- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Automation Accessories
- Vibration Monitoring
- Controllers & Data Acquisition
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Industrial Computers
- Servo Drives
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Isolator & Barrier
- Automation Software
- Machine Vision
- Robotics
Brand: Xtralis
VESDA Detector VLC505
Description
The VESDA Detector VLC505 is a state-of-the-art air sampling smoke detection device designed to deliver early warning fire detection in environments where rapid response is critical. Featuring advanced laser-based detection technology, this compact yet powerful detector continuously monitors air samples drawn through a network of sampling pipes to identify the presence of smoke at the earliest possible stage.
Ideal for applications such as data centers, server rooms, telecommunications hubs, cleanrooms, and high-value storage areas, the VESDA Detector VLC505 ensures maximum protection with minimal disruption. Its detection sensitivity can be adjusted to meet the exact needs of the environment, from ultra-sensitive detection in clean environments to robust monitoring in industrial settings.
One of the key advantages of the VESDA Detector VLC505 is its reliability. With active air sampling, the detector can detect smoke before it becomes visible to the human eye or activates traditional spot-type detectors. This enables earlier interventions and reduces the risk of fire-related damages or downtime. Its built-in event log, auto-learn function, and alarm threshold configuration contribute to intelligent, adaptable protection.
Installation and maintenance of the VLC505 are straightforward, making it suitable for both new construction and retrofit projects. It supports a wide range of configurations, including stand-alone or integrated systems via VESDAnet. With LED indicators and optional remote displays, users can monitor detector status and receive real-time alerts when smoke thresholds are crossed.
The VESDA Detector VLC505 is compliant with major international fire detection standards, ensuring peace of mind for safety managers and facility operators. It’s equipped with fault diagnostics and remote testing capabilities, allowing users to perform routine checks without interrupting operations.
In conclusion, the VESDA Detector VLC505 offers unmatched performance in early smoke detection, making it a preferred choice for sensitive and mission-critical applications. Its intelligent design, adaptability, and proven reliability make it an essential component of any advanced fire protection strategy, and a natural fit for Oman’s data center, telecommunications, and industrial control facilities where early warning fire detection is a regulatory and operational priority.
Technical Specifications
Per Xtralis (now part of Honeywell) official product documentation, the VLC-505 is the VesdaNet-compatible model in the VESDA LaserCOMPACT (VLC) range, distinct from the non-networkable VLC-500:
| Detection technology | Laser light-scatter smoke detection, active air sampling |
| Sensitivity range | 0.0015% to 6.25% obs/ft (0.005% to 20% obs/m) |
| Alarm thresholds | 3 programmable levels: Alert, Pre-Alarm, Fire |
| Pipe network coverage | Up to 8,000 sq ft (800 sq m); pipe configurations e.g. 1x80m or 2x50m |
| Pipe diameter | Internal diameter approx. 9/16″ to 7/8″ |
| Communication | Relays plus VESDAnet (VLC-505 networkable model) |
| Dimensions | 225 x 225 x 85 mm |
| Certifications | UL, ULC, FM, LPCB, VdS, CFE, plus additional regional listings |
| Ideal use case | Single environment, space-constrained areas |
VLC-505 vs VLC-500
The VLC-505 adds VESDAnet networking capability to the base LaserCOMPACT platform, letting multiple detectors share a common network for centralized monitoring, cross-referencing between detectors, and connection of optional remote display or annunciator modules — a capability the simpler VLC-500 (relay-only) model does not provide. This makes the VLC-505 the appropriate choice wherever a facility needs several detectors reporting to a common fire panel or building management system rather than operating as isolated stand-alone units.
Industrial and Critical-Facility Applications
The VLC-505 is specified for spaces where a spot-type smoke detector would respond too late or is impractical to install directly — server rooms and data halls, telecommunications equipment rooms, control rooms, electrical switchgear rooms, and cleanroom or high-value storage areas common to industrial and commercial facilities across Oman. Because it draws air continuously through a sampling pipe network rather than waiting for smoke to reach a ceiling-mounted spot detector, it can detect an incipient fire condition — such as early overheating in an electrical cabinet or IT equipment — well before visible smoke or open flame develops, giving facility operators time to intervene before an automatic suppression system or evacuation is triggered.
Seven Star LLC supports data centers, telecom operators, and industrial control rooms across Muscat, Sohar, and the wider GCC with genuine VESDA aspirating detection hardware, from initial pipe network design through detector commissioning and VESDAnet integration with existing fire alarm control panels.
Design and Commissioning Notes
Pipe network design for the VLC-505 must respect the manufacturer’s maximum coverage area and hole-spacing rules to guarantee the specified transport time and sensitivity at the far end of each sampling pipe run, so a facility’s ceiling height, HVAC air-change rate, and the value of the protected contents should all factor into how conservatively the alarm thresholds are set. Because the unit supports three independently programmable alarm levels, a common configuration uses the Alert level for early staff notification, Pre-Alarm to trigger a more urgent response, and Fire to initiate the facility’s automatic suppression or shutdown sequence, spacing the response steps so operators have time to investigate before the most disruptive action is taken.
