Brand:

Hochiki YBN-R/4IS Intrinsically Safe Conventional Base

Description

Overview

Hochiki YBN-R/4IS is the intrinsically safe conventional mounting base that carries the Hochiki IS smoke detectors such as the SOC-E-IS photoelectric model. It contains no electronics at all. Its whole job is mechanical and electrical connection: it fixes to the ceiling, receives the field cable, and presents the contacts that the detector head plugs onto. Because it is the part that stays on the ceiling for the life of the installation, selecting the right base matters just as much as selecting the detector.

The base is only 8 mm high, which gives a very low profile once the detector is seated, and it is moulded in ABS in ivory or white. The marking printed on the base states that it is for intrinsically safe systems and must be used in accordance with the intrinsic safety certification. Seven Star LLC is an independent supplier serving Oman and the GCC.

Why choose Hochiki YBN-R/4IS

  • Electronics-free construction, so the base contributes no active components to the intrinsically safe loop.
  • Low profile of only 8 mm with a 100 mm diameter body.
  • Square cable clamps give a firm, vibration-resistant termination for conductors from 1 to 2.5 mm2.
  • A dedicated cable screen terminal keeps the screen continuity separate from the signal terminals.
  • Ordering codes cover ivory (YBN-R/4IS) and white (YBN-R/4IS(WHT)) finishes.
  • Rugged moulding that withstands handling during detector exchange and cleaning rounds.

Specification table for Hochiki YBN-R/4IS

Ordering codes YBN-R/4IS (ivory), YBN-R/4IS(WHT) (white)
Product type Intrinsically safe conventional detector mounting base
Colour and case material Ivory or white, ABS
Weight 51 g
Dimensions Diameter 100 mm, height 8 mm
Base fixing centres 48 to 74 mm
Maximum wire thickness 2.5 mm2
Maximum humidity 95 percent RH, non-condensing, at 40 degrees Celsius
Cable termination Square cable clamps
Screen termination Dedicated cable screen terminal
Electronics None

Terminal layout and wiring of YBN-R/4IS

The legend moulded on the base shows six numbered positions. Terminal 1 carries the positive line out together with the positive remote indicator line, terminal 2 is the positive line in, terminal 3 is earth, terminal 4 is the negative remote indicator connection, terminal 5 is the negative common out and terminal 6 is the negative common in. A wiring plan for a zone should therefore be drawn from the base legend, not copied from a base of a different range.

The maker states one wiring rule that deserves attention: this base does not maintain line continuity when the detector is removed. In practice, if manual call points are on the same zone, they should be wired onto the zone ahead of the detector bases so that removing a detector does not break the circuit to a call point. A zone drawing that places detectors first and call points last is a design error that the base itself will expose.

Compatibility and selection

The datasheet for the SOC-E-IS names the mounting base YBN-R/4(IS) as the compatible base, and the YBN-R/4IS datasheet states that it must be used with the intrinsically safe range of detectors. Do not substitute the ordinary YBN-R/3 conventional base in a hazardous-area loop, because that base belongs to the standard range. The two physical sizes look alike, which is exactly why a mix-up on site is plausible; check the base legend before the head is clipped on.

How Hochiki YBN-R/4IS differs from other Hochiki bases

Next to the conventional YBN-R/3 base, the YBN-R/4IS is the base certified for use with the intrinsically safe heads. Its fixing centres span 48 to 74 mm, covering most standard conduit boxes and ceiling fixings, while its height is 8 mm. The choice between ivory and white is purely cosmetic and follows the ceiling colour chosen by the architect or the plant standard.

Applications in Oman and the GCC

Intrinsically safe smoke detection with this base is found in ceiling voids of hydrocarbon processing facilities, battery rooms next to hazardous areas, paint and solvent stores, and fuel pump rooms. Utilities use the same philosophy in biogas digesters at wastewater plants, where methane makes an ordinary detector base unacceptable. Manufacturers who handle flammable powders or solvents also specify intrinsically safe loops for the detection layer above production halls.

Installation and commissioning

Fix the base on its 48 to 74 mm centres, strip each conductor to the length that the square clamp requires, and tighten the clamp screws firmly. Terminate the screen in the dedicated screen terminal and keep intrinsically safe and non-intrinsically safe wiring separated. Once all bases on the zone are wired, measure the loop with the detectors removed to check insulation and continuity, then fit the heads and test each one with an approved smoke test method.

