Endress+Hauser FMB50 Deltapilot M Hydrostatic Level Transmitter
Description
Endress+Hauser FMB50 Deltapilot M compact hydrostatic level transmitter
The Endress+Hauser FMB50 is the compact member of the Deltapilot M family. It is a gauge pressure transmitter with a metallic process diaphragm that screws, flanges or clamps directly onto the tank wall or a pipe stub, and it converts the hydrostatic pressure of the liquid above it into a level, volume or mass reading. Unlike the FMB51, FMB52 and FMB53, which hang into the liquid, the FMB50 sits at a fixed tapping point, so it suits tanks with a connection below the lowest level.
Seven Star LLC supplies the FMB50 in Oman and the GCC as an independent supplier in Muscat. The sections below explain what the FMB50 offers, how its measuring cell works and what we need from you to quote the right version.
FMB50 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Endress+Hauser / FMB50 (Deltapilot M) |
| Measured variable | Hydrostatic pressure, used for level, volume or mass in liquids and paste-like media |
| Measuring cells (URL) | 100 mbar, 400 mbar, 1.2 bar, 4 bar or 10 bar (1.5 to 150 psi); lower range limit –0.1 to –1 bar depending on the cell |
| Overpressure limit (OPL) | 4, 8, 24, 24 and 40 bar for the five cells respectively; the process connection may lower this |
| Reference accuracy | ±0.2 % standard; platinum option from ±0.15 % down to ±0.1 % of the calibrated span, depending on cell and turn down |
| Turn down | Up to 20:1 can be set at the factory; higher on request |
| Process temperature | –10 to +100 °C; 135 °C allowed for 30 minutes at most |
| Ambient temperature | –40 to +85 °C without display; –20 to +70 °C with display |
| Process diaphragm | Alloy C276 (2.4819), 35.8 mm diameter; optional gold-rhodium coating |
| Output / communication | 4 to 20 mA with HART 6.0, 4 to 20 mA with IO-Link (FMB50 only), PROFIBUS PA or FOUNDATION Fieldbus |
| Supply voltage | HART 11.5 to 30 V DC intrinsically safe, 11.5 to 45 V DC otherwise; IO-Link 18 to 30 V DC; PA and FF 9 to 32 V DC (non-hazardous) |
| Housing | F31 aluminium or F15 stainless steel (hygienic); IP66/68 NEMA 4X/6P depending on cable entry |
| Functional safety | 4 to 20 mA version assessed to IEC 61508 and IEC 61511 for use up to SIL 2 |
These values come from the Endress+Hauser technical information for the Deltapilot M FMB50 to FMB53 series. Exact limits depend on the measuring cell, process connection and options chosen, so always check the nameplate code of the version you quote.
How the FMB50 CONTITE measuring cell works
A liquid column produces a pressure that is proportional to its height and density. The FMB50 senses that pressure on its process diaphragm and passes it, through an oil fill, to a silicon measuring element. The element sits between the process diaphragm and a second, rear diaphragm, which is the idea behind the CONTITE cell: the sensing element is sealed off from the outside air, so condensation and aggressive gases in the vent path cannot reach it.
The electronics correct the signal with the cell temperature, and a linearization table of up to 32 points can be entered on site or remotely. That table lets the FMB50 output a linear level in a spherical, horizontal cylindrical or cone-bottom vessel instead of a raw pressure. For tanks under gas pressure, two transmitters and a PLC can work out level from the pressure difference.
FMB50 process connections and hygienic adapters
The FMB50 is available with a G 1½ A thread (316L, with an Alloy C276 bottom section in one variant) and a 1½ MNPT thread, each weighing about 0.8 kg. EN, ASME and JIS flanges are offered, and hygienic users can choose from a long list: DIN 11851, Tri-Clamp, Varivent type N, SMS 2 in, NEUMO D50, DRD 65 mm, the universal process adapter and Anderson adapters. Wetted hygienic parts have surface roughness Ra below 0.76 µm as standard.
Because the overpressure rating of the connection can be lower than that of the cell, the datasheet states that the device is set at the factory to the lower value. If you need the full cell range, pick a connection with a higher rating.
Where the FMB50 fits and related Deltapilot M models
The Deltapilot M family covers four mounting styles that share one electronics platform. The FMB50 is the external, wall-mounted version. The FMB51 is a rod version for open tanks and sumps, the FMB52 is a cable version with a threaded or flanged top connection, and the FMB53 is a cable probe hung from a suspension clamp with the housing mounted separately. If the vessel has no connection below the lowest level and you have to measure from above, one of those three is the better fit. For high accuracy up to SIL 3, the Deltapilot S FMB70 is the sibling to look at, and for plain process pressure the Cerabar family such as the PMP11 serves instead.
Selecting and ordering an FMB50
- Measuring cell: choose the cell so the maximum hydrostatic pressure, plus any top pressure, stays within its range. A hydrostatic head of 600 mbar plus 300 mbar of top pressure needs a cell of at least 1.2 bar.
