Hochiki CHQ-WS2 Addressable Loop-Powered Wall Sounder
Description
Overview
An alarm that cannot be heard is no alarm, and the Hochiki CHQ-WS2 is Hochiki’s loop-powered addressable wall sounder for making sure it is. It sits on the same ESP loop as the detectors, takes its address from the loop, and offers 51 selectable tones with an output adjustable from 90 to 102 dB(A) at one metre. Seven Star LLC is an independent supplier serving Oman and the GCC. This red unit suits corridors, stairwells, plant rooms and offices where an addressable sounder is preferred to a conventional one on a separate circuit.
Sound output and tones of the Hochiki CHQ-WS2
The sounder offers 51 user-selectable tones, and the datasheet states that all of them are compatible with EN 54-3. The tone frequency range runs from 300 to 2850 Hz. Output is variable between 90 and 102 dB(A), plus or minus 2 dB(A), measured at 1 metre with a supply of 24 V DC or above, and the sounding current scales with it, from about 2 mA at 90 dB(A) to about 8 mA at 102 dB(A). An auto shutdown mode lets the user set a fixed time after which the sounder silences itself, which limits noise pollution on false or minor events.
Technical specification of Hochiki CHQ-WS2
| Parameter | Datasheet value |
|---|---|
| Ordering codes | CHQ-WS2 red; CHQ-WS2(WHT) white; CHQ-WPK weatherproof kit |
| Operating voltage | 17 to 41 V DC |
| Quiescent current | 150 microamps with YBO-R/3(RED); 200 microamps with YBO-R/SCI(RED) |
| Sounding current | 2 mA at 90 dB(A) up to 8 mA at 102 dB(A) |
| Sound output at 1 m | 90 to 102 dB(A), plus or minus 2 dB(A), at 24 V DC or above |
| Number of tones | 51 |
| Tone frequency range | 300 to 2850 Hz |
| Operating temperature | minus 10 to plus 50 degrees C |
| Storage temperature | minus 30 to plus 70 degrees C |
| Humidity | 95 percent RH non-condensing at 40 degrees C |
| Ingress protection | IP21; IP65 with the weatherproof kit |
| Base fixing centres | 48 to 74 mm |
| Material | PC ABS, red or white |
| Weight and size | 152 g; diameter 112 mm, depth 67 mm |
How the Hochiki CHQ-WS2 differs from other Hochiki sounder options
The CHQ-WS2 is a wall sounder that fits the standard base YBO-R/3(RED) or the isolator base YBO-R/SCI(RED). It differs from the beacon-fitted and sounder-base families in that its role is audible warning only, at up to 102 dB(A), with 51 tones. The white variant, CHQ-WS2(WHT), has the same electronics and a different colour. The quiescent current rises from 150 to 200 microamps when the isolator base is used, which matters for loop current budgets with many devices. The IP21 rating is for indoor use; outdoor or damp areas need the CHQ-WPK weatherproof kit, which adds a back box and gasket set and lifts protection to IP65.
Where it is used in Oman and the GCC
Addressable sounders are common in schools, hotels, hospitals, office towers and industrial administration blocks. Because each sounder has its own loop address, the panel can sound selected floors or zones, sound a different tone for evacuation and alert, and report a fault for one device without silencing the rest. In industrial plants the sounders can be set to a high output in noisy areas and a lower one in offices. For washdown areas, covered walkways or semi-outdoor locations, add the weatherproof kit.
Selection and design notes
Check the sound pressure level needed at the bedhead or the farthest point of the room, which is often set by the standard applied, and then set the output and tone accordingly. Keep in mind that the quoted output is at one metre, so distance and walls reduce what the occupant hears. Match the base to the loop design: the standard base for a plain sounder or the isolator base where each device is to be isolated. Confirm the control panel supports addressable sounders of the ESP family and the tones you plan to use.
Installation and commissioning
Fit the base, connect the loop, and push the sounder onto the base so that it locks. The address is set using the TCH-B100 hand held programmer, as the datasheet states. Choose a tone and volume, run a sound test from the panel and measure the level on site with a calibrated meter if the project requires. When using the weatherproof kit, assemble the back box and gasket set as instructed and check the seal.
Maintenance
Test every sounder at each service, check that the grille is clear of paint, dust and insects, and confirm the tone programmed matches the design record. Replace any unit that gives a reduced output.
