SICK AFM60A-S4IB018x12 Multi-Turn Absolute Encoder, EtherNet/IP
Description
Overview
The SICK AFM60A-S4IB018x12 is a multi-turn absolute encoder with an EtherNet/IP interface. It combines an 18-bit single-turn resolution of 262,144 steps with 4,096 revolutions of 12-bit multi-turn range, so the shaft position is reported unambiguously over 4,096 turns even after a power loss. The code belongs to the AFS/AFM60 family; in that naming, AFM is the multi-turn type and the Ethernet variant talks directly to Rockwell-style controllers and any EtherNet/IP scanner without a separate gateway.
The housing is the familiar 60 mm class with a 10 mm solid shaft carrying a flat, a face mount flange and three axial M12 connectors: one A-coded male for power and two D-coded females for the network, which allows daisy-chain and ring topologies. It is a good fit for axes where position must survive restarts, such as valves, gates, cranes and long travel carriages.
Seven Star LLC is an independent supplier serving Oman and the GCC. This page uses the manufacturer data sheet of part number 1055334.
Network functions of the AFM60A-S4IB018x12
The encoder implements encoder profile V4.1 class 3 and works at 10 Mbit/s or 100 Mbit/s over CAT-5e cable. The requested packet interval ranges from 5 ms to 750 ms, and the initialization time after power-on is approximately 10 seconds, which a start-up sequence should allow for. Device Level Ring is supported, so a ring of encoders and drives can heal itself after a cable break.
The parameter set includes the number of steps per revolution, the number of revolutions, PRESET, the counting direction and the sampling rate for speed calculation. Beyond position, the unit can output speed, acceleration and temperature, scalable limit values for position ranges, speed and acceleration, round axis functionality and a heartbeat. Diagnostics record minimum and maximum temperature, maximum speed, power-on counter, operating hours and motion hours, direction-change counters, minimum and maximum operating voltage and signal monitoring for singleturn and multiturn.
Technical specifications of the SICK AFM60A-S4IB018x12
| Parameter | Value |
|---|---|
| Type / part number | AFM60A-S4IB018x12 / 1055334 |
| Interface | EtherNet/IP, encoder profile V4.1 class 3 |
| Steps per revolution | 262,144 (18 bit) |
| Number of revolutions | 4,096 (12 bit) |
| Error limits | 0.03 degrees |
| Repeatability | 0.002 degrees |
| Data rate | 10 Mbit/s, 100 Mbit/s |
| Requested packet interval | 5 ms to 750 ms |
| Initialization time | approximately 10 s |
| Supply voltage | 10 V to 30 V |
| Power consumption | 3 W or less without load |
| Connections | 1 x M12 male 4-pin A-coded, 2 x M12 female 4-pin D-coded, axial |
| Mechanical design | Solid shaft, face mount flange |
| Shaft diameter / length | 10 mm with flat / 19 mm |
| Weight | 0.2 kg |
| Shaft / flange / housing material | Stainless steel / aluminum / aluminum |
| Start-up torque | 0.5 Ncm at 20 degrees Celsius |
| Operating torque | 0.3 Ncm at 20 degrees Celsius |
| Permissible shaft load | 80 N radial, 40 N axial |
| Operating speed | up to 9,000 per minute |
| Moment of inertia | 6.2 gcm2 |
| Bearing lifetime | 3 x 10 to the 9th revolutions |
| Enclosure rating | IP65 shaft side, IP67 housing side with mating connector |
| Operating temperature | minus 40 to plus 85 degrees Celsius |
| Shock / vibration | 100 g, 6 ms / 30 g, 10 Hz to 2,000 Hz |
| MTTFD | 80 years |
How AFM60A-S4IB018x12 differs from other AFM60 and AFS60 variants
Within the family, the interface and turn range are fixed by the code. The AFS60A-S4PA262144 is a single-turn SSI device with 18 bit and a 12-pin M23 connector, and it needs a clock line from the controller. The SICK AFM60A-S4IB018x12 is multi-turn, adds 12 bit of revolutions and replaces the SSI clocking with an Ethernet network connection, so cabling, power range and diagnostics differ entirely.
