Brand: Honeywell
Honeywell STF735 SmartLine STF700 Flange Mount Level Transmitter
Description
STF735 at a glance
Honeywell STF735 is the higher-range flange-mounted transmitter of the STF700 family, with 100 psi (7.0 bar) upper and minus 100 psi lower limits and a minimum span of 1 psi (0.07 bar). Where an STF725 saturates on tall tanks or dense liquids, the STF735 keeps going: 100 psi of hydrostatic head equals roughly 70 metres of water.
It uses the same flange and extended diaphragm options as the STF725 and the same HART 7 electronics; only the meter body differs. Stability is given as 0.03 percent of URL per year, slightly higher than the 0.02 of the 400 inH2O models.
STF735 key attributes
- Range minus 100 to plus 100 psi (minus 7.0 to plus 7.0 bar); minimum span 1 psi (0.07 bar).
- Accuracy 0.05 percent of span standard with 0.040 percent optional.
- Reference turndown 4:1, knee C of 25 psi (1.75 bar).
- Temperature effect 0.080 plus 0.080 times URL over span per 28 degC.
- Static pressure effect 0.110 plus 0.0125 times URL over span per 300 psi.
- Same flush and 2, 4 or 6-inch extended diaphragm choices as the STF725.
Technical data for STF735
| Parameter | Value |
|---|---|
| Model | STF735 (STF700 SmartLine flange-mounted) |
| Upper / lower range limit | 100 psi (7.0 bar) / -100 psi (-7.0 bar) |
| Minimum span | 1 psi (0.07 bar) |
| Maximum turndown | 100:1 |
| Accuracy (standard / optional) | 0.05 / 0.040 percent of span |
| Stability | 0.03 percent of URL per year, ten years |
| Reference turndown / knee C | 4:1 / 25 psi (1.75 bar) |
| Temperature effect | 0.080 + 0.080 x URL/span, percent of span per 28 degC |
| Static pressure effect | 0.110 + 0.0125 x URL/span, percent of span per 300 psi |
| Total performance example | 0.514 percent of span at 20 psi, 5:1 turndown |
| Flange options | 2, 3 or 4-inch ANSI 150 or 300; DN50, DN80, DN100 PN40 |
| Extended diaphragm | 2, 4 or 6 inches (50, 101 or 152 mm) |
| Net weight | 18 to 32 lb (8.2 to 14.5 kg) with aluminium housing |
| Output / protocol | Two-wire 4 to 20 mA with Honeywell HART 7 |
| Supply voltage and loop load | 10.8 to 42.4 VDC at the terminals; load 0 to 1,440 ohms |
| Response time | 100 ms; damping 0 to 32 s, default 0.50 s; turn-on 2.5 s |
| Rated ambient / meter body temperature | -40 to 85 degC / -40 to 110 degC (operative limit 125 degC) |
| Process head connection | 1/4-inch NPT, 1/2-inch NPT with adapter, DIN options |
| Fill fluid | Silicone 200 or CTFE |
| Housing | Polyester powder-coated low-copper aluminium, Type 4X / IP66 / IP67; stainless housing optional |
| Overpressure / no-burst | 1.5 x MAWP; no-burst 3 x MAWP up to 2,000 psi, 2.5 x MAWP + 1,000 psi above |
STF735 compared with the other STF700 models
Between the STF735 and STF725 the key difference is the full-scale pressure: 100 psi against 400 inH2O (about 14.5 psi). Equally important are the coefficients: the STF735 has an E temperature coefficient of 0.080 versus 0.045, and a reference turndown of 4:1 versus 16:1. For a 20 psi level span the datasheet gives total performance of 0.514 percent.
The STF73P is the flush-flange sibling of the STF735 in the same 100 psi range, with a much smaller temperature effect of 0.070 plus 0.015 and total performance of 0.167 percent at 20 psi, but with the restriction to 2 or 3-inch Class 150 flanges in 316L stainless steel.
| Model | URL | Total performance example | Stability |
|---|---|---|---|
| STF725 | 400 inH2O | 0.536% at 80 inH2O | 0.02 |
| STF735 | 100 psi | 0.514% at 20 psi | 0.03 |
| STF73P | 100 psi | 0.167% at 20 psi | 0.03 |
Level and pressure duties for STF735
Typical STF735 duties include deep process columns and tall storage spheres, boiler drum level on low-pressure steam systems, and high-density slurry tanks, where the hydrostatic pressure of the liquid exceeds the range of the 400 inH2O unit.
