Brand:

Honeywell STF73P SmartLine STF700 Flange Level Transmitter 100 psi

Description

STF73P at a glance

Honeywell STF73P combines a 316L stainless steel flange with the 100 psi (7.0 bar) STF700 meter body. It is the answer for tall tanks, towers or dense-liquid vessels where hydrostatic pressure exceeds 400 inH2O but a heavy carbon-steel extended diaphragm assembly is not needed.

The datasheet gives a minimum span of 1 psi (0.07 bar), a total performance figure of only 0.167 percent of span at 20 psi, and a weight of 14 to 19 lb (6.4 to 8.7 kg). Stability is 0.03 percent of URL per year.

STF73P key attributes

  • Range minus 100 to plus 100 psi (minus 7.0 to plus 7.0 bar), minimum span 1 psi (0.07 bar).
  • 316L stainless steel process-wetted mounting flange, 2 or 3-inch Class 150 ANSI.
  • Temperature effect 0.070 plus 0.015 times URL over span per 28 degC.
  • Static pressure effect 0.032 plus 0.005 times URL over span per 300 psi.
  • Total performance 0.167 percent of span at 20 psi.

Technical data for STF73P

Parameter Value
Model STF73P (STF700 SmartLine flange-mounted)
Upper / lower range limit 100 psi (7.0 bar) / -100 psi (-7.0 bar)
Minimum span 1 psi (0.07 bar)
Maximum turndown 100:1
Accuracy (standard / optional) 0.05 / 0.040 percent of span
Stability 0.03 percent of URL per year, ten years
Reference turndown / knee C 4:1 / 25 psi (1.75 bar)
Temperature effect 0.070 + 0.015 x URL/span, percent of span per 28 degC
Static pressure effect 0.032 + 0.005 x URL/span, percent of span per 300 psi
Total performance example 0.167 percent of span at 20 psi
Flange 2 or 3-inch ANSI Class 150, 316L stainless steel
MAWP 230 psi (15.9 bar) at -29 to 38 degC; 185 psi (12.8 bar) at 125 degC meter body
Net weight 14 to 19 lb (6.4 to 8.7 kg) with aluminium housing
Output / protocol Two-wire 4 to 20 mA with Honeywell HART 7
Supply voltage and loop load 10.8 to 42.4 VDC at the terminals; load 0 to 1,440 ohms
Response time 100 ms; damping 0 to 32 s, default 0.50 s; turn-on 2.5 s
Rated ambient / meter body temperature -40 to 85 degC / -40 to 110 degC (operative limit 125 degC)
Process head connection 1/4-inch NPT, 1/2-inch NPT with adapter, DIN options
Fill fluid Silicone 200 or CTFE
Housing Polyester powder-coated low-copper aluminium, Type 4X / IP66 / IP67; stainless housing optional
Overpressure / no-burst 1.5 x MAWP; no-burst 3 x MAWP up to 2,000 psi, 2.5 x MAWP + 1,000 psi above

STF73P compared with the other STF700 models

Relative to the STF72P the STF73P offers a 100 psi range with a 4:1 reference turndown instead of 16:1, and a stability of 0.03 percent per year instead of 0.02. The temperature term is 0.070 plus 0.015 versus 0.055 plus 0.025 and the static term 0.032 plus 0.005 versus 0.030 plus 0.007.

Relative to the STF735 the STF73P is much more thermally stable (0.167 percent versus 0.514 percent at 20 psi in the datasheet examples) but cannot take extended diaphragms, DIN flanges or Class 300 flanges.

Model URL Temp effect D + E Total performance
STF72P 400 inH2O 0.055 + 0.025 0.191% at 80 inH2O
STF73P 100 psi 0.070 + 0.015 0.167% at 20 psi
STF735 100 psi 0.080 + 0.080 0.514% at 20 psi

Level and pressure duties for STF73P

The STF73P is ideal for process vessels at moderate temperature where stainless steel is mandatory: brine, seawater, mild acids and food-grade liquids. In Oman it can be found on desalination post-treatment tanks, firewater storage and chemical dosing day tanks.

For tall tanks, its range allows level spans of up to about 70 metres of water, much more than most plants need.