Ordering Information
Seven Star LLC can also supply the complementary pipe network components, sampling points, and the optional remote LED display module used alongside the VLC-505 in a complete VESDAnet installation.
Confirm whether your project specifies the networked VLC-505 or the simpler relay-only VLC-500, since the two share a common housing but differ in networking capability, and provide protected floor area, ceiling height, and any regional fire code requirements so the correct pipe network and detector quantity can be specified before ordering.
Why Seven Star LLC
Seven Star LLC supplies genuine VESDA VLC-505 aspirating smoke detectors and related pipe network accessories to facilities across Oman and the GCC, and can advise on pipe network design, sensitivity threshold configuration, and VESDAnet integration for your specific protected space.
Related Products
Datasheets & Documents
- Datasheet Xtralis VESDA Detector VLC505 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Xtralis is the maker of VESDA aspirating smoke detectors, now part of Honeywell. The company was founded in Australia in 1982 and incorporated in 1983 as Vision Fire & Security Pty Ltd. It later added video and perimeter security through acquisitions, and Honeywell agreed to buy Xtralis in February 2016.
Seven Star LLC supplies Xtralis VESDA detectors and spare parts to facility and fire system teams in Oman, including filter cartridges, detection chambers, power supplies and remote displays.
Xtralis company profile
| Founded | 1982, Australia, as Vision Fire & Security |
|---|---|
| Best-known product | VESDA (Very Early Smoke Detection Apparatus) aspirating smoke detection |
| Ownership | Honeywell, after an agreement announced on 4 February 2016 |
| Acquisitions | ASIM Technologies and VSK Group in 2007, HeiTel Digital Video in 2011 |
| Product families | VESDA-E VEP, VEU and VES aspirating detectors, VESDA VLF, ICAM, OSID open-area beam detection, ADPRO perimeter and video security |
Milestones
- 1982: Vision Fire & Security is founded in Australia.
- 2007: Xtralis acquires ASIM Technologies and VSK Group.
- 2016: Honeywell agrees to acquire Xtralis.
Xtralis VESDA detectors and spares listed here
Two generations appear in the listing. From the earlier VESDA range come the VLC-505, a compact detector for single areas with VESDAnet communication, and the VESDA VLI, built for dusty industrial environments. The current generation is VESDA-E, represented by the VEP detector.
Spare parts follow VSP numbers:
- VSP-962 filter cartridge for VESDA-E detectors
- VSP-972 filter cartridge for the VESDA-E VEA
- VSP-964-03 smoke detection chamber (MK3) for VESDA-E
System accessories listed include the VPS-215-E power supply and the VRT-J00 remote display and relay unit.
Where VESDA aspirating detection is used
Aspirating detection is chosen where point detectors respond too late or cannot be reached for testing: data halls and telecom rooms, switchgear and control rooms, clean rooms, cold stores, warehouses with high racking, cable tunnels and heritage buildings. The VLI extends this to dirty areas such as conveyors and process buildings. Such sites are common in the GCC, where data centers and utility substations are expanding.
Xtralis products we list
Ordering VESDA parts: what we need
Send the detector model and part number from the detector label, for example VLC-505 or the VEP variant code, with the serial number. VESDA-E detectors are made in several variants by pipe count and display type, so the complete code is needed. For filters and chambers, give the VSP number and the detector it serves. For a new detector, the pipe network design has to exist first: tell us the model selected by your designer and the fire panel interface required. We check each number against Xtralis documentation.
Facts checked against published Xtralis company histories and trade press, October 2026.
Browse Xtralis products by category: Fire & Gas Detector.
Related products
Frequently Asked Questions
It uses a laser-based aspirating smoke detection principle: air is continuously drawn through a sampling pipe network into the unit's laser chamber, where light scatter from smoke particles is measured before particles become visible to the naked eye.
The VLC-505 detects smoke obscuration from 0.5% to 15% obs/m, covering everything from very early pre-alarm warning to conventional fire-alarm-level sensitivity in one unit.
It provides three independently configurable alarm levels - Alert, Pre-Alarm, and Fire - each adjustable within its own obscuration range, allowing the response strategy to be tuned to the protected space.
The VLC-505 is a single-pipe-inlet aspirating detector, designed for compact single-room or small-area protection rather than the multi-pipe branched networks used by larger VESDA models.
It uses a dual-stage dust filter - a first stage that removes coarse dust and dirt from the sampled air and a second ultra-fine stage that protects the laser detection chamber - which helps maintain long-term measurement stability in dusty industrial environments.

Reviews
There are no reviews yet.