Hanna HI1048B pH Electrode with Clogging Prevention System (CPS) and BNC Connector overview

Hanna Instruments HI1048B is the part number of the pH Electrode with Clogging Prevention System (CPS) and BNC Connector. This page summarises what the maker publishes for HI1048B, so that maintenance teams, laboratory managers and procurement staff in Oman and the GCC can check the key parameters before sending a request for quotation. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Every figure below comes from the published product information and should be confirmed against the current documentation for your instrument and application.

A pH electrode converts the hydrogen ion activity of a sample into a small voltage that a meter, controller or transmitter turns into a pH reading. The glass membrane, the reference system and the junction all influence how fast, stable and repeatable that reading is, which is why the exact model matters when an installed instrument is repaired. Probes and electrodes are consumables: they age with use, so buyers often search for the exact order code such as HI1048B to replace a unit on an installed meter without changing the measuring method that was validated on site.

Key features of HI1048B

  • Described by the maker as: pH electrode with CPS™ (Clogging Prevention System).
  • Body material: glass.
  • Connection: BNC.
  • Measuring range: pH: 0 to 12.
  • Operating temperature: -5 to 60°C (23 to 140°F).
  • Electrolyte: KCl 3.5M.
  • Junction and flow rate: CPSTM.
  • Maximum pressure: 0.1 bar.
  • Cable: 7-pole 1 m (3.3′).
  • Recommended use: wine, must, juice.

Technical specifications of HI1048B

The table lists the values printed by the manufacturer for HI1048B. Entries that the maker does not publish have been left out instead of estimated.

Parameter Value
Part number Hanna HI1048B
Description pH electrode with CPS™ (Clogging Prevention System)
Reference double, Ag/AgCl
Junction / flow rate CPSTM
Electrolyte KCl 3.5M
Maximum pressure 0.1 bar
Measuring range pH: 0 to 12
Operating temperature -5 to 60°C (23 to 140°F)
Tip shape dome (dia: 8 mm)
Temperature sensor DIN model only
Built-in amplifier DIN model only
Body material glass
Cable 7-pole 1 m (3.3′)
Connection BNC
Recommended use wine, must, juice

Reading the HI1048B data

For a pH electrode the operating temperature and the pressure limit define where the sensor can be installed, and the junction type decides how well it copes with dirty, viscous or low conductivity samples. Hanna HI1048B is stated for -5 to 60°C (23 to 140°F) and for wine, must, juice. Check these against the process before choosing between similar-looking models in the same family.

Typical applications of HI1048B in Oman and the GCC

Water quality and process chemistry measurements are routine in the region. In oil and gas facilities the water laboratory checks boiler feed, produced water treatment, cooling water and effluent. Utilities and desalination plants monitor raw water, product water and chemical dosing steps. Municipal wastewater works, food and beverage plants and general manufacturing use similar sensors for quality control. The maker lists the following recommended use for HI1048B: wine, must, juice. Hot ambient conditions make careful storage and regular calibration particularly important, because dry or overheated sensing elements age quickly.

Selection and compatibility notes for HI1048B

Before ordering HI1048B, confirm three points. First, the connector: the table shows BNC, and it must match the meter input, because BNC, DIN, quick connect DIN, banana and 3.5 mm styles are not interchangeable. Second, the sample: compare the temperature and pressure limits and the body material with your process. Third, the measuring task: models in the same family differ in tip shape, junction, electrolyte and amplifier, so a similar looking code can behave differently. If you are replacing an existing electrode, quote the code printed on the old one together with the meter model, and mention if an alternative is acceptable.

Installation and commissioning of HI1048B

Remove the protective cap or soaking bottle if one is fitted, rinse the sensor with clean water and connect it to the instrument before switching it on. Calibrate with fresh standards that bracket the expected values, using the procedure of the meter in use, and note the slope or offset after commissioning. For HI1048B keep the cable away from power cables and motors, and do not bend the coaxial or multi-pole cable sharply, since cable damage is a frequent source of unstable readings.

Maintenance and storage for HI1048B

Keep sensing elements wet in the storage or soaking solution recommended by the maker, clean them with a suitable cleaning solution when the response slows, and replace the sensor when calibration can no longer be achieved. Rinse between samples and avoid touching glass or metal surfaces. Record the date of installation and the calibration results so the working life of HI1048B in your application is known, and keep one spare of the exact code in a cool, clean store for planned outages.

