The MEDC SM87LED Ex LED beacon range is a high-intensity explosion-proof LED beacon family from the Crouse-Hinds series, certified Ex d IIC T6 Gb for use in Zone 1 and Zone 2 hazardous areas, with weatherproof IP66 and IP67 protection.

Combining long-life LED technology with certified flameproof construction, the SM87LED provides reliable visual alarm signalling in the most demanding offshore, marine, and industrial installations.

Engineering & Design

The beacon is built in either 316L stainless steel or LM25 marine-grade aluminium alloy, both corrosion resistant and lightweight for harsh environments. The glass lens is available in multiple colours with optional lens guards for additional mechanical protection.

Certified to ATEX (Baseefa 03ATEX0222), IECEx, UL, TR CU, INMETRO, and CQST schemes, the SM87LED can be initiated by telephone ringing tone or low-voltage control signals, and SIL 2 certification to IEC 61508 is available on selected versions.

Key Features

  • High-intensity LED light source with extended lifetime
  • Ex d IIC T6 Gb and Ex tb IIIC T55°C/T70°C Db certification
  • ATEX, IECEx, UL/CSA, TR CU, INMETRO, and CQST approvals
  • SIL 2 certified versions to IEC 61508
  • IP66 and IP67 weatherproof protection
  • 316L stainless steel or LM25 marine grade alloy construction
  • Glass lens in various colours with optional lens guard
  • Telephone ring tone or low voltage control initiation
  • Up to 4 cable entries M20/M25 ISO or 1/2″ and 3/4″ NPT
  • Certified operating temperature -20°C to +55°C

Applications

  • Offshore platforms and marine vessels
  • Oil and gas processing plants
  • Hazardous area alarm signalling
  • Fire and gas alarm visual indication

Specifications

Model SM87LED high intensity LED beacon
Certification Ex II 2GD, Ex d IIC T6 Gb, Ex tb IIIC T55°C/T70°C Db
Approvals ATEX Baseefa 03ATEX0222, IECEx BAS 09.0059, UL/CSA, TR CU, INMETRO, CQST
Functional Safety SIL 2 rated versions to IEC 61508
Protection IP66 and IP67
Housing 316L stainless steel (S) or LM25 marine grade alloy (A)
Lens Glass, various colours, optional guard
Initiation Telephone ringing tone or low voltage control signals
Cable Entries Up to 4× M20/M25 ISO or 1/2″ / 3/4″ NPT
Temperature -20°C to +55°C operating, certified to +70°C
Weight Approx 3.8kg (stainless), 2.0kg (alloy)

Compatibility & Integration

The SM87LED connects to alarm and fire and gas systems via telephone or low-voltage control signalling, with flameproof cable entries compatible with standard hazardous area glands and junction boxes.

Hazardous Area Support

Seven Star LLC supports complete signalling solutions for classified areas, including beacon selection, cable gland specification, and integration with fire and gas alarm systems for offshore and onshore projects.

Our specialists provide documentation packs and technical advice for Zone 1 and Zone 2 installations across the GCC.

Operational Benefits

Long-life LED technology in the SM87LED reduces lamp replacement frequency in hard-to-reach hazardous area locations, cutting maintenance effort and exposure.

Low power consumption eases load on alarm and fire and gas systems, while the stainless steel option ensures durability in corrosive offshore atmospheres.

Telephone initiation compatibility supports simple integration into legacy tone-based alarm circuits.

For hazardous areas where the MEDC SM87LED must operate safely, Seven Star LLC supplies the MEDC SM87LED with full certificate packs, and our specialists help integrate every MEDC SM87LED into your alarm system.

The SM87LED range covers the LED beacon variants with the different voltage and the mounting options for the hazardous area signalling.

The MEDC SM87LED Ex LED beacon range covers the low power LED signal lamps of the hazardous area, and the MEDC SM87LED Ex LED beacon range is used for the visual alarm in the process plants and the offshore platforms.

The MEDC SM87LED Ex LED beacon range covers the 24 VDC and the other voltage variants, and the SM87LED range is supplied for the zone 1 installation.

Why Seven Star LLC

Seven Star LLC supplies genuine MEDC and Crouse-Hinds series signalling products from our Muscat, Oman facility, serving offshore and onshore projects across the GCC with full certification documentation.

Our specialists support hazardous area product selection, cable entry planning, and compliance documentation for your installation.

Selecting the Right SM87LED Variant

Each beacon in the range is defined by its supply voltage, housing material, lens colour, cable entry type and certification. Before ordering from the MEDC SM87LED Ex LED beacon range, confirm the gas group and temperature class required for the installation zone, the supply voltage available from the alarm system, the lens colour defined in the plant alarm philosophy, and the cable gland size. For replacements, read the full part number and certification label on the installed beacon.