In the GCC, desalination brine tanks, acid storage and fertiliser plant vessels are typical, with the extended diaphragm preventing scale accumulation in the nozzle.
Choosing the right STF735 configuration
Compute the span in psi from liquid height times specific gravity times 0.0361 psi per inch of water; if it exceeds 400 inH2O (14.5 psi), the STF735 is needed. Match the flange to the nozzle, check the flange rating at your process temperature (for example Class 150 carbon steel 245 psi at maximum meter body temperature of 125 degC) and choose silicone or CTFE fill by temperature and medium.
The transmitter housing is rated Type 4X, IP66 and IP67, which suits outdoor tank farms.
Installing and starting up STF735
Because the transmitter is heavy at 18 to 32 lb, support it per the installation manual if the nozzle is long. After installing, zero the transmitter with the tank empty or with the fluid at the lower tap, and enter the fill fluid specific gravity so that remote flange offsets are handled.
Apply 10.8 to 42.4 VDC, confirm the 4 to 20 mA output and check the display.
Maintenance and diagnostics
Cleaning the diaphragm is the main maintenance task; unbolt the flange when the tank is out of service and rinse carefully without scratching the diaphragm. Verify every two years.
STF735: buyer questions
What is the range of the Honeywell STF735? Minus 100 to plus 100 psi (minus 7.0 to plus 7.0 bar) with a minimum span of 1 psi (0.07 bar).
How does the STF735 differ from the STF725? The STF735 spans 100 psi instead of 400 inH2O and has a 4:1 reference turndown, a 0.03 percent per year stability figure and different temperature coefficients.
Does the STF735 support extended diaphragms? Yes, the datasheet lists extended diaphragm lengths of 2, 4 or 6 inches (50, 101 or 152 mm) as well as flush.
What is the STF735 total performance? The datasheet example gives 0.514 percent of span at 20 psi with 5:1 turndown and a 28 degC shift.
What housing rating does the STF735 have? The housing meets Type 4X, IP66 and IP67 and is polyester powder-coated aluminium, with all-stainless housing optional.
Documents and quotation
Specification 34-ST-03-123 covers the STF735 and the other STF700 models and is available with a quote.
To obtain a quotation for Honeywell STF735, send part number, quantity, flange class and size, extension and approval to Seven Star LLC.
Installation and Commissioning Planning
Planning ahead shortens downtime when a Honeywell STF735 goes into service. Confirm the available mounting space, cable entry or process connection, and the tools and spare seals needed on the day. Keep the existing configuration or calibration data so the new unit can be set up to match, and check that loop drawings and the asset register are updated after the swap. If the installation has to fit a short shutdown window, tell us the date when you request a quotation so that delivery of the Honeywell equipment can be planned around it.
Other Models in the STF700 Range
Seven Star LLC supplies models from the STF700 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell STF725 SmartLine STF700 Flange Mount Level Transmitter | Hydrostatic & DP Level Transmitters | View details |
| Honeywell STF735 SmartLine STF700 Flange Mount Level Transmitter | Hydrostatic & DP Level Transmitters | You are viewing this model |
| Honeywell STF72P SmartLine STF700 Flange Level Transmitter 316L | Hydrostatic & DP Level Transmitters | View details |
| Honeywell STF73P SmartLine STF700 Flange Level Transmitter 100 psi | Hydrostatic & DP Level Transmitters | View details |
Datasheets & Documents
- Datasheet Honeywell STF735 SmartLine STF700 Flange Mount Level Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell STF735 SmartLine STF700 Flange Mount
Answers from our engineering team on installation, compatibility and integration.
01What is the range of the Honeywell STF735?
Minus 100 to plus 100 psi (minus 7.0 to plus 7.0 bar) with a minimum span of 1 psi (0.07 bar).
02How does the STF735 differ from the STF725?
The STF735 spans 100 psi instead of 400 inH2O and has a 4:1 reference turndown, a 0.03 percent per year stability figure and different temperature coefficients.
03Does the STF735 support extended diaphragms?
Yes, the datasheet lists extended diaphragm lengths of 2, 4 or 6 inches (50, 101 or 152 mm) as well as flush.
04What is the STF735 total performance?
The datasheet example gives 0.514 percent of span at 20 psi with 5:1 turndown and a 28 degC shift.
05What housing rating does the STF735 have?
The housing meets Type 4X, IP66 and IP67 and is polyester powder-coated aluminium, with all-stainless housing optional.