Good measurement practice for sensors of this type

Reliable results depend as much on routine as on hardware. Use fresh calibration standards, store opened bottles tightly closed, and discard standards that have been contaminated by dipping a wet sensor. Allow the reading to stabilise before accepting a value, because a drifting display usually means the sensor has not reached equilibrium with the sample or the temperature. Record the sample temperature, since most chemical measurements change with it. In hot climates samples left in a vehicle can warm quickly, so measure on site wherever possible and keep sensors out of direct sun. When a sensor shows a slow response, a low slope, a large offset or noisy readings, clean it, recalibrate, and only then consider replacement. Keep a simple log for each measuring point that lists the sensor code, installation date, cleaning dates and calibration results. Such a log makes it easy to see whether a failure is caused by the sample, by handling or by ordinary ageing, and it supports audits in laboratories that follow quality systems. Training operators to rinse, blot and store sensors correctly is usually the cheapest way to extend sensor life and to reduce repeat purchases.

Related products and ordering notes for HI1048B

Hanna Instruments offers many electrodes that differ only by connector, body material or junction, so the part number is the only reliable identifier. Alongside HI1048B we can quote related buffers, storage and cleaning solutions, reference electrodes and meters when you are reviewing a whole measuring point. Availability and lead time are confirmed per request, and no price is shown on this page.

Frequently asked points about HI1048B

  • What is HI1048B? It is the part number of the pH Electrode with Clogging Prevention System (CPS) and BNC Connector.
  • Which connector does it use? BNC.
  • What is the stated temperature range? -5 to 60°C (23 to 140°F).
  • How do I order? Send the RFQ with the part number HI1048B and the required quantity.

Documents and quotation

The manufacturer product page and manual set for HI1048B carry the complete technical information, and we can share the available documentation with the quotation. To request a quotation, send your RFQ with the part number HI1048B, the quantity and the delivery location in Oman or the GCC. Please add the meter model it will be used with so we can check the connector.

Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Hanna Instruments is a maker of analytical instruments for water and liquid testing, founded in 1978 in the Padua area of Italy by Oscar and Anna Nardo. Its early breakthrough was the pHep, an affordable pocket-sized pH tester. The company is now led by the founders' children, Martino and Pamela Nardo, with its headquarters in Woonsocket, Rhode Island, and offers more than 3,000 products.

Seven Star LLC is an independent supplier in Muscat. We list Hanna instruments for water, wastewater and laboratory users in Oman and the GCC.

Hanna Instruments company profile

Founded 1978, near Padua, Italy, by Oscar and Anna Nardo
Headquarters Woonsocket, Rhode Island, USA
Leadership Martino Nardo and Pamela Nardo
Early product The pHep pocket pH tester
Product families pHep and HI98 waterproof testers, edge benchtop meters, HI83 multiparameter photometers, Checker HC handheld colorimeters, HI931 and HI932 titrators, process controllers, reagents and calibration buffers

Hanna product series

Portable meters include the HI98190 pH and ORP meter, the HI98192 EC, TDS and salinity meter, the HI98193 dissolved oxygen and BOD meter, the HI98199 pH, EC and DO meter and the HI9829 multiparameter water quality meter.

The HI98703 is an EPA compliant portable turbidity meter, the HI97711 a free and total chlorine photometer and the HI83414 a benchtop turbidity and chlorine meter.

Waterproof portable meters such as the HI98190 and HI98192 suit field use, with automatic temperature compensation and GLP data for audits. Turbidity measurement with the HI98703 follows EPA method 180.1, and the HI97711 photometer measures free and total chlorine for disinfection control.

Where Hanna instruments are used

Drinking water and desalination plants, wastewater treatment, environmental field surveys, aquaculture, cooling water and quality control labs.

Hanna Instruments products we list

Family Examples
Portable Test & Measurement Hanna HI97711 Free and Total Chlorine Po…, Hanna HI98190 Waterproof Portable pH and…, Hanna HI98192 Waterproof Portable EC, Hanna HI98193 Waterproof Portable Dissol…, Hanna HI98199 Portable pH, Hanna HI9829 Multiparameter Water Qualit…, Hanna HI98703 Portable Turbidity Meter

Ordering Hanna instruments: what we need

Send the model, the parameters and ranges, the probe and cable length and any reagents or calibration solutions required.

Facts checked against Hanna Instruments' own company story and City of Woonsocket business profile, October 2026.

FAQ

Questions about the Hanna Instruments HI1048B pH electrode

Answers from our engineering team on installation, compatibility and integration.

01What is Hanna Instruments HI1048B?
HI1048B is the part number of the pH Electrode with Clogging Prevention System (CPS) and BNC Connector, as listed by the manufacturer.
02What connector does HI1048B use?
The manufacturer lists the connection as BNC.
03What temperature range is stated for HI1048B?
The manufacturer states -5 to 60°C (23 to 140°F) for this item.
04What is HI1048B recommended for?
The maker lists the following use: wine, must, juice.
05How do I request a quote for HI1048B?