Planning loop current for sounders
A sounder draws far more current when active than a detector, so the loop calculation has to include the sounders on the loop at their chosen output, not just their quiescent current. At 102 dB(A) each unit takes about 8 mA, and fifty of them sounding together would draw 400 mA, which is a heavy load for any loop. Many designers lower the volume to a level that still meets the required sound pressure, divide the sounders among several loops, or add a separate supply. Check the loop capacity in the panel documentation and keep a reserve for future additions.
Auto shutdown and nuisance control
The auto shutdown mode deserves a note in the design. When a time limit is set, the sounder stops by itself after that period, which protects neighbours and occupants from long-running alarms in a building with no staff on site. It must not conflict with the evacuation strategy of the project, so confirm the setting with the fire engineer and record it, and test it during commissioning.
Ordering notes for Hochiki CHQ-WS2
State the colour and the base, and add the weatherproof kit when the location needs it. The programmer for setting the address is a separate item.
Related items you may also need: Hochiki CDX FIREbeam Xtra Conventional Beam Smoke Detector | Hochiki ESP FIREbeam Xtra Addressable Beam Smoke Detector | Hochiki ACD-EN Intelligent Multi Sensor | All Hochiki products.
Documents and quotation
The manufacturer datasheet for the Hochiki CHQ-WS2 is attached to this page. Send your RFQ with the part number, colour, quantity and delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet Hochiki CHQ-WS2 Addressable Loop-Powered Wall Sounder Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Hochiki is a Japanese fire detection company, established in Tokyo in 1918 as Japan's first fire alarm manufacturer, with leading insurance companies among its founders. It makes smoke and heat detectors, beam detectors, addressable fire alarm systems and emergency lighting. Hochiki America has operated in the US since 1972.
Seven Star LLC is an independent supplier in Muscat. We list Hochiki detectors for fire alarm contractors in Oman and the GCC.
Hochiki company profile
| Founded | 1918, Tokyo, Japan |
|---|---|
| Founders | Members of Japan's insurance industry |
| US operations | Since 1972 |
| Systems | Conventional and addressable fire detection |
| Product families | ESP intelligent detectors and multi-sensors, FIREbeam beam detectors, CDX conventional detectors, control panels |
Milestones
- 1918: Hochiki is founded in Tokyo.
- 1972: Hochiki America begins US operations.
Hochiki product series
The ACD-EN is an intelligent multi sensor detector for Hochiki addressable systems.
Beam smoke detectors include the CDX FIREbeam Conex and CDX FIREbeam Xtra conventional detectors and the ESP FIREbeam Xtra addressable detector.
Multi sensor detectors combine smoke and heat sensing to detect different fire types and reduce false alarms. Beam detectors send an infrared beam across an open space and alarm when smoke reduces the signal, covering large areas with fewer devices.
Detectors must match the panel protocol and be installed and tested to the local fire code.
Where Hochiki detectors are used
Offices, hotels, schools and hospitals, and large open spaces such as warehouses, atriums and halls where beam detectors cover long distances.
Hochiki products we list
| Family | Examples |
|---|---|
| Fire & Gas Detectors | ACD-EN Intelligent Multi Sensor, CDX FIREbeam Conex Conventional Beam Smo…, ESP FIREbeam Xtra Addressable Beam Smoke… |
Ordering Hochiki detectors: what we need
Send the part number, protocol (conventional or ESP addressable), the beam range and the panel in use.
Facts checked against IFSEC Global centenary coverage and Hochiki company profiles, October 2026.
Browse Hochiki products by category: Fire & Gas Detectors.
FAQ
Questions about the Hochiki CHQ-WS2 Addressable Loop-Powered Wall
Answers from our engineering team on installation, compatibility and integration.
01How loud is the Hochiki CHQ-WS2?
Output is variable from 90 to 102 dB(A), plus or minus 2 dB(A), at one metre with a 24 V DC supply or above.
02How many tones does the Hochiki CHQ-WS2 offer?
It offers 51 user-selectable tones, all stated as EN 54-3 compatible, in a frequency range of 300 to 2850 Hz.
03What IP rating does the Hochiki CHQ-WS2 have?
It is rated IP21 for indoor use and reaches IP65 when fitted with the CHQ-WPK weatherproof kit.
04Which bases fit the Hochiki CHQ-WS2?
It fits the standard base YBO-R/3(RED) or the isolator base YBO-R/SCI(RED), with fixing centres of 48 to 74 mm.
05How is the Hochiki CHQ-WS2 addressed?
It has a single loop address set with the TCH-B100 hand held programmer, and it is loop powered from 17 to 41 V DC.