An AFM60 for PROFINET or another fieldbus shares the housing but speaks a different protocol; confirm EtherNet/IP and the part number 1055334 against the controller documentation, in particular the EDS file and the profile class.
Typical applications in Oman and the GCC
Multi-turn absolute feedback is valuable on large gate and valve operators, on travelling cranes and hoists, on long linear axes driven by rack and pinion, and on winches where the position must remain known after a power failure. The Ethernet connection also makes diagnostics available to maintenance teams without extra wiring.
In oil and gas workshops, water-treatment plants and port equipment the operating range from minus 40 to plus 85 degrees Celsius and the sealed shaft help the encoder tolerate heat, dust and washdown. For hazardous areas, check certification separately because this is a standard industrial product.
Mounting, wiring and commissioning of the AFM60A-S4IB018x12
Mount the encoder on its face mount flange and connect the 10 mm shaft through a flexible coupling; the shaft load limits are 80 N radial and 40 N axial. Supply 10 V to 30 V DC through the A-coded M12 male connector and connect the network through the D-coded M12 female sockets using CAT-5e cable. Fit mating connectors or blind caps so that the IP67 housing rating is retained.
Add the EDS file to the controller project, configure the number of steps and revolutions and set the PRESET value so the mechanical zero matches the machine reference. Verify the counting direction, then use the diagnostics data to confirm voltage and temperature margins.
Maintenance of SICK AFM60A-S4IB018x12
The bearing life of 3 x 10 to the 9th revolutions is the main wear limit. Check the coupling and the flange screws at planned shutdowns and watch the operating hours and motion counters in the diagnostics. Allow for self-heating of 3.3 K per 1,000 rpm in the temperature budget.
When replacing a unit, set the same parameters and re-establish the zero position with PRESET. Keep the code 1055334 in the maintenance record so the same interface is ordered.
Related items you may also need: SICK LFP1150-G1NMB LFP Inox Capacitive Level Sensor | SICK deTec4 Core Set 14/750 deTec Safety Light Curtain | SICK UM30-21311B UM30 Ultrasonic Sensor | All SICK products.
Documents and quotation
The manufacturer data sheet for the SICK AFM60A-S4IB018x12 accompanies this page and shows the dimension drawing and the connection details.
Send your RFQ with the part number AFM60A-S4IB018x12, the quantity and the delivery location in Oman or the GCC. Seven Star LLC will check availability of the SICK AFM60A-S4IB018x12, and couplings and connectors can be added to the same quotation.
Datasheets & Documents
- Datasheet SICK AFM60A-S4IB018x12 Multi-Turn Absolute Encoder, EtherNet/IP Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
SICK is the German maker of industrial sensors: photoelectric and proximity sensors, safety laser scanners and light curtains, encoders, distance sensors, code readers and gas analysers. Erwin Sick, an optics engineer, founded it in Munich in 1946, and in 1952 it introduced its first marketable accident-prevention light curtain, which protected press operators by stopping the machine when a hand broke the light beam. The company moved to Waldkirch in the Black Forest in 1956 and is still headquartered there. It is a privately held company, and has been an Aktiengesellschaft (AG) since 1996.
SICK company profile
| Founded | 1946, Munich, Germany, by Erwin Sick (1909–1988) |
|---|---|
| Headquarters | Waldkirch, Baden-Württemberg, Germany (since 1956) |
| Ownership | Privately held; after the founder's death in 1988 his widow Gisela Sick became the main shareholder. Legal form SICK AG since 1996 |
| Size | More than 12,000 employees and group revenue of about EUR 2.3 billion (company figures for 2023) |
| First breakthrough | Accident-prevention light curtain for presses, shown in Hanover in 1952 |
| International growth | First foreign subsidiary in France in 1972, United States in 1976; today sales and service companies worldwide |
| Product families | Photoelectric, inductive, capacitive, magnetic and ultrasonic sensors; safety laser scanners, light curtains, safety controllers and relays; encoders and motor feedback systems; distance sensors and LiDAR; barcode and 2D code readers and machine vision; gas analysers, dust and flow measurement for process and emissions monitoring |
Milestones
- 1946: Erwin Sick receives a licence to run his engineering firm in Munich.