Because a flanged transmitter reads hydrostatic pressure, density changes show up as level error. Where product density varies between batches, the 1 psi (0.07 bar) minimum span gives enough resolution to apply a density correction in the control system, using the HART digital value rather than the analog output when higher resolution is wanted.

Choosing the right STF73P configuration

Use the STF73P if the nozzle is 2 or 3-inch Class 150 and the working pressure remains below 230 psi (15.9 bar). If the vessel is hot above 125 degC, move to the STF735 with extended diaphragm. The fill options are silicone 200 or CTFE.

Confirm the zero suppression needed when the transmitter is mounted below the tank tap.

Installing and starting up STF73P

Mount on the nozzle with the supplied gasket, tighten bolts in a cross pattern, then connect the low side port to the vapour phase of closed tanks. Use a bracketless installation for short nozzles but support long nozzles.

Power from 10.8 to 42.4 VDC, set range by display or HART.

Maintenance and diagnostics

Rinse the diaphragm during outages; verify every two years; keep a spare electronics module.

STF73P: buyer questions

What range does the Honeywell STF73P have? It covers minus 100 to plus 100 psi (minus 7.0 to plus 7.0 bar) with a minimum span of 1 psi (0.07 bar).

What flange is used on the STF73P? A 2 or 3-inch ANSI Class 150 flange in 316L stainless steel that is process wetted.

What is the total performance of the STF73P? 0.167 percent of span at 20 psi with 5:1 turndown and a 28 degC shift, from the datasheet example.

Is the STF73P suitable for hot service? The datasheet gives no process interface temperature rating for the STF73P; use the STF735 for hot process interface temperatures.

What is the weight of the STF73P? 14 to 19 lb (6.4 to 8.7 kg) with aluminium housing.

Documents and quotation

Specification 34-ST-03-123 is available on request.

To request a quotation for Honeywell STF73P, send part number, quantity, flange size and approval to Seven Star LLC.

What to Include in Your Honeywell STF73P Enquiry

An accurate quotation for the Honeywell STF73P depends on a few details. Please share the complete part number, any suffix codes for options or approvals, the operating conditions at the installation point, and whether certificates of conformity or test reports must ship with the goods. It also helps to know whether the unit is for planned maintenance, a shutdown or an urgent breakdown, because that decides how it is sourced and shipped. With this information our team can check compatibility with your existing hydrostatic & dp level transmitters and reply with availability and a realistic delivery estimate.

Spares and Lifecycle Considerations

For critical service, many plants hold one Honeywell STF73P as an operational spare rather than waiting for a failure. When you plan spares, look at how many identical hydrostatic & dp level transmitters units are installed, how long a replacement would take to arrive, and the cost of an unplanned stop. Store spare units in their original packaging in a dry, temperature-controlled area and record the part number and serial number in your maintenance system. We can quote single units or a small spares package and confirm the lead time for each item in writing.

Other Models in the STF700 Range

Seven Star LLC supplies models from the STF700 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Honeywell STF725 SmartLine STF700 Flange Mount Level TransmitterHydrostatic & DP Level TransmittersView details
Honeywell STF735 SmartLine STF700 Flange Mount Level TransmitterHydrostatic & DP Level TransmittersView details
Honeywell STF72P SmartLine STF700 Flange Level Transmitter 316LHydrostatic & DP Level TransmittersView details
Honeywell STF73P SmartLine STF700 Flange Level Transmitter 100 psiHydrostatic & DP Level TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Honeywell STF73P SmartLine STF700 Flange Level Transmitter 100 psi Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell STF73P SmartLine STF700 Flange Level

Answers from our engineering team on installation, compatibility and integration.

01What range does the Honeywell STF73P have?
It covers minus 100 to plus 100 psi (minus 7.0 to plus 7.0 bar) with a minimum span of 1 psi (0.07 bar).
02What flange is used on the STF73P?
A 2 or 3-inch ANSI Class 150 flange in 316L stainless steel that is process wetted.
03What is the total performance of the STF73P?
0.167 percent of span at 20 psi with 5:1 turndown and a 28 degC shift, from the datasheet example.
04Is the STF73P suitable for hot service?
The datasheet gives no process interface temperature rating for the STF73P; use the STF735 for hot process interface temperatures.
05What is the weight of the STF73P?
14 to 19 lb (6.4 to 8.7 kg) with aluminium housing.