Brand:

Yokogawa PH8ERP-05-TN-N-E KCl Refillable pH Sensor

Description

PH8ERP-05-TN-N-E, the simple refillable pH sensor

Not every pH loop needs a reserve tank. In clean, mild, open tanks a refillable reference is perfectly adequate, cheaper to install and has fewer parts to leak. Yokogawa PH8ERP-05-TN-N-E is that sensor: the KCl refillable type of the PPS-bodied PH8 range, coded for a 5 m cable, titanium solution ground and the E measuring system for the FLXA family. Its range, pH 2 to 12 up to 80 C, covers most water and effluent duties.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Design features

  • Reinforced PPS resin body, comparable to PTFE in corrosion and heat resistance.
  • Integrated sensor design that simplifies calibration with standard solutions.
  • pH glass electrode and junction replaceable individually.
  • Pt1000 temperature compensation sensor built in.
  • Wetted materials include PPS, glass, titanium or Hastelloy C, ceramics or PTFE, and FKM or FFKM seals.

PH8ERP-05-TN-N-E specifications

Parameter Value
Measuring range pH 2 to 12
Measuring temperature -5 to 80 C
Pressure Atmospheric to 50 kPa
Temperature sensor Pt1000
Cable 5 m (chlorinated polyethylene rubber sheath)
Solution ground Titanium (TN)
Measuring system E for FLXA402, FLXA402T, PH202, FLXA202, FLXA21
Weight About 0.4 kg with 3 m cable
Optional calibration data /CAL, valid 6 months after manufacture

How PH8ERP-05-TN-N-E differs from PH8EFP

There are four numeric differences. The range is 2 to 12 against 0 to 14. The maximum temperature is 80 C against 105 C. The pressure limit is 50 kPa against 10 kPa for the general tank (or 500 kPa with the medium-pressure tank). And the supply of reference electrolyte is by hand rather than by tank. In return, PH8ERP-05-TN-N-E has a shorter ordering string, no tube to route, and a lighter installation.

Choosing between refillable and filling types

The PH8 range offers two reference philosophies. In the refillable type, PH8ERP-05-TN-N-E, the reference chamber is a closed volume that you fill with KCl solution and top up at maintenance intervals. In the filling type, PH8EFP, the chamber is connected to a reserve tank that tops up continuously. The refillable design is simpler, lighter, has no tube to be damaged or blocked, and is easier to carry in a service kit. It is the better answer in clean, mild, atmospheric tanks where the process pressure is low and the temperature stays within 80 C.

What you give up is range and pressure margin. The datasheet limits the refillable pH sensor to pH 2 to 12, -5 to 80 C and 50 kPa, while the filling type reaches pH 0 to 14 and 105 C. If your process has acid cleaning cycles, hot washdowns or strongly alkaline dosing, the broader window of the filling type is a safer buy. If your process is a municipal effluent tank, a cooling loop or a pool, the refillable sensor with its lower complexity is usually all that is needed.

Weight and handling also differ: the sensor alone is about 0.4 kg with a 3 m cable, and there is no 0.3 kg tank to mount. That matters on floating holders such as PB350G and PB360G, where the buoyancy and balance of the assembly are designed for a limited load.

Where to use it

Use the refillable sensor on cooling-tower blowdown, clean-water neutralisation, municipal wastewater, pool and potable water. In Omani plants with moderate chemistry and accessible sensors, it is the economical choice. Avoid it where the pH can go below 2 or above 12 for long periods, or the liquid is hot.

Holders

Table 1 of the datasheet gives the temperature limits by holder: guide pipe PH8HG in PVC to 50 C and in PP to 80 C; submersion PH8HS, flow-through PH8HF in stainless steel and suspension HH350G up to 80 C; floats PB350G and PB360G up to 50 C. A stainless steel holder is advised for solutions of pH 3 or more acidic. Choose the holder before the sensor, because it limits the process temperature.

Installation

Fill the reference chamber with KCl before first use, install the sensor tip-down at a slight angle so the junction is wet, and connect the cable to the analyser or through a terminal box. Calibrate with two buffers. Keep the cable and the sensor out of strong direct sunlight and avoid freezing. For PH8ERP-05-TN-N-E the 5 m cable carries the glass, reference, temperature and ground connections to the analyser, and the E measuring system fixes the termination style that the FLXA402, FLXA402T, PH202, FLXA202 and FLXA21 expect. Do not coil excess cable tightly near the sensor, and keep the cable away from motor leads and variable-speed drives to avoid noise on the high-impedance glass signal. After wiring, check the temperature reading against a thermometer before accepting the pH calibration, since a wrong temperature distorts compensation.

Maintenance

Check and refill the KCl at intervals, clean the glass and junction, and replace worn glass or junction parts individually. Recalibrate after each refill. When PH8ERP-05-TN-N-E comes back from storage, check that the reference chamber still holds KCl without crystals, rinse the glass with clean water, and soak the tip in buffer or tap water for a while before calibration. Record the date of each KCl refill, the buffer values and the slope, because the history helps decide whether a drifting reading comes from the glass, the junction or the electrolyte. Keep one spare sensor and a bottle of KCl solution in stock for each critical loop, as the sensor is the consumable part of the measuring chain and the analyser itself rarely needs attention.

Documents and quotation

The datasheet for PH8ERP-05-TN-N-E is attached. Send your RFQ to Seven Star LLC with the part number PH8ERP-05-TN-N-E, quantity and delivery location.

Other Models in the PH8 Range

Seven Star LLC supplies models from the PH8 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Yokogawa PH8EFP-05-TN-TT1-N-E KCl Filling pH SensorLiquid Analysis SensorsView details
Yokogawa PH8ERP-05-TN-N-E KCl Refillable pH SensorLiquid Analysis SensorsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Yokogawa PH8ERP-05-TN-N-E KCl Refillable pH Sensor Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa PH8ERP-05-TN-N-E KCl Refillable pH Sensor

Answers from our engineering team on installation, compatibility and integration.

01What pH range does PH8ERP-05-TN-N-E measure?
pH 2 to 12, with a measuring temperature of -5 to 80 C and a pressure from atmospheric up to 50 kPa. For pH 0 to 14 and up to 105 C use the PH8EFP filling type.
02Does PH8ERP-05-TN-N-E need a KCl tank?
No. It is the refillable type, so the reference chamber is refilled by hand and no reserve tank or tube is attached, which is why the code has no TT letters.
03How is PH8ERP-05-TN-N-E coded for the analyser?
The E measuring system suits FLXA402, FLXA402T, PH202, FLXA202 and FLXA21, with a cable that carries pin or terminal marks as stated in the datasheet. F is for FLXA202 and FLXA21 only.
04How heavy is PH8ERP-05-TN-N-E?
About 0.4 kg with a 3 m cable, and about 0.6 kg when supplied with a 3 m Variopin cable, so a 5 m cable adds slightly to that.
05What are the temperature limits with holders for PH8ERP-05-TN-N-E?
Between -5 and 50 C with a PVC guide pipe or float, and up to 80 C with polypropylene or stainless holders, as listed in Table 1 of the datasheet.