  • Hazardous area classification of the mounting location
  • Supply voltage and initiation method
  • Lens colour and whether a lens guard is required
  • Number, size and thread type of cable entries

Installation and Commissioning

Installation in a hazardous area must be carried out by competent personnel in line with IEC 60079-14 and the manufacturer instructions. Use certified flameproof cable glands or stopping plugs suitable for the enclosure, close unused entries with certified blanking elements, and keep the flameproof joints clean and undamaged. Mount the beacon where it is clearly visible from the areas it serves. After installation, test the beacon from the alarm system and record the test.

Inspection and Maintenance

Include beacons in periodic Ex inspections. Check the enclosure for corrosion and damage, the lens for cracks or dirt, the gland condition and the cover tightness. Never open the enclosure while energized in a hazardous area unless the site permit allows it. LED beacons need no lamp changes, but a regular functional test confirms the complete alarm circuit.

Use in Oman and the GCC

These beacons are used on oil and gas facilities, offshore installations, tank farms and chemical plants, where high temperatures, sun and salt air demand durable, certified signalling equipment.

Request a Quote for MEDC SM87LED Ex LED Beacon Range

For the MEDC SM87LED, Ex d LED beacon or any related control and instrumentation requirement, contact the Seven Star LLC team. Submit a formal inquiry through our RFQ page with your required quantity and specification, and our specialists will respond with a detailed commercial proposal and the official MEDC documentation.

Other Models in the MEDC SM87 Hazardous Area Beacons Range

Seven Star LLC supplies models from the MEDC SM87 Hazardous Area Beacons range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
MEDC SM87 Hazardous Area Beacon, ATEX Zone 1 & 2 Ex dFire & Gas SystemsView details
MEDC SM87LED Ex LED Beacon RangeFire & Gas SystemsYou are viewing this model
MEDC (Eaton) SM87BGLAD1T1B1NNRAS Explosion-Proof Beacon 24VDCFire & Gas SystemsView details
MEDC SM87JB Ex Junction BoxAutomation AccessoriesView details

Related Products

Datasheets & Documents
  • PDF Datasheet MEDC SM87LED Ex LED Beacon Range Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand
Beacons, sounders and manual call points for hazardous areas are what MEDC is known for on offshore platforms, in refineries and in tank farms. Units in service may be labeled MEDC, Cooper MEDC or Eaton MEDC, and in each case the model code on the label identifies the product. Seven Star LLC is an independent supplier listing MEDC explosion-protected beacons, alarm sounders, call points and junction boxes for fire and gas systems in Oman and the GCC.

MEDC product families on this page

Visual signals include the XB15 xenon beacon, the LD15 LED beacon and the SM87 beacon family with its SM87LED version, for Zone 1 and Zone 2 areas. The DB3 is the alarm sounder. Manual alarm devices are the BG manual call point and a manual release unit from the BG2 call point series, listed as BG2E. The SM87JB junction box completes the field wiring. These devices are ordered with long codes such as SM87BGLAD1T1B1NNRAS or BGEB4B6B1DDCF7R, in which each block of characters selects an option.

Where MEDC signaling equipment is used

MEDC beacons and sounders announce fire, gas and process alarms on production platforms, in gas plants, refineries, chemical plants, loading terminals and marine vessels. Call points give personnel a way to raise the alarm by hand, and the same devices are wired into fire and gas panels from many system builders.

Ordering MEDC beacons and call points: what we need

The complete order code from the label or the project datasheet is the best starting point. If you are selecting from scratch, send the supply voltage, lens color for beacons, tone and sound level for sounders, enclosure material and finish color, cable entry size and number, the certification required and the ambient temperature. For call points add the switch arrangement, any series or end-of-line resistor values, and label or duty plate text.

Frequently Asked Questions

Which certifications does the SM87LED carry?
It is certified Ex d IIC T6 Gb and Ex tb IIIC Db under ATEX (Baseefa 03ATEX0222), IECEx, UL, TR CU, INMETRO, and CQST schemes.
Is the beacon available in stainless steel?
Yes, the SM87LEDS version uses 316L stainless steel and the SM87LEDA version uses LM25 marine grade alloy, both corrosion resistant.
What is the ingress protection rating?
The beacon is rated IP66 and IP67 for weatherproof operation in exposed offshore and industrial locations.
How is the beacon initiated?
It can be initiated by telephone ringing tone or low voltage control signals, making it flexible for fire and gas alarm systems.
What is the certified temperature range?
The SM87LED operates from -20°C to +55°C, with certified temperature class T6 up to +70°C ambient.