- 1952: The first marketable accident-prevention light curtain is presented in Hanover and goes into series production.
- 1956: The company moves to Waldkirch with 25 employees.
- 1972 and 1976: Subsidiaries are founded in France and the United States.
- 1996: SICK becomes an Aktiengesellschaft.
- Today: Sensors for factory and logistics automation, machine safety and process analysis, with a large share of revenue outside Germany.
Choosing a SICK sensor
For object detection, the sensing principle comes first. A retro-reflective sensor (WL series) sends light to a reflector and switches when an object breaks the beam; it is reliable over long distances and easy to align. A sensor with background suppression (WTB series) detects an object at a set distance and ignores what is behind it, which suits conveyors with shiny or dark backgrounds. A through-beam pair (WS/WE) gives the longest range and the highest reliability in dust. For transparent bottles and film, use a model built for transparent objects (for example WL12G-3B or WL150-P420). The digits in the code also matter: "P" usually means a PNP output and "N" NPN, and the last digits set the connector or cable. For machine guarding, a safety laser scanner such as nanoScan3 or microScan3 protects an area, while a safety controller such as Flexi Soft combines several safety devices.
Where SICK products are used
In Oman and the GCC, SICK sensors are used in packaging and bottling lines, food and beverage plants, logistics and airport baggage handling, cement and steel plants, ports and cranes, automated warehouses, and on machines built by European OEMs. SICK safety scanners guard robots and automated guided vehicles, and its encoders give position feedback on motors, hoists and conveyors.
SICK products we list
| Family | Examples |
|---|---|
| Photoelectric sensors | WL12-3P2431, WTB12-3P2431, GTB6-P4211, VL18-4P3240, WL12G-3B2531, WS/WE100, KT5W contrast, W26 IO-Link |
| Proximity, cylinder and ultrasonic sensors | IME12-08NPSZC0S, IME18-05BPSZC0S, MZT8, UM18 4-20 mA, UM30, UFN3 fork |
| Machine safety | nanoScan3, microScan3, S300 Professional, Flexi Soft FX3-CPU1, FX3-XTIO, ReLy OSSD |
| Encoders and motor feedback | DFS60B, AFM60 PROFINET, AFS60 SSI, ATM60 PROFIBUS, SRS50, EFS50 |
| Distance sensors and code readers | DT50, DL50, DT35, Lector632 |
Ordering SICK products: what we need
Send the type code and the 7-digit SICK part number from the label (for example WTB12-3P2431 together with its part number). For a replacement sensor, add the output (PNP or NPN), connection (M8, M12 or cable) and sensing distance. For encoders, add the interface (incremental, SSI, PROFIBUS, PROFINET), resolution and shaft type. For safety scanners, tell us the model and whether the existing configuration needs to be kept.
Frequently requested SICK models: SICK WTB4-3 Miniature Photoelectric Proximity Sensor, SICK IME18-08NPSZW2K Inductive Proximity Sensor, SICK DT35-B15251 Laser Distance Sensor, SICK microScan3 Safety Laser Scanner, SICK RZT7-03ZUS-KWB T-Slot Cylinder Sensor.
Facts checked against SICK's published company history and annual figures, October 2026.
Browse SICK products by category: Sensors & Transmitters.
FAQ
Questions about the SICK AFM60A-S4IB018x12 Multi-Turn Absolute Encoder,
Answers from our engineering team on installation, compatibility and integration.
01What interface does the AFM60A-S4IB018x12 use?
It uses EtherNet/IP with encoder profile V4.1 class 3 at 10 or 100 Mbit/s and supports Device Level Ring.
02What resolution does the AFM60A-S4IB018x12 offer?
It provides 262,144 steps per revolution (18 bit) and 4,096 revolutions (12 bit), with error limits of 0.03 degrees.
03What connectors does the AFM60A-S4IB018x12 have?
It has one axial A-coded M12 male connector for power and two axial D-coded M12 female connectors for the network.
04What supply does the AFM60A-S4IB018x12 need?
It needs 10 V to 30 V DC and consumes 3 W or less without load.
05How long does the AFM60A-S4IB018x12 take to start?
The initialization time after switch-on is approximately 10 seconds, which should be allowed for in the start-up sequence.