Brand: Rosemount
Rosemount 00305-1000-0001 305 Module Sensor Guard
Description
Rosemount 00305-1000-0001 module sensor guard, set of five
Rosemount 00305-1000-0001 is the coplanar module sensor guard for the Rosemount 305 integral manifold system, sold as a set of five. The Rosemount Manifold Solutions datasheet explains its job in one sentence: a sensor module guard protects the transmitter process isolating diaphragms, and it should be used whenever the transmitter is removed from the integral manifold. The isolating diaphragms are thin metal membranes on the underside of the coplanar sensor module, and a scratch or dent from a bench or a tool can ruin the measurement.
That is why the guard appears in the spare parts list of the 305 manifold, in both the traditional-style and coplanar-style columns under the same number.
Datasheet facts
| Parameter | Value |
|---|---|
| Part number | 00305-1000-0001 |
| Description | Coplanar module sensor guard |
| Quantity per pack | 5 (set of 5) |
| Applies to | Rosemount 305 integral manifold (coplanar style and traditional style columns of the spare parts list) |
| Purpose | Protect transmitter process isolating diaphragms when the transmitter is removed from the manifold |
| Related O-ring sets | 03031-0234-0001 glass-filled PTFE, 03031-0234-0002 graphite-filled PTFE, set of 12 |
| Related bolt kits | 03031-0311-0001 CS, 03031-0311-0002 SST, 03031-0311-0003 A193 B7M, set of 4 |
| Related drain/vent | 01151-0028-0012 316 SST, 01151-0028-0013 Alloy C-276 |
| Cold temperature manifolds | CW1 minus 67 deg F (minus 55 deg C), BR6 minus 76 deg F (minus 60 deg C) |
What makes 00305-1000-0001 different from the other 305 spares
The spare parts list for the 305 manifold includes mounting brackets, bolt kits, O-rings, drain and vent valves and the sensor guard. The first four groups are parts of the manifold joint: they hold, seal or bleed the assembly. 00305-1000-0001 stands alone because it is a protective cover for the transmitter alone, used only while the transmitter is off the manifold, such as during calibration, shipment or manifold replacement. It is also the only item in the list sold in a pack of five, so one order can protect a batch of transmitters.
When to use the guard
- Whenever a 3051 coplanar transmitter is removed from a 305 manifold for bench calibration or repair.
- When transmitters are stored as spares in the instrument workshop.
- During transport between site and workshop in Muscat, Sohar, Duqm or Salalah, where vibration may rattle the module.
- During a manifold exchange that requires the transmitter to sit free for a while.
- When a plant is commissioned in phases and some transmitters are mounted after the manifolds have been tested.
A single missing guard can mean a replaced transmitter module; the guard is cheap insurance.
Using the guard correctly
Place 00305-1000-0001 over the process face of the module as soon as the manifold is removed, before the transmitter is set down. Check the isolating diaphragms for scratches first. Never use the guard as a leverage point. Keep the five-pack in the toolkit used for calibration, and re-fit a guard before putting the transmitter back in a stores bin. When the manifold is refitted, remove the guard, inspect the O-rings listed in the spares table, replace them if they are flattened, and tighten the bolts in the sequence given by the transmitter manual.
The datasheet’s options section adds two finishing choices that matter to a store keeper. Option P2 cleaning for special services minimises process contaminants and prepares wetted surfaces according to ASTM G93-96, and option SG sour gas designates materials of construction that comply with NACE MR0175/ISO 15156 for sour oil field production, with selected materials also conforming to NACE MR0103/ISO 17495 for sour refining. If the transmitter and manifold went through such preparation, keep the guard in the original clean packing so it does not contaminate the cleaned surface. Take care to handle the clean parts with gloves.
Where the 305 manifold fits in the Rosemount range
The 305 coplanar manifold assembles directly to the transmitter, removing the need for a flange, and is factory assembled, leak tested and calibrated when ordered with the transmitter. The datasheet describes block-and-bleed, two-, three- and five-valve configurations, and options for NACE-compliant materials. The sibling 306 in-line manifold and 304 conventional manifold serve in-line pressure transmitters and flanged transmitters respectively and use different spares.
Another reason to protect the module is the way the 305 is sold. When a Rosemount manifold is ordered together with a Rosemount pressure transmitter, the datasheet says the customer receives a fully assembled, calibrated and leak-tested solution that is ready for out-of-the-box installation. Calibration data belongs to the transmitter, and a damaged diaphragm invalidates it. The integral design is also described as flangeless, reducing weight, space and leak points compared with a conventional flange and manifold arrangement, and the sensor guard is the accessory that keeps this compact assembly serviceable in the field without risk to the sensing element.
Handling and storage
Store guards clean and dry. Do not stack heavy objects on them. If a guard is damaged or has swollen from chemical exposure, discard it rather than reusing it. Mark the transmitters in the store with a coloured tag when their guard is fitted, so that nobody installs a transmitter with the guard still in place.
Plants that keep a calibration bench should also keep the matching bolt kits (set of 4) and drain or vent valves from the same spare parts table at hand, since the guard is used when those are removed. A well-organised kit per transmitter reduces rework during turnarounds.
Documents and quotation
The Rosemount Manifold Solutions datasheet that lists 00305-1000-0001 in the spare parts section is attached. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. To obtain a quotation, send an RFQ with part number 00305-1000-0001, the quantity of five-packs, and your delivery location in Oman or the GCC.
Other Models in the Rosemount Manifold Spares Range
Seven Star LLC supplies models from the Rosemount Manifold Spares range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Rosemount 00305-1000-0001 305 Module Sensor Guard | Instrument Valves & Fittings | You are viewing this model |
| Rosemount 01166-8005-0001 304 Heavy Duty Bracket 316 SST | Instrument Valves & Fittings | View details |
Datasheets & Documents
- Datasheet Rosemount 00305-1000-0001 305 Module Sensor Guard Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile
Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments
Milestones
1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.
Rosemount products we list
FamilyModelsTypical use
Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams
Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.
FAQ
Questions about the Rosemount 00305-1000-0001 305 Module Sensor Guard
Answers from our engineering team on installation, compatibility and integration.
01What is Rosemount 00305-1000-0001?
It is a coplanar module sensor guard sold as a set of five, listed in the spare parts of the Rosemount 305 integral manifold.
02When must the guard be used?
The datasheet says it should be used whenever the transmitter is removed from the integral manifold, to protect the process isolating diaphragms.
03How many guards are in one pack?
The spare parts table lists the sensor guard as a set of five under 00305-1000-0001.
04Is the same part used for coplanar and traditional 305 styles?
Yes. The 305 spare parts table shows 00305-1000-0001 in both the traditional-style and coplanar-style columns.
05Which O-ring sets accompany the 305 manifold?
03031-0234-0001 is glass-filled PTFE and 03031-0234-0002 is graphite-filled PTFE, each a set of 12.