30-00-14 is attached on this page with the ordering table, ratings and accessory details.
Seven Star LLC supplies ABB low-voltage control gear in Oman and the GCC. Send us the part number AF26-30-00-14 and your quantity, and we will confirm availability and a quotation.
Other Models in the Abb Af26 3pole Contactor Range
Seven Star LLC supplies models from the Abb Af26 3pole Contactor range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ABB AF26Z-30-00-23 3-Pole Contactor 11 kW, Low-Consumption | Contactors & Overload Relays | View details |
| ABB AF26-30-00-14 3-Pole Contactor 11 kW, 250-500 V Coil | Contactors & Overload Relays | You are viewing this model |
Datasheets & Documents
- Datasheet ABB AF26-30-00-14 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB AF26-30-00-14 3-Pole Contactor 11 kW, 250-500 V
Answers from our engineering team on installation, compatibility and integration.
01What control voltage does the AF26-30-00-14 need?
The coil is rated 250 to 500 V at 50/60 Hz AC and 250 to 500 V DC. It operates from 0.85 times the minimum to 1.1 times the maximum voltage at ambient temperatures up to 60 degrees C.
02What power can the AF26-30-00-14 switch?
In AC-3 it is rated 26 A at 400 V, equal to 11 kW. At 440 V and above the rated power is 15 kW, and the current is 23 A at 500 V and 17 A at 690 V.
03Can the AF26-30-00-14 be driven from a PLC output?
Not directly. Only the AF..Z contactors with the 24 to 60 V coil are intended for direct control by a 24 V DC PLC output. This standard 250 to 500 V coil needs an interposing relay.
04Does the AF26-30-00-14 have built-in auxiliary contacts?
No. The 00 in the type code means none are fitted. Front or side auxiliary blocks such as CA4-10, CA4-01 or CAL4-11 can be added.
05What is the weight and order code of the AF26-30-00-14?
The ABB order code is 1SBL237001R1400, the EAN is 3471523110946 and the net weight is 0.350 kg, slightly more than the lower-voltage coils, which weigh 0.310 kg.


















Reviews