- Turn down: a smaller span lowers the accuracy; the datasheet gives a formula for each cell, so set the span as close to the real level range as practical.
- Output: HART for most plants, PROFIBUS PA or FOUNDATION Fieldbus for fieldbus segments, and IO-Link where the FMB50 connects to a sensor master. IO-Link is not available on the FMB51 to FMB53.
- Process connection and diaphragm: match the thread, flange or hygienic fitting to the vessel and pick Alloy C276 plain or gold-rhodium coated, which protects against hydrogen diffusion in aqueous solutions.
- Fill fluid: inert oil or the synthetic food-grade oil; oxygen cleaning and paint-wetting-free cleaning are available as service options.
- Approvals: the datasheet lists ATEX, IECEx, FM, CSA and NEPSI as families of Ex approvals, plus ASME BPE conformity for the FMB50 only. Confirm the exact one for your area when we quote.
FMB50 installation, commissioning and maintenance
Mount the FMB50 below the lowest measuring point and keep it out of the filling curtain, the tank outflow and any zone hit by agitator pulses. A shutoff valve in front of the transmitter makes calibration and functional checks easier. For liquids that harden when cold, include the device in the tank insulation. In gas service, fit it above the tapping point so condensate drains back, and on steam use a siphon.
The orientation influences zero, so the unit is preset at the factory and any remaining position shift can be corrected with the keys on the electronics or by digital command. Commissioning is menu driven with guided application menus, and the 4 to 20 mA test signal can be measured at the test terminals without breaking the loop. In service, check the diaphragm for build-up on sticky media and keep the cable entry seal and cover tight, because the housing rating depends on them.
Typical FMB50 applications in Oman and the GCC
In Oman and the GCC the FMB50 is a common choice for day tanks and storage tanks of water, treated water and chemicals in desalination and water treatment plants, for cooling water and condensate vessels in power stations, and for utility tanks in oil and gas and petrochemical sites. Gulf sites bring strong sun, dust and salt air, so the stainless F15 housing, a proper cable gland and a sunshade for tanks in full sun are worth specifying. Hygienic fittings suit food, beverage and pharmaceutical lines.
Information to send with an FMB50 RFQ
- Part number FMB50 and, if known, the full order code from the nameplate or an existing unit.
- Medium, density range and the lowest and highest level, or the span in mbar or bar.
- Process temperature, any top pressure or vacuum, and cleaning or steam-out conditions.
- Required output (HART, PROFIBUS PA, FOUNDATION Fieldbus or IO-Link) and supply.
- Process connection type and size, diaphragm material and hazardous-area classification.
- Required certificates such as 3.1 material or calibration, and quantity.
Documents and quotation
A copy of the Endress+Hauser technical information covering the Deltapilot M FMB50, FMB51, FMB52 and FMB53 is attached on this page, so you can check ranges, connections and options before ordering.
Send us the FMB50 specification above and Seven Star LLC will prepare a quotation for delivery to Oman and the GCC.
Other Models in the Eh Deltapilot M Range
Seven Star LLC supplies models from the Eh Deltapilot M range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser FMB50 Deltapilot M Hydrostatic Level Transmitter | Level Instrumentation | You are viewing this model |
| Endress+Hauser FMB51 Deltapilot M Rod Level Transmitter | Level Instrumentation | View details |
| Endress+Hauser FMB52 Deltapilot M Cable Level Transmitter | Level Instrumentation | View details |
| Endress+Hauser FMB53 Deltapilot M Suspended Cable Transmitter | Level Instrumentation | View details |
Datasheets & Documents
- Datasheet Endress+Hauser FMB50 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser FMB50 Deltapilot M Hydrostatic Level
Answers from our engineering team on installation, compatibility and integration.
01What is the Endress+Hauser FMB50 used for?
The FMB50 is a compact hydrostatic transmitter that measures liquid level, volume or mass from the pressure at a tapping point below the liquid. It mounts on a thread, flange or hygienic fitting on the tank or pipe.
02What measuring ranges does the FMB50 offer?
Five measuring cells are available: 100 mbar, 400 mbar, 1.2 bar, 4 bar and 10 bar. Overpressure limits run from 4 to 40 bar, but the process connection can lower the usable value.
03Which outputs does the FMB50 support?
It offers 4 to 20 mA with HART, PROFIBUS PA, FOUNDATION Fieldbus and IO-Link. IO-Link is exclusive to the FMB50 within the FMB50 to FMB53 group.
04What is the process temperature limit of the FMB50?
The process temperature may be –10 to +100 °C, with up to 135 °C for a maximum of 30 minutes. The ambient range is –40 to +85 °C without a display.
05How does the FMB50 differ from the FMB51, FMB52 and FMB53?
The FMB50 is mounted at the vessel wall, while the FMB51 uses a rod and the FMB52 and FMB53 use cables that hang in the liquid. The FMB50 also has the widest range of hygienic process connections and the IO-Link option.


















Reviews
There are no reviews yet.