Maintenance

The base needs little attention because it has no electronics. At each detector service, look at the clamps for corrosion or loosening, confirm that the screen terminal still holds, and replace any base with cracked plastic. Keep a spare base in stores for each colour you use so that a damaged ceiling base does not leave a zone without protection longer than necessary.

Ordering notes for Hochiki YBN-R/4IS

Please state the colour, quantity, and the detector model it will carry when requesting a quotation for Hochiki YBN-R/4IS. If you intend to supply a full hazardous-area zone, list the call points and barriers too, so that the complete set can be checked for compatibility before it ships to your site in Oman or elsewhere in the Gulf.

Related items you may also need: Hochiki ALN-EN Intelligent Photoelectric Smoke Sensor (ESP) | Hochiki CDX FIREbeam Conex Conventional Beam Smoke Detector | Hochiki ESP FIREbeam Xtra Addressable Beam Smoke Detector | All Hochiki products.

Documents and quotation

The manufacturer datasheet for YBN-R/4IS is available with this page and confirms the codes, dimensions, fixing centres and terminal data listed above. To obtain a quotation, send an RFQ with the part number Hochiki YBN-R/4IS and the quantity, together with the colour you need and the delivery location.

Datasheets & Documents
  • PDF Datasheet Hochiki YBN-R/4IS Intrinsically Safe Conventional Base Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Hochiki is a Japanese fire detection company, established in Tokyo in 1918 as Japan's first fire alarm manufacturer, with leading insurance companies among its founders. It makes smoke and heat detectors, beam detectors, addressable fire alarm systems and emergency lighting. Hochiki America has operated in the US since 1972.

Seven Star LLC is an independent supplier in Muscat. We list Hochiki detectors for fire alarm contractors in Oman and the GCC.

Hochiki company profile

Founded 1918, Tokyo, Japan
Founders Members of Japan's insurance industry
US operations Since 1972
Systems Conventional and addressable fire detection
Product families ESP intelligent detectors and multi-sensors, FIREbeam beam detectors, CDX conventional detectors, control panels

Milestones

  • 1918: Hochiki is founded in Tokyo.
  • 1972: Hochiki America begins US operations.

Hochiki product series

The ACD-EN is an intelligent multi sensor detector for Hochiki addressable systems.

Beam smoke detectors include the CDX FIREbeam Conex and CDX FIREbeam Xtra conventional detectors and the ESP FIREbeam Xtra addressable detector.

Multi sensor detectors combine smoke and heat sensing to detect different fire types and reduce false alarms. Beam detectors send an infrared beam across an open space and alarm when smoke reduces the signal, covering large areas with fewer devices.

Detectors must match the panel protocol and be installed and tested to the local fire code.

Where Hochiki detectors are used

Offices, hotels, schools and hospitals, and large open spaces such as warehouses, atriums and halls where beam detectors cover long distances.

Hochiki products we list

Family Examples
Fire & Gas Detectors ACD-EN Intelligent Multi Sensor, CDX FIREbeam Conex Conventional Beam Smo…, ESP FIREbeam Xtra Addressable Beam Smoke…

Ordering Hochiki detectors: what we need

Send the part number, protocol (conventional or ESP addressable), the beam range and the panel in use.

Facts checked against IFSEC Global centenary coverage and Hochiki company profiles, October 2026.

FAQ

Questions about the Hochiki YBN-R/4IS Intrinsically Safe Conventional

Answers from our engineering team on installation, compatibility and integration.

01Does the Hochiki YBN-R/4IS contain any electronics?
No. The datasheet describes it as electronics free, so it only provides mechanical mounting and terminal connection for the detector.
02What cable size can the YBN-R/4IS terminals accept?
The terminals accept conductors from 1 to 2.5 mm2 through square cable clamps, and a separate screen terminal is provided.
03Does removing the detector break the loop on YBN-R/4IS bases?
Yes. The base does not provide line continuity during detector removal, so call points should be wired onto the zone ahead of the detector bases.
04What are the physical dimensions of YBN-R/4IS?
The base is 100 mm in diameter and 8 mm high, weighs 51 g, and has fixing centres adjustable between 48 and 74 mm.
05Which colours of YBN-R/4IS exist?
The datasheet lists YBN-R/4IS in ivory and YBN-R/4IS(WHT) in white; both are moulded in ABS.